Question about Sony FD Trinitron WEGA KV-32FS120 32" TV

1 Answer

Video goes off led blinks 5 times then video returns, audio ok

Led keeps flashing after power switched off

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

  • Sony Master
  • 73,710 Answers

  1. Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly. For more details, check this.

Posted on Jan 09, 2013

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 1694 Answers

SOURCE: Bad picture color. red LED blinks 5 times. Replace picture tube?

Definitely bad picture tube==not worth fixing......T.

Posted on Oct 25, 2007

SOURCE: Doesn't turn on, but LED blinks 5 times

ws-65511 no power up
problem

Posted on Jul 20, 2008

daniel719
  • 240 Answers

SOURCE: Sony FD Trinitron WEGA KV-30XBR910 30" TV Led flashing

6 blinks meens no horizontal and no raster check capasitor c515/c516/ jungle IC and IC206.
regards,
daniel.

Posted on Jan 13, 2009

localwonder
  • 6784 Answers

SOURCE: TV cant be switch on, RED LED diagnostic Blinks .. 3 times... then 4 times. Please advise probable cause and send sTV hcematic diagram.

Hi, this is main board failure and you will need to replace this vital board. you power board is fine but, it is unable to send a proper current through the main mother board due to the damage at hand.

Posted on May 21, 2009

  • 1 Answer

SOURCE: Sony Wega KV-XF21M83 21" Color TV red LED flashing two times

mt sony trinitron power light is blinking from green to red twise and then pause for 3 seconds and then blinks again from green to red

Posted on Aug 14, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a Sharp Aquos 60" LED TV Model number LC-60LE65OU. No sound or picture. I am getting Error code 2 long flashes, 5 short flashes.


Those blinks [flashes] are fault indication (Error Codes). From the number of blinks occur at one time switch ON, you can get an idea about the faulty circuit section inside it. This will make repair easy. These are called blinking codes. Make sure about the exact number of blinking of the standby/power LED, by switching On & OFF the set, for at least two times. Count it carefully. If you wish to get some details, check the site linked here. It has details about blinking codes, and fault locating procedure, to many popular brand TVs and other devices.
http://electronicshelponline.blogspot.com/
If blinks continue without any pause, the main board is faulty.
Search the site by type in the "brand name" to your device, in the "Search box at the top right of the display window of the Homepage" to get gathered related posts.
Counting of number of blinks to Philips TVs is entirely different to that of other brand TVs. It is not a direct count procedure. The site have details about how to count the number of LED blinks [Fault Codes] to Philips brand TVs are given; along with details of the faulty circuit location.
Check whether the audio is muted by accidental press at remote control button. Enter its sound menu, and check it. If muted, as you know there will be no audio output. If not muted, Check the speaker/s. If found OK; check and replace the damaged component/s at its audio output section circuit board.

Dec 30, 2016 | Sharp Televison & Video

1 Answer

I have a sony rear projection TV model number kfws60s1 that will not turn on I press the on button and green light will flash 5 times then goes red again please help shed light into the problem pleaz


Understanding Sony Television Blinking Codes ' Techlore

www.techlore.com/article/understanding-sony-television-blinking-codes
Now the red light blinks 5 time while watching it. Is there any way of ..... 2006 that willnot power on and the green LED is blinking 6 times. We had a service ...

Sony KDF E55A20 - 5 Flashing Read Lights - TV Forums

www.tv-forums.com/.../TV.../TV.../Sony_KDF_E55A20_-_5_Flashing_...

Mar 17, 2012 - 14 posts - ‎4 authors
We have had a Sony KDF E55A20 since January 2006 and it has been trouble free. ...The TV will switch on fine green power lights. Then after about 20 ... If I turn off and turn on the power light will flash red 5 times. Leave it off ...

Sony TV - How to troubleshoot a red or blinking light ...

? 3:36
https://www.youtube.com/watch?v=BLkyFXv2-i4
Apr 6, 2012 - Uploaded by SonyListens
Sony TV - How to troubleshoot a red or blinking light ... and power lights, these easy steps will help you determine what the... 5:17. Easiest TV repair - How to Fix Power [TV turns off, freezes, ... Get video URL at current time.

Dec 02, 2015 | Sony Televison & Video

1 Answer

Samsung TV UN60EH6000FXZA 2 yrs old no video but audio and remote control are OK and LED flashes 6 times when powered up.


These blinks [flashes] are fault indication (Error Codes). From the number of blinks occur at one time switch ON, you can get an idea about the faulty circuit section inside it. This will make repair easy. These are called blinking codes. Make sure about the exact number of blinking of the standby/power LED, by switching On & OFF the set, for at least two times. Count it carefully. If you wish to get some details, check the site linked here. It has details about blinking codes, and fault locating procedure, to many popular brand TVs and other devices. http://electronicshelponline.blogspot.com/
Blinking codes details to many popular brand TVs are given. Surf the site with patience.

