Hello here is the homepage:

http://downloadcenter.intel.com/SearchResult.aspx?lang=eng&ProductFamily=Desktop+Boards&ProductLine=Intel%C2%AE+865+Chipset+Family+Boards&ProductProduct=Intel%C2%AE+Desktop+Board+D865GVHZ


Here is a fault finder guide:

http://www.tomshardware.co.uk/forum/261145-13-perform-steps-posting-boot-video-problems

Try to add a graphic card on the mainboard, instead using the onboard graphic.
The power supply could also be failing.

Good luck

Posted on Jan 13, 2013

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The phone starts displaying a white screen and is not starting up. you have to remove the battery to turn it off.


Your phone's RAM memory cannot boost properly so you need to reformat your phone and install software to boost your RAM.

Jul 17, 2011 | Nokia 5800 XpressMusic Smartphone

1 Answer

How do I set the equalizer to my own custom settings on my RCA RS2635?


Hello
Press "Preset EQ" on the main unit, or "EQ" on the remote control to toggle among FLAT,ROCK,POP,JAZZ, CLASS. The display show the selection briefly. Press "Bass Boost" to turn ON/OFF boosting the bass frequency. OK.

Dec 03, 2010 | RCA RS2635 CD Shelf System

1 Answer

Smoking Vehicle After servicing.


Ther first code ECM-6805 TURBOCHARGER (TC) CONTROL VALVE DIAGNOSTIC TROUBLE CODE (DTC) INFORMATION If engine speed (RPM) is above 3500 rpm and the engine is operating at a high load, and if the boost pressure (from the boost pressure sensor) is higher than a designated value, which at maximum boost pressure is approximately 20kPa (2.9psi) above normal boost pressure, this is interpreted as a fault and diagnostic trouble code (DTC) ECM-6805 is stored. Condition reduced boost pressure Possible source * hoses between turbocharger (TC) and turbocharger (TC) control valve respectively turbocharger (TC) control valve and pressure servo are loose or are blocked/damaged * faulty turbocharger (TC) control valve * faulty boost pressure control (BPC) valve pressure servo * sticking boost pressure control (BPC) valve Condition * none ECM-6805 TURBOCHARGER (TC) CONTROL VALVE PRESSURE TOO HIGH - PERMANENT/INTERMITTENT FAULT Checking the hoses and turbocharger (TC) control valve Check that the hoses between the intake manifold, pressure regulator and turbocharger (TC) control valve are not trapped, blocked or damaged. Check the turbocharger (TC) control valve by activating it. Check the alignment of the boost pressure control (BPC) valve pressure servo and the boost pressure control (BPC) valve and that they are functioning correctly and not sticking according to See: Component Tests and General Diagnostics\Boost Pressure Regulator, Checking/Adjusting Verification Hint: After carrying out the repair, check that the fault has been remedied. * Ignition off. * Reinstall connectors, components etc. * Disconnect the VCT 2000 from the data link connector (DLC). * Test drive the car and check that high boost pressure is obtained. * Connect the VCT 2000 to the data link connector (DLC). NOTE: Do not switch off the ignition before the VCT 2000 has been connected and the boost pressure has been tested with the smart tool. Read the boost pressure fault status When the boost pressure has been tested the display should show that the diagnostic is complete. the second code Symptoms You will likely not notice any serious drivability problems, although there may be symptoms. Possible Solutions The simplest thing to do is to reset the code and see if it comes back. Then start with the cheapest, easiest repair procedures: Inspect for the following conditions: An incorrectly routed harness--Inspect the harness of the MAF sensor in order to verify that it is not routed too close to the following components: - The secondary ignition wires or coils - Any solenoids - Any relays - Any motors A low minimum air rate through the sensor bore may cause this DTC to set at idle or during deceleration. Inspect for any vacuum leaks downstream of the MAF sensor. A wide open throttle (WOT) acceleration from a stop should cause the MAF sensor g/s display on the scan tool to increase rapidly. This increase should be from 6-12 g/s at idle to 230 g/s or more at the time of the 1-2 shift. If the increase is not observed, inspect for a restriction in the induction system or the exhaust system. The barometric pressure (BARO) that is used in order to calculate the predicted MAF value is initially based on the MAP sensor at key ON. When the engine is running the MAP sensor value is continually updated near WOT. A skewed MAP sensor will cause the calculated MAF value to be inaccurate. The value shown for the MAP sensor display varies with the altitude. With the ignition ON and the engine OFF, 103 kPa is the approximate value near sea level. This value will decrease by approximately 3 kPa for every 305 meters (1,000 feet) of altitude. A high resistance on the ground circuit of the MAP sensor can cause this DTC to set. Any loss of vacuum to the MAP sensor can cause this DTC to set. the third code O2 sensor failure may not be displayed appropriatly

Jun 08, 2009 | 1997 Volkswagen Jetta

1 Answer

Nexel i885 backlight not working


I think what u might have 2 do is call the Boost costumer service and have them maybe restart the whole phone for u. Maybe if they were 2 restart ur phone it might work again

May 09, 2009 | Nextel BOOST i835g i835 LTD. ED UNLOCKED...

