Lg split system ch 05 error outside fan not working

Posted by on

3 Answers

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Contributor
  • 30 Answers

Solution # 1, Check Condensor Fan Motor Capacitor 4uf or MFD
# 2, Check Motor Windings
# 3, Check Relay OR Defination Contactor
# 4, Check Connection Terminals

hope will help u 2 solve this

GOOD LUCK

Posted on Feb 16, 2009

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

LG split system CH24

Posted on Dec 07, 2010

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

Remote will not bring unit on . have changed battery

Posted on Dec 17, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

What does the code on the screen mean flashes between ch and 05 ?


CH 5 on these units indicates a communications error between the indoor and outdoor units. Generally, it will require a replacement outdoor board assembly to repair it. Lookup LG parts on the internet or ring them for your nearest Agent or parts. 800 243-0000

Oct 15, 2016 | LG Art Cool LA181CNW Split System Air...

1 Answer

How to fix LG error code ch 23


there is a problem with a sensor ,but it must to change both(because are 2 senzor )even is broken just one.this senzors are locate in outside unit.

Nov 21, 2013 | LG LSC091PMA Split System Air Conditioner

2 Answers

Error code ch 05


Comms Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4

Feb 03, 2011 | LG Art Cool LA181CNW Split System Air...

1 Answer

LG air conditioner 24awn error code message Ch 6 inside fan runs outside unit not working


CH-06 REFERS Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. if not replace sensor. THANKS.

Dec 13, 2010 | LG Art Cool LA121HNP Split System Air...

1 Answer

What is error code ch o5


CH-05 Communications Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4

Oct 06, 2010 | LG LSC183VMA Split System Air Conditioner

1 Answer

LG air condotioner with a CH5 error code


CH-05-Comms Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4

Jul 27, 2010 | LG L1004R Air Conditioner

1 Answer

Error Ch 26


1.check indoor unit wiring.
2 check cirkit board
3 check selector switch

Mar 25, 2008 | LG LSC183VMA Split System Air Conditioner

2 Answers

Error ch 5


check all wiring and connections - ch 5 is a communication error between the indoor unit and the outdoor unit......

Dec 09, 2007 | LG LSC183VMA Split System Air Conditioner

Not finding what you are looking for?
LG LS-L1210CL Mini Split Air Conditioner Logo

2,430 people viewed this question

Ask a Question

Usually answered in minutes!

Top LG Air Conditioners Experts

Donald DCruz
Donald DCruz

Level 3 Expert

17129 Answers

Tim Whalen

Level 3 Expert

3056 Answers

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Are you a LG Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...