I need the wiring for my PGB 060150 blower has a blk/wht/purple and stove does not the motor is a 2 speed 220 fan

Posted by on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 143 Answers

SOURCE: CHANGING OUT A FAN MOTOR

The black and white wires get 220 from the contactor. The brown and brown/white go to the capacitor. I do hope you bought a matching capacitor to go with the new motor. They don't cost much and make the hook-up way easier.

Posted on Jul 25, 2008

Ad
  • 2 Answers

SOURCE: Goodman Air unit - Blower Fan will not kick on

same problem....any solutions yet?

Posted on Nov 12, 2008

farfield
  • 462 Answers

SOURCE: RV AC, how to wire fan (blower) motor to capacitor.

You almost have it Look closer at the run capacitor. It has Herm, this is for the compressor, Com or C and F or Fan.

1 of your power wires is the fan speed so connect them accordingly usually black is hi, blue med, & red is low. You are "feeding" voltage to the selector switch on 1 side and coming out to the fan motor speeds.

Next you have a "Common" wire on your fan motor (this means its Common to all the other connections inside the fan motor to me. It is usually white. Connect this to the other line of power usually the Com on the capacitor unless it connects to a strip on the selector switch. But 1 of these 2 places will be the other side of your Power when plugged in. Lastly the brown it is usually the fan capicator only wire and it will connect to the fan "F" terminal on the capicator this terminal will not have any other wires connected to it.

This should make you a happy camper. Please rate me accordingly and good luck.

Posted on Mar 08, 2009

bobicehouse
  • 1524 Answers

SOURCE: i need to change blower motor

See if you can move it freely by hand. If so, change the fan capacitor. If tight, try oiling the motor.

Posted on May 01, 2009

  • 587 Answers

SOURCE: replacement fan motor for coleman mach3..need wiring diagrm

COLEMAN R.V. AIR CONDITIONER SERVICE AND REPAIR QUESTIONS
COLEMAN R.V. PRODUCTS
GO TO rvcomfort.com

Click on RVP (RV PRODUCTS)
Click on type of AC, if you can’t find the information you want there,
then click on contact us on the Green Bar.
You can get Service Support or Email address and Phone numbers.

Posted on Jun 16, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Goodman AC blower is not working. How do I fix this problem?


You need a simple relay. But, if you want it to run and never stop temporarily, take the black wire off the relay on the board ( the wire that goes back to the 240 side of the transformer and run it straight to the speed tap from the motor that's connected to the relay. I'll help you with the relay when you get when but this will make it run provided the board or relay is bad.

May 27, 2017 | Goodman Heating & Cooling

1 Answer

Blower motor installation


just check the wiring diagram and connect the two wires for the desired speed and put a wire nut one the third one.

Aug 08, 2014 | Emerson NEW A/C Fan MOTOR 1/4 1/6 1/8 HP,...

1 Answer

Mars blower motor diagram?4 wires


Gentlemen,
I have a GE P547BS fan motor. I find replace it with a Mars 10584 fan motor. GE has five wires, BRN, YEL,PUR,BLK,RED. Goes through the capacitor with the yellow going on to 200 V the purple and black go to 220 V. Mars motor as a six wire connection two Brown's go to the capacitor. yellow I'm assuming goes to the hot/neutral and a black I would say would be high-speed blue is medium and red is low. Now when I connect with this way it blows the fuse. Anybody run into this problem before? Any help? By the way, it's a 240 V single phase system.

Jun 05, 2012 | Heating & Cooling

1 Answer

High voltage blower motor wiring diagram for air handler model ar36-1


you should have three wires if its factory specified and it should be purple,brown,black purple goes to common on capacitor,brown to fan on cap and blk to defrost board

Sep 14, 2010 | Heating & Cooling

1 Answer

How do a replace the blower motor resistor on a 2002 pontiac sunfire?


Should be on Driver Side under dash, will have 4 wires colored : BLK/WHT, TAN, LT BLU & ORG ! The Resistance is connected to the harness that control the Fan Speed on the Heater Control Panel !

Aug 11, 2010 | 2002 Pontiac Sunfire

2 Answers

Replaced old Ge 1/2hp fan blower motor w/ emerson motor wire not the same couldnot get to work. motors has blk,blue,red,white/brown, brownw/white strip/furance wires are blk,red,white could some tell me...


I am assuming you still have both motors, if you look on the side they will show you what wires go to what. Your Brown/white should be for the capicator. blk should be blk, blu might be white and red be red. I couldn't really say for certain with out looking at the diagram on the side of the motors. I hope this helped Tim

Aug 02, 2010 | Heating & Cooling

1 Answer

My blower fan came off the motor shaft.


THE BLOWER MOTOR HAS 6-WIRES ....2--CAPICATOR (BROWN- BROWN WHITE STRIPE)3- SPEEDS BLACK-HI-SPEED--BLUE--MED......RED--LOW SPEED OR HEAT AND THE LAST ONE TO COMMOM.

Nov 23, 2008 | Goodman GMS90703BXA Heater

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

39 people viewed this question

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Paul Carew

Level 3 Expert

2597 Answers

Tim Whalen

Level 3 Expert

3074 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...