May 06, 2015 | Samsung Televison & Video

1 Answer

42lc46 zc


These blinks [flashes] are fault indication (Error Codes). From the number of blinks occur at one time switch ON, you can get an idea about the faulty circuit stage inside it. This will make repair easy. These are called blinking codes. Make sure about the exact number of blinking of the standby/power led, by switching On & OFF the set, for at least two times. Count it carefully. If you wish to get some details, check the site linked here. It has details about blinking codes, and fault locating, to many popular brand TVs and other devices. Viewing it in "Mosaic" will make surf easy.
http://electronicshelponline.blogspot.com/
Blinking codes details to many popular brand TVs are given. Surf the site with patience.

Mar 26, 2014 | LG Televison & Video

1 Answer

Sony tv kv ha21p52 the picture is shrinking in bottom few seconds the set goes to stand by the led bilinking four times plz help me


These blinks [flashes] are fault indication (Error Codes). From the number of blinks occur at one time switch ON, you can get an idea about the faulty circuit stage inside it. This will make repair easy. These are called blinking codes. Make sure about the exact number of blinking of the standby/power led, by switching On & OFF the set, for at least two times. Count it carefully. If you wish to get some details, check the site linked here. It has details about blinking codes, and fault locating, to many popular brand TVs and other devices. Viewing it in "Mosaic" will make surf easy.
http://electronicshelponline.blogspot.com/
Blinking codes details to many popular brand TVs are given.

Mar 23, 2014 | Televison & Video

2 Answers

I have a sony tv model kv-27v42 i have sound but no pictture and stand by light blinks what is the problem


How many times do this standby light blinks at a time of switch on? These blinks are fault indications. From the number of these blinks, you can get an idea about the faulty circuit section inside it. Count it. If you wish to get more details about the blinking codes to Sony TVs, check this link.

Feb 24, 2013 | Televison & Video

1 Answer

I was watching my kp61v80 and the screen went black-can you give me the trouble codes for the flashing standby light


Diagnosis item
TIMER/STANDBY
Indicater
Number of blinks
Supposed malfunction Condition
Self-diagnosis
screen display,
Diagnosis item: Results
•Power not ON 0
[Standby Power Supply System]
F601 open.
R607 open.
Q601 short circuit
[Main Power Supply System]
IC601 and R612 are broken.
VDR601 short-circuit
Cannot turn on the power.
LED doesn't blink.
+B OCP detection 2times Short circuit of power supply system in each circuit.
Goes to the standby mode
Short circuit of +B line
2 : +B OCP 000
+B OVP detection 3 times
T603 pin 78 open.
R672 open.
Goes to the standby mode
Malfunction of power supply circuit
3 : +B OVP 000
Vertical deflection stop 4 times
IC1509(V out) is broken.
Q1505(V Pulse Buffer) is broken.
Raster goes to one line horizontally, Aand then video
signal is muted.
4 : V Stop 000
Video out abnormality detection 5 times
Video out, Q705, 732, 761 and others in C board
circuit.
Q218, 219, 220 (A board)
TIMER/STANDBY LED blinks approx. 30 seconds,
and then blinks for the self diagnosis.
5 : AKB 000
Horizontal deflection stop 6 times
C515, 516 open.
IC206(YC Jungle) is broken.
Raster doesn't appear. 6 : H Stop 000
Audio abnormality detection 8 times
IC406(Audio amp.) is broken.
PS401, 402 open.
The sound is not out.
Goes to the standby mode
8 : Audio 000

Jun 17, 2009 | Televison & Video

1 Answer

Mitsubishi 52144 won't power on with blue flashing led


Those blinks [flashes] are fault indication (Error Codes). From the number of blinks occur at one time switch ON, you can get an idea about the faulty circuit section inside it. This will make repair easy. These are called blinking codes. Make sure about the exact number of blinking of the standby/power LED, by switching On & OFF the set, for at least two times. Count it carefully. If you wish to get some details, check the site linked here. It has details about blinking codes, and fault locating procedure, to many popular brand TVs and other devices.
http://homenol.blogspot.com/
http://electronicshelponline.blogspot.com/
If blinks continue without any pause, the main board is faulty.
Search the site by type in the "brand name" to your device, in the "Search box at the top right of the display window of the Homepage" to get gathered related posts.

