LG air conditioner model number LMN095HVT units keep on flashing with error code CH 46 and with no response at all. How can I fix it? Thanks for your help in advance!


ERROR CH46:
Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor.

Sep 01, 2015 | LG Heating & Cooling

1 Answer

CH-10 error code in LG a/c.Modal-LBUC609RSA5


RAC Product: Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C, 168 kOhm at 30C. Multi Fdx & Multi V text 8

Dec 24, 2014 | LG Heating & Cooling

1 Answer

Lg split system ch 46 error? help!!!


Ch-46Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor

Jan 07, 2011 | LG Art Cool LA181CNW Split System Air...

1 Answer

I have i lg cassette type ac model ltc46hle1 when power on showing display ch 2 ac not working


Ch-2 Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5
kOhm at 25C. If not replace sensor.

Helpful?

Jan 04, 2011 | Heating & Cooling

1 Answer

LG Inverter Air Conditioner showing CH 02 what can I do?


CH-02 Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5
kOhm at 25C. If not replace sensor

Dec 27, 2010 | Heating & Cooling

1 Answer

LG air conditioner 24awn error code message Ch 6 inside fan runs outside unit not working


CH-06 REFERS Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. if not replace sensor. THANKS.

Dec 13, 2010 | LG Art Cool LA121HNP Split System Air...

1 Answer

Nw my lg Aircon appear CH 46 how to solve this problem


Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor

Nov 18, 2010 | LG Art Cool LA181CNW Split System Air...

1 Answer

My LG tv wont tune all digital channels? im missing channel 7


Tv may need a firmware update or the Ch. is blocked in the Ch.menu.
Give LG a call @ 1 800 243-0000 they can give you more details.

Jan 19, 2010 | LG 50PS60 50 in. Plasma HDTV

1 Answer

LG Arena won't turn on after firmware update


I downloaded the LG Mobile Support Tool at http://www.51spsoft.com/Download.asp?ID=34522, which easily downloaded and installed the right firmware for me.

Aug 07, 2009 | LG KM900 Arena Cell Phone

Not finding what you are looking for?
LG Electronics CH10LS20 LightScribe 10x SATA Bluray Combo Internal Drive Retail Burner Logo

Related Topics:

30 people viewed this question

Ask a Question

Usually answered in minutes!

Top LG Computers & Internet Experts

Doctor PC
Doctor PC

Level 3 Expert

7733 Answers

Les Dickinson
Les Dickinson

Level 3 Expert

18392 Answers

Michael Vincent Cruz

Level 3 Expert

868 Answers

Are you a LG Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...