I noticed a burning smell from the kitchen, and the advantium oven panel was dark. I opened the door and it was EXTREMELY hot. The glass plate was too hot to touch. I unplugged it and let it sit for awhile, and plugged it back in. When you turn on the microwave, it makes a loud clicking noise like the speedcook is on, and it gets very hot. Tried turning on the speedcook, and there was smoke.. It's a 2005 Advantium 120

Posted by on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
MicrowaveSvc
  • 9047 Answers

SOURCE: Advantium 120 door handle breakage

You can usually find helpful exploded view diagrams and order parts by entering your full model number here.

Normally you have to separate the door panels (as shown in the attached photo) and then you'll see the previously hidden screws you need to remove.

Or you can watch a YouTube video (not a video I made) here that demonstrates how it's done.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

7eca6a7.jpg

Posted on Aug 03, 2008

Ad
  • 1 Answer

SOURCE: cleaning advantium microwave

How do I clean the interior walls of the microwave over. Also any ideas about cleaning the glass on an oven.

Posted on Nov 28, 2008

MicrowaveSvc
  • 9047 Answers

SOURCE: GE Advantium 120 Microwave fan stays on, off only when door open

Looking at the schematic in the service manual here, I would say relay RY6 on the small sub PCB (relay board) has shorted contacts.

That's the relay that runs both the fan and turntable.

It's possible that it may be a bad connection or driving component on that board, but in my experience, it's virtually always a stuck relay.

The part number on the relay as shown in the photo is hard to read, but it looks like "OJ-SH-112LM".

I should have one of these or I can point you to one if you want to contact me with the exact number.

Feel free to contact me directly (and please remind me of your full model number) for more information & help.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

William E. Miller
prototech@usa.net
http://www.microwavedisplay.com

7e1615b.jpg

Posted on Jan 31, 2009

  • 10865 Answers

SOURCE: The door handle on my GE Profile ADvantium 120 Microwave is broke

You may consider using epoxy to "glue" the handle back into place. The epoxy will be stronger than the handle itself. If you do this get the one minute epoxy

Posted on Apr 27, 2009

dmftrucker
  • 1922 Answers

SOURCE: replace fuse on GE Advantium Speedcooker Oven

there is a fuse located underneath the outer cover, its called a ceramic fuse and is of cartridge type about 1" long by 1/8" diameter and has a white body and 2 silver ends and you can take it to a hardware store they have them but make sure to get correct amperage rating 15 or 20 amp

Posted on Sep 26, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Advantium 120 interior light won't go out


door switch is bad or out of adjustment I have a dometic that does this sometimes I just slam it a little harder

Jan 29, 2014 | GE Advantium 120 Convection/Microwave Oven

1 Answer

Won't shut off


You may have a problem with a door switch or door switch mount, or there may be a shorted relay on the control board, which can easily be repaired.
Our help file on door switches is here, and the Advantium 120 service manual is here.
You can order GE parts from the Pros here.

Jun 06, 2013 | GE Advantium 120 Convection/Microwave Oven

1 Answer

How to change nightlight bulb on ge advantium 120 oven


Advantium - Interior Light Operation While Microwaving

The Advantium 240 oven interior (cavity) light will illuminate anytime the door is open. However, due to the dark tint on the oven door, there is not a light on while cooking since the food would not be visible using the interior lamp.
Food may be viewed during a microwave cycle by pressing the Microwave/Oven Light pad.

One of the Upper Level Speedcook lamps will come on for 5 seconds. The Microwave/Oven Light pad can be pressed up to 5 times during a microwave cooking cycle. The limit of 5 times is to prevent excessive heat on microwave cookware from the Speedcook lamp.

The Advantium 120 oven cavity is illuminated anytime the door is opened and while the unit is in the microwave only mode. As a result it will not have the Microwave/Oven Light pad.

Aug 25, 2012 | GE Microwave Ovens

1 Answer

GE Profile Advantium 120 oven: Clock is on and stuck, unit will not work otherwise.


Unplug the microwave oven for 60 seconds to reset microprocessor, hopefully this will cure the problem.

Jul 05, 2012 | GE Profile Advantium 120 Wall Oven

2 Answers

Interior bulb needs to be replaced. What needs to be removed to gain access? Thanks


Advantium - Interior Light Operation While Microwaving

The Advantium 240 oven interior (cavity) light will illuminate anytime the door is open. However, due to the dark tint on the oven door, there is not a light on while cooking since the food would not be visible using the interior lamp.
Food may be viewed during a microwave cycle by pressing the Microwave/Oven Light pad.

One of the Upper Level Speedcook lamps will come on for 5 seconds. The Microwave/Oven Light pad can be pressed up to 5 times during a microwave cooking cycle. The limit of 5 times is to prevent excessive heat on microwave cookware from the Speedcook lamp.

