Question about GE Profile Harmony DPGT750EC Electric Dryer

1 Answer

Dryer does not run

Dryer does not do anything when you push the start button.checked the button and ohms out ok when you push it in.Door button is ok also timer does not sound like it is working also...

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Expert
  • 67 Answers

The time my electric dryer acted like that, it turned out my door switch had gone bad.

Posted on Jan 22, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Won't start and on/off LED is out. Getting power to the transformer and 'some' voltage out. Thermostat checked and all is OK.


Electric dryer no start does nothing

Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.

CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.

NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.

If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings

Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.

Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.

https://www.youtube.com/watch?v=sTRP6kHqAFs
Hey GOD IS GOOD !!!! WHICH IS WHY MY ADVICE IS FREE





What to Test When Whirlpool or Kenmore Dryer Won Start or Run

Jan 14, 2016 | Dryers

1 Answer

Dryer quit won't start wife ran both washer/dryer same time put new breaker in still nothing?


Electric dryer no start does nothing

Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.

CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.

NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.

If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings

Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.

Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.

https://www.youtube.com/watch?v=sTRP6kHqAFs

Apr 18, 2015 | Maytag Centennial 7.0 Cu. Ft. Super...

1 Answer

I have an aeg lavatherm tn 95570 When I have started tumbledryer it will just go through the program without the motor running. The belt is ok and the only thing I can think of is, that the capasitor


Electric dryer no start does nothing

Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.

CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.

NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.

If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings

Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.

Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.

https://www.youtube.com/watch?v=sTRP6kHqAFs

Nov 20, 2014 | AEG Dryers

1 Answer

Ld505e power on board door switch ok no lights no start


Electric dryer no start does nothing

Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.

CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.

NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.

If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings

Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.

Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.

https://www.youtube.com/watch?v=sTRP6kHqAFs

Nov 09, 2014 | Dryers

1 Answer

I have as Kenmore 80 Series dryer. When we push start it does nothing


Hey GOD IS GOOD !!!!
Electric dryer no start does nothing

Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.

CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.

NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.

If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings

Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.

Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.

https://www.youtube.com/watch?v=sTRP6kHqAFs

Sep 29, 2014 | Dryers

1 Answer

Kenmore 970 c85092 00 dryer


Electric dryer no start does nothing

Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.

CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.

NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.

If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings

Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.

Lastly check ut push start button for continuity with a meter when pushed in the on position, it may have gone bad.


https://www.youtube.com/watch?v=sTRP6kHqAFs

Aug 19, 2014 | Kenmore Dryers

1 Answer

I have a Kenmore 80 Series dryer that just wouldn't start. The timer is getting power but motor doesn't seem to be trying to run. I wanted to take motor out to have it checked; I disconnected everything...


Electric dryer no start does nothing

Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.

CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.

NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.

If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings

Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.

Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.


https://www.youtube.com/watch?v=sTRP6kHqAFs

Jun 14, 2014 | Kenmore Dryers

1 Answer

Kenmore elite dryer wont start


Electric dryer no start does nothing

Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.

CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.

NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.

If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings

Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.

Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.

https://www.youtube.com/watch?v=sTRP6kHqAFs

May 27, 2014 | Kenmore Dryers

1 Answer

Kenmore dryer timer makes noise but wont run


Electric dryer no start does nothing

Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.

CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.

NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.

If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings

Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.

Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.

https://www.youtube.com/watch?v=sTRP6kHqAFs

May 15, 2014 | Kenmore 62882 Electric Dryer

1 Answer

Its plug in..when you push the button its never run


check the door pressure switch to see if its working. you can use a ohm meter for this test. you can also check by removing and inspecting the switch wires for lose fit. if the door pressure switch checks out ok, replace the start switch.

May 29, 2009 | Whirlpool Dryers

Not finding what you are looking for?
GE Profile Harmony DPGT750EC Electric Dryer Logo

Related Topics:

123 people viewed this question

Ask a Question

Usually answered in minutes!

Top GE Dryers Experts

Richard Roth
Richard Roth

Level 3 Expert

9472 Answers

John Tripp
John Tripp

Level 3 Expert

4636 Answers

gbob59

Level 3 Expert

2963 Answers

Are you a GE Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...