1 Answer

Every time I make a phone call My blackberry has a strange symbol


Hi,

The icon is an indicator for the Enhance Call Audio feature selected on the device. The Enhance Call Audio feature is designed to allow a user to adjust the sound quality over the earpiece of the device (e.g. Boost Bass or Boost Treble)

callscreen.jpg

To improve sound quality for all phone calls, complete the following steps:
  1. In the Phone application, display the menu and select Options.
  2. Click General Options.
  3. Change the Enhance Handset Call Audio or Enhance Headset Call Audio field.
  4. Display the menu and select Save.
To improve sound quality during a phone call, complete the following steps:

1. During a phone call, display the menu and select Enhance Call Audio.
2. Select Boost Bass, Boost Treble or Normal.

To review the different Selectable Phone Equalizers during a phone call, press the L key. The enhancement specific icons are displayed on the active call screen.

Feb 27, 2009 | AT&T Blackberry Curve 8300 Smartphone

1 Answer

My boost screen displays please wait to enter special code and its 8 digits


The phone is locked to your carrier. An unlock code must be entered to use the SIM of another carrier in the phone. Check with boost for an unlock code. There are also tons of unlock calculatrs out there, but be careful ... if the wrong code isentered too many times the phone will be permanently locked to boost.

Jan 26, 2008 | Cell Phones

1 Answer

Shows Dark


Many factors can affect the image quality of your pictures. If you are experiencing blurry images, please try adjusting the focus ring located around the lens. This will allow you to focus the camera image on objects at different distances. Also, make sure there is good lighting. Improving the lighting conditions can improve the image quality considerably.
Connection Issues:
If the image quality is poor while transmitting video over the Internet using video enabled programs such as MSN Messenger, Yahoo! or AOL Instant Messenger, your connection speed to the Internet directly affects the image quality of the transmitted video. Corporate LAN, DSL/cable modem connections will result in the best image quality experience, while dial-up connections may result in choppy and overall poor quality because of the slower connection speed. Even broadband connections such as DSL/cable modem may experience choppy video at times because of Internet traffic or slow upload speeds. If the image appears clearly in the camera software, most likely your Internet connection may be responsible for the poor image quality in your video program.
Changing Display Adapter Settings:
If you are still experiencing a distorted, fuzzy or grainy image, you may need to change the settings for your display adapter. For optimal image quality, please make sure the video display adapter is set to display at least 16-bit high color or higher. To change the color palette please perform the following steps:
  1. Click on "Start," "Settings," and "Control Panel."
  2. Double-click on the Display icon.
  3. Click on the tab labeled Settings.
  4. In the dialog box labeled Color Palette, verify the video mode is set to 16-bit (high color) or 24-bit (true color).
  5. Also, check with the manufacturer of the video card for updated video drivers.
Low Light Boost:
If you cannot do anything to improve the lighting situation, some Logitech video cameras have an option for "Low Light Boost." If there is an option for "Low Light Boost," try enabling the "Low Light Boost" in the QuickCam software. To do this:
  1. Open the QuickCam software.
  2. At the bottom right hand corner of the camera image box, click on the arrow next to the QuickCam icon.
  3. Choose "Advanced Camera Settings".
  4. Under the Image Enhancement box, place a check mark in the "Low Light Boost" option.
  5. If that does not improve the image quality, try adjusting the other image settings, such as contrast, saturation brightness, gain and white balance.
  6. Click OK when your are done.

Jan 13, 2008 | Logitech Quickcam Chat Webcam

Not finding what you are looking for?
Intel D865GVHZ Motherboard Logo

Related Topics:

24 people viewed this question

Ask a Question

Usually answered in minutes!

Top Intel Computers & Internet Experts

Tony

Level 3 Expert

2600 Answers

David
David

Level 3 Expert

778 Answers

vsri9

Level 2 Expert

73 Answers

Are you an Intel Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...