Open Question

I have error code f 75 on vaillant eco tec. have upped the water pressure and still code appearing, boiler wont lite

Posted by on

  • Anonymous Mar 15, 2009

    It appears to be a manufacturing defect! There are a lot of people, including me, with the same problem within the first two years. I intend to inform Which? and the Watchdog.



    The installer did warn me about problems with the switching valve/pressure sensor but I thought of economy and chose the Vaillant!!

×

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

If my vaillant eco tech combi boiler intermittently loses pressure does it mean I have a leak in the system somewhere


It could be have you bleed the rads of air . check the pressure relief valve it may be passing water .

Dec 07, 2016 | Heating & Cooling

1 Answer

I have a vaillant eco pro 28 combi boiler. no constant hot water unless tap is on really low.


Oh some of these there was a small black heatexchanger just for hot water they some times block up . or it could be a blockage in the water section where it flows in .I know Valliant have a very good tech line and fitters who do house calls .

Mar 02, 2017 | Water Heaters

1 Answer

Got a f.75 on boiler have to put pressure up to 2.0 bar before it starts


I take it this is a Vaillant EcoTec boiler? If your having to pressurise to 2.0 before the F75 goes, there's a strong probability there's a problem with the water pressure sensor. These can sometimes just have dirt/sludge in them, and can be cleaned, however a lot of the time they just need to be replaced. F75 can also mean there's a circulation problem through the boiler, and you will get the same fault code. If you have the old rubber hoses on the flow and return pipes, these can be prone to blocking/restricting and Vaillant have actually modified this part whereby by the pipes are solid copper.

Dec 04, 2012 | KDS Valiant 6380iPTD-01 Notebook

1 Answer

I have a vaillant eco tec pro boiler and the pressure guage is showing zero and boiler not working, is there a simple fis ?


Refill system with water to 1bar bleed rads refill again to 1 bar , there should be a filling loop to do this with.

Oct 23, 2012 | Grilling

1 Answer

Manual for a Vaillant combi boiler, ecoTEC pro28


my eco tec wall mounted boiler cuts out after about 10to15 days this unit was fitted in august this year

Sep 29, 2010 | Heating & Cooling

2 Answers

Hi my vaillant eco tec pro shut down last night showing fault f.28 and will not ignite today 08/01/2010 looked out side to see the condenser pipe was frozen i defrosted the pipe but boiler still wont...


Got exactly the same problem with mine. Manual says f28 = fault in gas supply, gas pressure too low. Boiler will ignite but goes out within minutes? HELP!

Jan 08, 2010 | KDS Valiant 6380iPTD-01 Notebook

6 Answers

Vaillant eco tec pro 28


IF the weather is extremely cold, and you're getting F28, the external pipework may be blocked with ice. Warm up the external pipes (lag them if you can) - and now see if your boiler will re-ignite.

A friend fixed our condenser boiler with this tip - hope it helps you.

Nov 14, 2008 | KDS Valiant 6380iPTD-01 Notebook

Not finding what you are looking for?
KDS Valiant 6380iPTD-01 Notebook Logo

Related Topics:

559 people viewed this question

Ask a Question

Usually answered in minutes!

Top KDS Computers & Internet Experts

yadayada
yadayada

Level 3 Expert

71183 Answers

Cleverer2

Level 2 Expert

298 Answers

Ed Mac

Level 3 Expert

731 Answers

Are you a KDS Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...