Regardless of the setting our Sharp R-1870 microwave/convection oven stops at 59 seconds. You can restart the cooking process by pushing the start button but will only go for another 59 seconds.

Posted by on

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Sharp Master
  • 8,820 Answers

Wow. I just read something ridiculous!

Well, never mind that, here's your solution:

This is a common problem in one of the damper-related components, most likely the switch, but it may also be the motor or the damper door.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample photo for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded it to our site here and here to help you. You will need the free Adobe Reader to view or print it.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Posted on Jan 29, 2009

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Sharp Master
  • 5,568 Answers

There is a settable counter or section of a custom IC that has failed and you will probably have to replace the entire board since most parts are robot installed and near impossible to replace by hand any more.
You may be disappointed when you learn the replacement board cost; they frequently make a repair economically foolish.
Pulling the plug and examining the board should let you find the part number for it so yu can either search on line or call Sharp to find the cost.   

Posted on Jan 26, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Sharp microwave r1870 only runs for 59 seconds


If it consistently runs for exactly 59 seconds, and shuts off, it's probably the control panel.

If it runs approximately that length of time, you might have a defective thermal protector on the magnetron, or the magnetron is running too warm for some reason.

Mar 24, 2016 | Sharp R-1870 Convection/Microwave Oven

1 Answer

Microwave oven stops after 59 seconds


This is a problem in one of the damper-related components, either the switch or motor or the damper door may be binding.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp-made models stop after 59 seconds.

See the attached sample drawing for a typical damper assembly.

If a switch is all you need, we offer a universal type for only $7.50 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

b27054b.jpg

Oct 06, 2011 | Sharp R-1870 Convection/Microwave Oven

1 Answer

My Sharp micro will stay on for 59 seconds and shut off no matter how long the timmer is set. Sharp model r 1870 It does this every time it is used . The control board has been replaced.


This is not a problem on the board, it is a problem in one of the damper-related components, either the switch or motor or the damper door may be binding.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample drawing for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded them to our site here and here.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Dec 17, 2010 | Sharp R-1870 Convection/Microwave Oven

1 Answer

Sharp convection microwave R-1870 runs about one minute and shuts off. damper Motor switch?


This is a problem in one of the damper-related components, either the switch or motor or the damper door may be binding.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample drawing for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded it to our site here and here to help you.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Dec 17, 2010 | Sharp R-1870 Convection/Microwave Oven

1 Answer

My sharp R1870 microwave/convestion oven turns


This is a problem in one of the damper-related components, either the switch or motor or the damper door may be binding.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample drawing for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded it to our site here and here to help you.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

William E. Miller
prototech@usa.net
http://www.microwavedisplay.com



damper.jpgdamper.jpg

Apr 26, 2010 | Sharp R-1870 Convection/Microwave Oven

1 Answer

The microwave will only work for 59 seconds then it stops. It is working but only for 59 seconds. I am not sure about the convection oven was afraid to try it. The unit is in our fifth wheel RV. I can heat...


This is a problem in one of the damper-related components, either the switch or motor or the damper door may be binding.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample drawing for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded them to our site here and here to help you.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

damper.jpgdamper.jpg

Apr 18, 2010 | Sharp R-1870 Convection/Microwave Oven

3 Answers

Sharp Carousel II Convection Microvave R-3850


My sharp microwave convection oven (R-1870) runs for 59 seconds and stops. If I push start it runs for another 59 seconds and stops. How can this be fixedd?

Aug 29, 2009 | Sharp R-1870 Convection/Microwave Oven

1 Answer

Timer shuts off


there was a similar problem posted on your site that solved my problem.

Aug 18, 2009 | Sharp R-1870 Convection/Microwave Oven

1 Answer

Sharp model R-1870 Carosel quits cooking at 59 seconds


This is a problem in one of the damper-related components, most likely the switch, but it may also be the motor or the damper door.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample photo for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded it to our site here and here to help you. You will need the free Adobe Reader to view or print it.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Jan 26, 2009 | Sharp R-1480 Microwave Oven

Not finding what you are looking for?
Sharp R-1480 Microwave Oven Logo

365 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sharp Microwave Ovens Experts

William Miller
William Miller

Level 3 Expert

8820 Answers

Devabhakthuni...
Devabhakthuni...

Level 2 Expert

224 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17129 Answers

Are you a Sharp Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...