1) Clock motor has gone bad, but replacement clock motors are no longer made.
Copy following link for Paragon resources:
http://waterheatertimer.org/Paragon-timers-and-manuals.html

2) Paragon is not making parts or replacement motors.
4007-41 is 240Volt timer, replace timer with Intermatic T104
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html

3) Crossover wiring from Paragon 4004-71 to Intermatic T104:
Paragon 1 to Intermatic 1
Paragon 2 to Intermatic 2
Paragon 3 to Intermatic 4
Paragon 4 to Intermatic 3
Intermatic terminal A is generally not used for 240Volt

4) Add a comment if needed

Posted on Jan 17, 2013

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
protek480
  • 1714 Answers

SOURCE: Intermatic T101 does not turn on using the

There are two different trippers. 'On' and 'off'. The off will not turn it on. Get an 'on' tripper.

Posted on Jun 26, 2009

  • 1114 Answers

SOURCE: The Trippers on my Paragon Electric timer are

The following Web Site lists tripper pins for Paragon timers. I don't know if your model is listed, but give it a try.
I hope this helps!
http://www.icca.invensys.com/paragon/parts_accessories.htm

Posted on Aug 15, 2009

  • 52 Answers

SOURCE: Need tripper pins for AMF Paragon Timer Model 7218

Go to electricalexpeditors.com for replacements.

Posted on Dec 30, 2009

  • 52 Answers

SOURCE: Need trippers for Paragon #4004-20

send inquiry to electricalexpeditors.com
we sell replacement parts

Posted on Feb 02, 2010

  • 52 Answers

SOURCE: I need to find Paragon timer model P101 parts ie.

call 1888 782 6086 www.electricalexpeditos.com

Posted on Jun 25, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My parafon 4001-0 is coming on at the wrong time..i have one set of trippers and they are correctly, and now have turned off the breaker to shut the lgihts off. I don't know what to do


Is the dial rotating and keeping good time?
Are the X2772 trippers worn down?
Does the manual override lever turn load on-off.

You can buy replacement trippers online.
Otherwise if the clock dial is slow, then clock motor is bad, and you need to replace timer.
http://waterheatertimer.org/Paragon-timers-and-manuals.html

Replace the 4001-1 120Volt timer with Intermatic T101 timer.
Crossover wiring is as follows.
Paragon terminal 1 => Intermatic 1
Paragon 2 => Intermatic 2
Paragon 3 => Intermatic A
Intermatic timers are easily repairable and adaptable for various voltages and different countries by changing clock motors
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Oct 03, 2012 | Hardware & Accessories

1 Answer

4003-0s clock wont count does turn to show time or swicth on lights


1) If timer dial is not rotating, then the clock motor has gone bad.
New paragon clock motors are not sold anywhere I know about.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

2) If dial rotates on time, but trippers don't work, then buy new X2772 trippers.

3) Buy new 120Volt 4003-00 timer at Southside for $86:
http://www.southsidecontrol.com/acatalog/Products_Paragon_4003_0_24_Hour_Time_Clock_4003_00_3823.html

4) BuildingHVAC sells 4003-00 timer for $56.00
http://www.buildinghvac.com/acatalog/Products_Paragon_4003_0_24_Hour_Time_Clock_4003_00_3709.html

Aug 04, 2011 | Paragon Amf 7008-00 Timer 7 Day 120 Volt...

1 Answer

My model 1015-00RS timer comes on when it's set to be off at certain times, I push big dial down and it goes off, but then the next day it does the same thing, is there ajustment for fine tuning the...


I might not understand the problem correctly.

Open following link to identify timer:
http://waterheatertimer.org/Paragon-timers-and-manuals.html#1015

From your post, the large dial on your timer can be pushed up and down?
Or are the trippers popping up?

The dial is supposed to rotate clockwise during regular operation, and can be manually rotated either direction to set current time, but dial should not move in and out or up and down.

If the trippers are worn, then they are built in. The problem is that Paragon is no longer making parts and does not support 1015 timers.
It's possible the trippers might be getting pushed up if the on-off mechanism needs lubrication.

May 2011, Patriot stills sells the 1015-00RS for $187
http://www.patriot-supply.com/products/manufacturer_detail.cfm?manu_id=191
Intermatic 120Volt-480 Volt crossover product is T1975 (advantage is replaceable trippers, motor and switch)
Grainger sells T1975 for $126
http://www.grainger.com/Grainger/INTERMATIC-Indoor-Multi-Operation-Timer-6X761?cm_mmc=GoogleBase-_-Electrical-_-Timers-_-6X761&ci_src=14110944&ci_sku=6X761

Crossover wiring for 120Volt application:
All wires on Paragon 1 to Intermatic Clock
Paragon 2 to Intermatic Com
Paragon 5 to Intermatic NO
If there are wires on Paragon 6 to Intermatic NC

Upvote the help.
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

May 30, 2011 | Paragon 1015-00RS Indoor Multi Operation...

1 Answer

I have a Paragon 42013-20 timer, no longer manufactured. I need to find replacement trippers. Thanks for any assistance.


I cannot find a brochure showing specific paragon tripper numbers.

You have Paragon 42013-20 timer, DPST 10Amp 2Hp, Nema3 indoor-outdoor, 24 hour-timer with 48 trippers built into timer dial.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#42000
If trippers are worn out, you can possibly work-around by rotating dial 12 hours so fresh trippers can be accessed using same dial. The only difference is nighttime hours shown on clock face will now represent daytime hours.