Mar 12, 2017 | Mitsubishi LT-52144 52 in. LCD HDTV

1 Answer

Getting out of standby mode


That blinks and flashing have a diagnostic code;

Here is a list of the problems that might have occurred indicated by the number of blinks. The words in parentheses are those, which you will see for each of these faults on a diagnosis screen described later in this article.
  • Unit is dead, No blinks - Problem in the standby power section. Might check fuse, R607, Q601, IC601, R612 and VDR601 (should show open).
  • Continuous blink once a second, no pausing - No reply from the jungle IC301 (data bus is busy, shorted to ground, or held high), IK video path is defective.
  • One blink - not used for the self-diagnosis
  • Two blinks - B+ over current protection (OCP), unit goes to the standby mode then displays the 2 blink fault. Could be a short in the power supply of any of the circuits.
  • Three blinks - B+ over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672.
  • Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted. Check IC1509, Q1505
  • Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.
  • Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 & 516 and the jungle IC, IC206.
  • Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits.
  • Eight blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board.
  • Nine blinks - Replace D 6116 and D 6301 on the "G" board, do not resolder as this will fix the problem temporary. Or Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times you get flashing, then change the switching regulator on the "G" board or check connections. Make sure the regulator is -12 or -13 (negitive).
  • Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the " D" board. If the transistors are bad, check R8051 and IC8005, also on the "D" board.
Intermittent problems? This is a great feature. You can also bring up these fault codes on-screen to see a list of the problem numbers with the abbreviation of the problem and the number of times this problem has occurred. This is slightly different than entering the service mode. To see the diagnostic screen, press the following buttons: Display, Channel, 5, volume Minus, ( not plus ) then Power. This brings up a screen with a list of the problems and number of times they have occurred. Each of the problems named, are abbreviated as, "OCP", "OVP", "V STOP", ETC. We have repeated them in parentheses in the text for the "Blinks" described above so you can correlate between the diagnostic screen and the blink codes.
Now that you know about these self-diagnostics, how do you use them? Say that you have a set with a black screen. You see that the LED is blinking four times. This would tell you that you have no vertical sweep, which is why the video is muted. If it was blinking 6 times, you would know that you have a horizontal fault. It's not a sure cure..
IMPORTANT: After you repair the unit, you MUST clear the values on this diagnostic screen. These codes do not reset themselves after the fault is corrected, so if you don't clear them, you'll be seeing "old" fault codes the next time you enter this screen. Clearing is done by going into the service mode (display, channel, 5, volume plus, then power ). Press 8 and Enter, which returns everything to the factory preset condition.

Hope it may help you;

Regards,
VOTIT

Aug 19, 2008 | Sony FD Trinitron WEGA KV-36HS500 36" TV

1 Answer

My 61 In sony xbr flashes the standby light 5 times


Many of the later model Sony TV’s have a built in self-diagnosis function. If the timer/standby indicator is blinking, this could be an indication of a problem with the unit. The diagnostic blinking will occur automatically with no action required by you to engage it.
The timing of the blinking you see would be as follows: two to nine blinks, (depending on the fault), about a third of a second apart, then a pause for 3 seconds, then the two to nine blinks about a third of a second apart again.
Here is a list of the problems that might have occurred indicated by the number of blinks. The words in parentheses are those, which you will see for each of these faults on a diagnosis screen described later in this article.
  • Unit is dead, No blinks - Problem in the standby power section. Might check fuse, R607, Q601, IC601, R612 and VDR601 (should show open).
  • Continuous blink once a second, no pausing - No reply from the jungle IC301 (data bus is busy, shorted to ground, or held high), IK video path is defective.
  • One blink - not used for the self-diagnosis
  • Two blinks - B+ over current protection (OCP), unit goes to the standby mode then displays the 2 blink fault. Could be a short in the power supply of any of the circuits.
  • Three blinks - B+ over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672.
  • Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted. Check IC1509, Q1505
  • Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.
  • Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 & 516 and the jungle IC, IC206.
  • Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits.
  • Eight GA_googleFillSlot("TL-IMU-Article");blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board.

  • Nine blinks - Replace D 6116 and D 6301 on the "G" board, do not resolder as this will fix the problem temporary. Or Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times you get flashing, then change the switching regulator on the "G" board or check connections. Make sure the regulator is -12 or -13 (negitive).
  • Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the " D" board. If the transistors are bad, check R8051 and IC8005, also on the "D" board.

Mar 28, 2008 | Sony KP-61XBR48 61" Rear Projection...

Not finding what you are looking for?
Sony FD Trinitron WEGA KV-32FS120 32" TV Logo

99 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sony Televison & Video Experts

kakima

Level 3 Expert

102366 Answers

The Knight
The Knight

Level 3 Expert

73698 Answers

Jerry Greenberg
Jerry Greenberg

Level 3 Expert

1667 Answers

Are you a Sony Televison and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides