1 Answer

Engine runs but won't generate any electricity

Coleman Powermate 7500 watt 12 H.P. generator mod.# pm0116000.
This generator has very low hours, the engine runs perfectly but the generator will not produce any electrical power from the outlets.
It ran fine a couple of times, it's alomost brand new and there was no incidents where I can say a problem would of occured.

Please help.

Ben

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 204 Answers

Sometimes the generator loses the magnetic field that allows it to produce power. Do a Google search on "flashing a generator field". There are many ways to do it, but I would recommend doing some reading before trying it. Your "dead" generator could produce hazardous voltage once it comes back to life.

Also, before trying any of this, make sure the circuit breakers on the generator (if equipped) are not tripped.

Good luck and be careful!

Posted on Jun 16, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a coleman powermate 6250 generator it get gas and spark and oil is fine but wont start


Lets see, Do you have any ether or old school lighter fluid? If you use ether spray a little into the air intake just before you pull the cord for a start, if it starts you have a carb problem. Same for the lighter fluid, remove the spark plug and squirt a small amount down in the cylinder, again if it starts you have a carb, probelm. Take the carb. off the engine take note of the rods and springs, take a picture get it in good focus so you can put it back together. Take the fuel bowl off the bottom of the carb and clean the jets and all see if that will help.

Feb 27, 2010 | Coleman 10' X 10' Sundome Tent 9160K101

2 Answers

Need manual for coleman powermate 1850 generator


google it! use the specific search terms, Coleman power pulse 1850 - it worked for me!

Jun 05, 2009 | Coleman 10' X 10' Sundome Tent 9160K101

1 Answer

My Coleman Powermate Pulse 1750 generator shuts down


Your generator should run a power tool rated at 10 amps. The 15 amps you mentioned for the PM1750 is for the DC rating. The AC rating is 11.6 amps.

May 28, 2009 | Coleman 10' X 10' Sundome Tent 9160K101

2 Answers

Coleman Powermate 8750 will not generate electricity.


I had a similar situation with a friends generator. After sitting around unused for a few years it would not generate because the residual magnitism was weak. I plugged a light into it and by using the throttle arm I breifly ran up the RPM and the light came on. DO NOT MAINTAIN THE HIGH RPM FOR MORE THAN A FEW SECONDS.

Feb 25, 2009 | Coleman 10' X 10' Sundome Tent 9160K101

2 Answers

In need of manual for a coleman PM0435003 Powermate Generator...


try Play it again sports

they have a large network of used sports gear and network of stores that get all inds of used stuff
They are individually owned so be persistent

Dec 20, 2008 | Coleman 10' X 10' Sundome Tent 9160K101

1 Answer

Oil leaking from generator


Whose engine do you have? Briggs and Honda have websites where you can down load their manuals and replace the rear seal.

Dec 15, 2008 | Coleman 10' X 10' Sundome Tent 9160K101

Not finding what you are looking for?
Coleman 10' X 10' Sundome Tent 9160K101 Logo

487 people viewed this question

Ask a Question

Usually answered in minutes!

Top Coleman Sport & Outdoor Experts

David Payne
David Payne

Level 3 Expert

13437 Answers

tb55chevy

Level 1 Expert

7 Answers

kakima

Level 3 Expert

96372 Answers

Are you a Coleman Sport and Outdoor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...