Intermatic Cross reference shows replacement timer is T1976R
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx
http://www.intermatic.com/~/media/files/intermatic/catalog/pages/014.ashx
http://www.intermatic.com/products/timers/mechanical%20time%20switches/24%20hour%20dial%20with%20skipper.aspx
http://www.drillspot.com/products/648036/intermatic_t1976r_24_hour_electromechanical_timer

Difference between your paragon timer and suggested intermatic, it that Paragon throws both terminals at same time, while Intermatic has alternating NO NC terminals.

Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you via e-mail or phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Feb 23, 2011 | Paragon 42013-20 Timer

1 Answer

Have a paragon amf 4004-71 timer it runs constantly


Paragon 4004-71 is 240Volt timer
http://waterheatertimer.org/Paragon-timers-and-manuals.html#Paragon4000

1) If your trippers are worn down, the timer will not turn on and off
Google search for X2772 trippers.
2) If your timer dial is not rotating, then timer clock motor is bad.

3) According to e-mail I received from Paragon Nov 2010, Paragon is no longer making timers and parts, except for their line of defrost timers.
4004-71 is not a defrost timer, so it is no longer being made according to Paragon representative.

4) To change timer brands: Intermatic cross reference shows Paragon 4004-71 can be replaced with Intermatic T-104 timer.
Intermatic cross reference link:
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx
Lowes and Grainger and many other outlet sell T-104 240V timer.

5) How to wire T-104
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html

Dec 15, 2010 | Woods Outdoor Photoelectric 24 Hour...

1 Answer

I need to read a manual. I can't get my timer to turn on my outdoor Christmas lights.


You posted under Paragon 4001 120Volt timer
If this is not your timer, look at next page to identify timer
Or add a comment
http://waterheatertimer.org/Paragon-timers-and-manuals.html

Paragon 4000 series manual
http://waterheatertimer.org/pdf/Paragon-4000-series.pdf

4000 series uses X2772 tripper
Clock dial rotates with passing time.
If you need more help, add a comment.

geno_3245_155.jpg

Dec 08, 2010 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

Have a 4003-00 Timer for a business park outdoor parking lot lights. I need to change hte tim to come on ~ can't find the book to tell me how to change this? Can you help?


ef74fbb.jpgParagon 4000 series is a mechanical dial timer

fb54fa2.jpg
Image explains general operation of timer
Attach Black tripper to dial at time you want lights to turn OFF
Attach Silver tripper to dial at time you want lights to turn ON
Minimum on-off period is 1-1/2 hours
Re-set dial after power outage.

The dial rotates with passing time
The timer takes the Paragon X2772 tripper
If tripper does not turn lights off-and-on, then you might need new trippers
If dial does not rotate, you might need new timer
If manual override does not work then check electricity

http://waterheatertimer.org/Paragon-timers-and-manuals.html#Paragon4000
If you need more information, add a comment below and I will respond.

Oct 27, 2010 | Paragon REPLACMENT MECHANISM 110V SPST -...

1 Answer

Jst bought the house and there is a paragon 4100-0 light timer how do you reset the on-off times to approx. 5 pm on and 11 pm off ?


Paragon 4000 series timers are traditional electro-mechanical timers.
The dial rotates around like a clock as time passes
Black and silver tripper pins on attached to outer edge of dial.
Black tripper is Off
Silver tripper is ON
The tripper pins encounter a lever.
The On tripper pushes lever one direction, the Off tripper pushes lever opposite direction
Click manual override to switch lights by hand

To set current time, lift and rotate dial until current time lines up with black pointer.
Set your trippers on the dial next to the On and Off times you want.
Set silver tripper at 5:oo
Set black tripper at 11:oo
Minimum set time is 1 hour

e62b9e8.jpgParagon 4000 series

If this is not the correct timer, answer back with a description and I'll check my files

Oct 24, 2010 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

How do i set timer to turn lights off and on


If I understand correctly, you have Intermatic electro-mechanical timer that has a yellow clock dial on front
And you want to set the timer to turn lights on and off
And your wiring is correct and the manual override turns the lights on-and-off correctly

To set timer:
Pull dial back toward you. Rotate clock dial until current time lines up with silver pointer.
On other brands of timer, you rotate dial until current time lines up with an arrow or the word 'time' located on lower right of clock dial
Timer has on-off trippers that fit outer edge of dial.
Intermatic trippers are labeled ON and OFF
Other brands of timer have dark and light-colored trippers >> I think the dark trippers on some brands are OFF

Place 'off' tripper when you want timer to turn off
Place 'on' tripper when you want timer to turn on
Turn on electricity and expect timer to run for 20 years
Dial has to be re-set to current time after power outage

http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html
http://waterheatertimer.org/Paragon-timers-and-manuals.html

Oct 20, 2010 | Intermatic & Indoor/Outdoor Rain Tight...

1 Answer

We have an AMF Paragon 4001 timer for the light outside our building. The light goes on lately at the wrong time. We want it to be on at 7:00pm and off and 5:00am but it goes on at 12:00 at noon.


To set paragon timer: Pull large round dial straight out towards you, then rotate dial until correct time is lined up with stationary 'pointer' on front of dial

Sep 08, 2010 | Paragon 4001-0G Defrost Timer

Not finding what you are looking for?
Hardware & Accessories Logo

Related Topics:

238 people viewed this question

Ask a Question

Usually answered in minutes!

Top Paragon Hardware & Accessories Experts

Gene Haynes

Level 3 Expert

5089 Answers

Steve

Level 3 Expert

3287 Answers

jdthefixer

Level 3 Expert

744 Answers

Are you a Paragon Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...