The Advantium 120 oven cavity is illuminated anytime the door is opened and while the unit is in the microwave only mode. As a result it will not have the Microwave/Oven Light pad.

If the light is not operating properly, you will want to have it checked by an authorized service technician. To obtain in or out of warranty repair on Major Appliances, you may call 1-800-GE-CARES (800-432-2737) or schedule service online.
Advantium - Interior Light Operation While Microwaving

The Advantium 240 oven interior (cavity) light will illuminate anytime the door is open. However, due to the dark tint on the oven door, there is not a light on while cooking since the food would not be visible using the interior lamp.
Food may be viewed during a microwave cycle by pressing the Microwave/Oven Light pad.

One of the Upper Level Speedcook lamps will come on for 5 seconds. The Microwave/Oven Light pad can be pressed up to 5 times during a microwave cooking cycle. The limit of 5 times is to prevent excessive heat on microwave cookware from the Speedcook lamp.

The Advantium 120 oven cavity is illuminated anytime the door is opened and while the unit is in the microwave only mode. As a result it will not have the Microwave/Oven Light pad.

If the light is not operating properly, you will want to have it checked by an authorized service technician. To obtain in or out of warranty repair on Major Appliances, you may call 1-800-GE-CARES (800-432-2737) or schedule service online.
Advantium - Interior Light Operation While Microwaving

The Advantium 240 oven interior (cavity) light will illuminate anytime the door is open. However, due to the dark tint on the oven door, there is not a light on while cooking since the food would not be visible using the interior lamp.
Food may be viewed during a microwave cycle by pressing the Microwave/Oven Light pad.

One of the Upper Level Speedcook lamps will come on for 5 seconds. The Microwave/Oven Light pad can be pressed up to 5 times during a microwave cooking cycle. The limit of 5 times is to prevent excessive heat on microwave cookware from the Speedcook lamp.

The Advantium 120 oven cavity is illuminated anytime the door is opened and while the unit is in the microwave only mode. As a result it will not have the Microwave/Oven Light pad.

If the light is not operating properly, you will want to have it checked by an authorized service technician. To obtain in or out of warranty repair on Major Appliances, you may call 1-800-GE-CARES (800-432-2737) or schedule service online.
Check here

http://www.geappliances.com/search/fast/infobase/10000007.htm

Advantium - Interior Light Operation While Microwaving

The Advantium 240 oven interior (cavity) light will illuminate anytime the door is open. However, due to the dark tint on the oven door, there is not a light on while cooking since the food would not be visible using the interior lamp.
Food may be viewed during a microwave cycle by pressing the Microwave/Oven Light pad.

One of the Upper Level Speedcook lamps will come on for 5 seconds. The Microwave/Oven Light pad can be pressed up to 5 times during a microwave cooking cycle. The limit of 5 times is to prevent excessive heat on microwave cookware from the Speedcook lamp.

The Advantium 120 oven cavity is illuminated anytime the door is opened and while the unit is in the microwave only mode. As a result it will not have the Microwave/Oven Light pad.

If the light is not operating properly, you will want to have it checked by an authorized service technician. To obtain in or out of warranty repair on Major Appliances, you may call 1-800-GE-CARES (800-432-2737) or schedule service online.

Aug 25, 2010 | GE Advantium 120 Convection/Microwave Oven

1 Answer

GE Advantium Microwave section doesn't work.


The primary interlock switch on my Advantium has failed twice. The replacement part is available at: appliancepartspros.com part no. for my Advantium was AP2622452 and it cost $11.74 + $6.95 shipping.

For what it's worth, my nylon connector and wire covering were also scorched a bit but the last primary interlock switch lasted me for over a year.

Please note that I am not an expert at repairing appliances and that I assume no responsibility or liability for any attempt you may make to repair your own appliance.

May 30, 2009 | GE Advantium SCA2000B Microwave Oven

1 Answer

Control panel "locked" on ge advantium 120


You might have set the child lock. Look in the manual. It is on P.36 in my manual.

Apr 30, 2009 | GE Advantium 120 Convection/Microwave Oven

1 Answer

Advantium 120 problem


dis connect from power alow to reset for about a minute . if not there are switches behind the door probably not making good contact make sure door is closed tightly

Jul 30, 2007 | GE Advantium 120 Convection/Microwave Oven

Not finding what you are looking for?
GE Advantium SCA1001SS Convection / Microwave Oven Logo

Related Topics:

31 people viewed this question

Ask a Question

Usually answered in minutes!

Top GE Microwave Ovens Experts

William Miller
William Miller

Level 3 Expert

9047 Answers

Devabhakthuni...
Devabhakthuni...

Level 2 Expert

225 Answers

Shekar Avadhani

Level 2 Expert

61 Answers

Are you a GE Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...