Kohler shower facuet pressure balancing problem?

We have a shower faucet made by Kohler, T15101-4S. One day the water stopped coming out. After replacing the pressure regulator (2 cartridge shape) and the stem adapter, it became erratically. Sometimes water came out even though the handle is turned to off. Sometimes water wouldn't come out. Sometimes the water couldn't be shut off so we had to shut off the main water. I called Kohler. They said it's a water-balancing problem between hot and colder water. How could I fix it? It's also worrisome to see the faucet doesn't have anything to shut off the water mechanically. The water can come out when nobody is at home. Thanks!

Posted by on

  • angelent1 Jan 23, 2009

    It doesn't look difficult to align the parts. The pressure regulator only goes in one-way and it doesn't move. The stem adapter lines up with the pressure regulator easily. Only the inside of the stem adapter rotates with the handle.

    I was wrong saying that the faucet doesn't have anything to shut off the water mechanically. The stem adapter has two openings that are pressed against a plate to shut off the water. The problem is it doesn't work sometimes. The faucet seems work a few minutes then the water would come up while the faucet is shut off. It's crazy.

×

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 547 Answers

It sound to me like bad pressure I think you need to add a pump to your main .

Posted on Feb 17, 2009

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 49 Answers

Ever since the pressure balancing regulations came out for shower valves, they have went from simple to very complicated devices. sounds as if some foreign material caused the valve to stop working. that valve is quit difficult to reassemble correctly because there is only one way it works and can be assemmbled many ways that do not work concerning alignment of the ports. if you dissassemble it and check that all the moving parts are functioning in the balancing cartridge you can then look closely at the alignment of the ports on the cartridge that the handle is connected to. understanding how the port align as the handle is turned should assist you in assembling it correctly......hope this helps.

Posted on Jan 23, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

No hot water in shower. Sometimes runs hot then goes cold or runs cold. I have less than 2 year old Kohler Faucet K-T10448-4-CP. I replaced the pressure balance valve unit. No luck. I changed the hot...


Refer to the manufacturer's recommendations for back-flushing/descaling to flush out mineral deposits and build-up in the heat exchanger. You can check to see if this is a problem by comparing the full cold water flow with full hot water flow at the faucet. If the hot water flow is significantly slower than the cold then the heat exchanger is likely clogged with deposits and will not transfer heat sufficiently. If the flow is good then the heating element(s) maybe defective.

Feb 17, 2015 | Kohler Faucets

1 Answer

The shower does not get hot so i took pressure balance unit apart and cleaned also took hot limit stop off .still not hot rest of sinks in house are hot and furnace right under shower,what do you think it...


When shower faucet apart make sure hot is getting 2 & coming out faucet ***. did you turn off stop integral w/ faucet or outgoing shut off valve on water heater.. May have rust or lime in small orifice leading to faucet ***. does your balancer/ piston move freely..good luck..

Mar 24, 2011 | American Standard Bath Faucet Ceramix...

1 Answer

My water heater was serviced(drained and circ pump replaced) and I'm still getting lukewarm water for my showers. It doesn't get as hot as it used to at all. I can't even wash my hair-it gets cold too...


If the water is only cool in the shower, it could be the shower valve. However if water is cool at all taps, something is not working on the water heater system.
Gary

Dec 18, 2010 | Kohler K-T10335-4-CP Lyntier Rite-temp...

1 Answer

My heater stops working in the middle of the night. I have to get up to re set it but it turns off by the time i get back to bed. By 10 AM it starts working again on its own. its done this for 2 years and...


the Model number you gave is for a Shower Head what do you mean it doesnt heat... it only conrtols the water temp by BALANCING the hot and cold water inlets does NOT heat anything if your water is cold then check another PLAIN faucet to see if your water is the same temp( cold) if it is the hot water from water HEATER is cold nothing to do with faucets

Nov 22, 2009 | Kohler K-T462-X4V-CP Memoirs Rite-Temp...

1 Answer

No hot water pressure on kohler bath / shower faucet


Try draining the system and apply air pressure (min 30psi) to each faucet. Open other hot water faucets to allow pressure to vent. Next try draining and cleaning the hot water tank.

Oct 07, 2009 | Kohler K-T10335-4-CP Lyntier Rite-temp...

1 Answer

Faucet issue


Sounds like it was installed upside down or the cartridge is installed improperly

May 06, 2009 | Kohler K-T10335-4-CP Lyntier Rite-temp...

2 Answers

Just installed shower and faucet in bath tub when you turn the water on the water comes out of the faucet and shower head. When you pull the lever for just the shower the water cuts off at faucet and comes...


Verify the height from the shower valve to the Shower head, the instructions specify the correct distance if it is too short the pressure could be getting up to the shower head.

Perhaps the water pressure it too high at the valve not allowing all the water down the faucet outlet, there are set screws on the sides of the shower valve to adjust the water allowed in the mixing chamber.

Something is restricting the water flow to the faucet, creating enough pressure to send some of the ater supply up to the shower.

I hope some of these ideas help

Mar 01, 2009 | Faucets

1 Answer

Pressure problem with Kohler shower faucet??


Hi pglaw,

My best guess is the supply valve for the hot side isn't open all the way. This valve is right on the valve and is accessed by taking off the front cover plate. This would still allow the pressure balancing valve to let water through but then you would have a small flow on the hot side.

If this isn't it then then cartridge is bad.

Please rate this response and good Luck,, phil

Dec 30, 2008 | Kohler K-T10335-4-CP Lyntier Rite-temp...

1 Answer

No water coming out of my Kohler Forte R10275-4-BN shower valve


This is a pressure balancing valve that needs both cold and hot water pressure to operated. It is an anti-scald safety operation.

Good Luck, Phil

Dec 25, 2008 | Faucets

Not finding what you are looking for?
Kohler K-T10335-4-CP Lyntier Rite-temp bath and shower faucet with lever .... Logo

1,294 people viewed this question

Ask a Question

Usually answered in minutes!

Top Kohler Faucets Experts

Mike

Level 3 Expert

4331 Answers

Michael R. Turner

Level 1 Expert

18 Answers

80stech

Level 2 Expert

92 Answers

Are you a Kohler Faucet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...