Question about Desa International Comfort Glow Infrared Vent-free Gas Space Heater

Open Question

Comfort glow 107888-03 pilot will not stay lit

Posted by Anonymous on

4 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 139 Answers

SOURCE: Have Model CGP30TB Copmfort Glow propane

sounds like an obstruction in pilot assembly.try using canned compressed air to blow directly into pilot. this technique is successful about 70%. if not,pilot assembly must be removed and cleaned thorougly

Posted on Sep 16, 2009

  • 279 Answers

SOURCE: The pilot on my Comfort Glow Gas Logs CLD3924PTA

You must have some kind of flame sensor and it sounds as though it is not working correctly. If the pilot lights and then goes off, I would look there first. Good luck...Lee

Posted on Nov 06, 2009

  • 30 Answers

SOURCE: pilot won't light

You may have to bleed some more air out of the system.

Your ODS pilot may be clogged with dust or lint and needs to be blown out with air(less than 30 psi).

Your regulator or gas valve may be faulty.

Posted on Mar 04, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

When I try to use my Thermolaire model SU402E, the pilot lights( and stays lit), but the main burner will NOT ignite.. any suggestions as to what could cause this if the pilot stays lit?


Bad igniter? When you 1st try it the gas valve will give enough gas that you would get the burner lit if the igniter was glowing red. If you're desperate you can light the igniter area w/ an aim n flame, but you definitely want to do that w/ caution and crank up your t-stat so the furnace stays on awhile Cuz you'll have to do it again for heat or buy an igniter($40 or so)

Jan 14, 2015 | Heating & Cooling

1 Answer

Dyna Glow pilot light will not stay lit.


there is a screw on the gas valve to adjust the pilot flame . It will be under a cap

Dec 09, 2009 | Dyna-Glo RMC-8001SS Heater

1 Answer

My husband and I recently purchased a house that has a Comfort Glow Vent-free Propane/LP gas compact fireplace 14,000 to 26,000 BTU/Hr with Thermostat. Model CGCFTP We need to light the pilot light and it...


Remove the small copper colores tubing going from the gas valve to the pilot assembly. Take it to a good hardware store that sells heaters and ask them for a new one.It is called a thermocouple.

Nov 18, 2009 | Desa International Heating & Cooling

1 Answer

The pilot on my Comfort Glow Gas Logs CLD3924PTA won't stay lit. Can anyone help me with this problem??? Thanks


You must have some kind of flame sensor and it sounds as though it is not working correctly. If the pilot lights and then goes off, I would look there first. Good luck...Lee

Nov 04, 2009 | Desa International Comfort Glow Infrared...

1 Answer

WE can get the pilot light lit but it will not stay on


You will need to check the pressure regulator for the gas.
It sounds like the gas pressure is to low to keep the pilot lit.

John

Oct 01, 2009 | Desa International Blower Glow Warm Wall...

1 Answer

I have a Comfort Glow propane heater connected a 20lb tank. The pilot has a hard time staying lite but when I do get it lite ang turn the hearter on low it will shut off in a minute or in some cases 20...


If you have a pilot, you have a thermocouple. I would start with the thermocouple. The thermocouple is supposed to be heated by the piolet and to keep the pilot gas on. If it is faulty, the pilot will quit and the heater will not reignite until you light it again. Good luck...Lee

Sep 21, 2009 | Desa International Comfort Glow Infrared...

1 Answer

Have Model CGP30TB Copmfort Glow propane heater. Pilot light won't stay lit. Flames also coming from what seem to be air vents just below flame on pilot light.


sounds like an obstruction in pilot assembly.try using canned compressed air to blow directly into pilot. this technique is successful about 70%. if not,pilot assembly must be removed and cleaned thorougly

Sep 10, 2009 | Desa International Comfort Glow Infrared...

1 Answer

Wont stay lit


If the pilot flame does not touch the thermocouple, the heater will do exactly what you describe.

Get a short piece of copper tubing that will fit snugly over the thermocouple and bend the short piece so that it is in the pilot flame.

Jan 21, 2009 | Heating & Cooling

Not finding what you are looking for?
Desa International Comfort Glow Infrared Vent-free Gas Space Heater Logo

Related Topics:

31 people viewed this question

Ask a Question

Usually answered in minutes!

Top Desa International Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1338 Answers

Bill Jordan

Level 2 Expert

372 Answers

David Spradling
David Spradling

Level 3 Expert

3543 Answers

Are you a Desa International Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...