How to change thermal coupler on ge gg28t06axk gas water heater step by step

Pilot wont stay lit after breaker was tripped

Posted by Anonymous on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
  • 2 Answers

SOURCE: Rheem 40 gallon gas hot water heater, pilot light

To make a short story long (I need to include all details, sry)…

I got up one morning and realized that we did not have hot water. I re-lit the pilot light and as soon as the burner went out from heating the water up, the pilot light would go out. After reading several posts regarding this issue, it seemed apparent that the thermo-coupler was the problem. Since I am a little bit handy around the house and very tight when it comes to opening my wallet, I bought the device from Lowe’s ($8.98) that was recommended by my online advisors and after a few googles, figured out how to change it. No help. The pilot light still goes out.

I gave up and went to Home Depot to purchase and schedule the installation of a new hot water heater.

STICKER SHOCK

A new Direct Vent type water heater costs around $800 with an additional $450 for “special” installation. Add a few fees to that and the grand total came to about $1450.

I felt like I had no choice since my wife and 2 daughters refused to live their life without hot water and I had no clue about how to fix the dam thing.

The plumber assigned to the installation stopped by to evaluate the site conditions and quickly noted to me that the 8 year old water heater tank was in good condition and that the gas controller was probably faulty, which could be purchased online from the manufacturer. I quickly cancelled the Home Depot order and purchased the controller for about $120 after shipping and tax. Immediately after the installation it seemed that the problem had been solved. A few days later the pilot light went out.

I called the plumber and explained the situation and he recommended that I purchase another controller because the one that was shipped to me was probably bad. I searched around town and found a plumbing supply company that had the correct model in stock. Two days later the pilot light was out. I cleaned up the controller and returned it to the store and asked the plumber to please schedule a visit to repair this dam thing.

When the plumber arrived, he hooked up a gauge in several locations and confirmed that the correct amount of gas (cfm) was being delivered to the controller, pilot light and burner. He then proceeded to remove the fire box to make sure that the igniter, thermo-coupler and pilot tip were set properly. He inspected the pilot light tip and said that he found the problem. Using about a 1/64” tip drill (can be purchased at a welding supply store), he cleaned the tiny hole that releases gas to the pilot light. I felt a sigh of relief because I was certain that the problem had been solved. $65 dollars (plumber’s fee for an hour of work) and 4 days later the pilot light went out.

I called the plumber and he said that the controller that I purchased online must be bad. Too embarrassed to return to the first plumbing supply store, I found another one in a different town that had the correct model in stock. Three days after changing the controller the pilot light went out. I returned the controller and a six pack later I decided to do some extensive googling.

The key term here is “DIRECT VENT”. This seems to be a very common problem with direct vent water heaters and I was about to find out the reason for this phenomenon. I read a post by an individual who wrote that if the vent becomes detached that the inflow of air can become contaminated and extinguish the pilot light. I decided that before I spent any more money on a plumber that I was going to take the vent apart and find out what makes it tick.

My direct vent system has 2 parts to the venting, an inner pipe (3” nominal diameter) that serves as the exhaust and the outer pipe (5” nominal diameter) that serves as the internal flow of air which supplies the pilot light and burner with oxygen. On the outside of the house a vent hood helps to segregate the two by extending the exhaust about 3” beyond the intake. I looked into the hood at the end of the pipes and discovered that the internal pipe which consisted of a 2 piece slip joint had come loose from the elbow that sets on top of the water heater. This slip joint pipe was not attached at any point with screws or clamps and was loosely setting over the elbow on one end and into the hood on the other end, allowing it to detach. Apparently, when atmospheric conditions were right, the burner idled down from heating up the water and extinguished the pilot light because the intake was saturated with CO2 from the connection failure.

I purchased a section of 3” pipe that was long enough to be installed in one piece. I connected it to the elbow using a stainless steel hose clamp. I had to disassemble the pipe 3 times to make adjustments to the length and position before I got it right, but I should not have any more problems with the pilot light.

The problem here is time. It takes a lot of time to get this right. When the plumbing contractors installed this unit during the construction of the house, there was no one around to make sure that they got it right. It is probably common to use a 2 piece slip joint type connection, but I feel like it should be attached with screws or clamps. In my opinion it is not rigid enough and can detach easily, especially if it is not installed properly. A one piece connection that is attached at one end with a hose clamp and then held in place at the other end by the hood is fool proof.

Posted on Sep 27, 2009

Ad
canddplumb
  • 35 Answers

SOURCE: GE Smartwater Heater model# GG40T6A won't stay lit

Look and see if your pilots flame is touching the themocoupling ,if it isnt then cleane your pilot orfice.If that dosnt work replace thethermocoupler.I would also check the draw. Hold alit match or a cigerett up to the draft diverter (the air space between your heater and the vent. If it dosent draw the smoke up the vent it meanes your vent is stoped up or you need to raise it.

Posted on Dec 02, 2009

kel1guy2002
  • 3740 Answers

SOURCE: pilot light on water heater wont stay lit

The thermocouple has failed. It is the temp probe that goes from the pilot lite burner area to the control valve. Go to your local plumbng repair shop and buy one. Most appliance parts stores have them also. Take the old one with you and they will hook you up with an exact replacement. They are not that hard to change. Usually a nut or 2 screws in the temp bulb area at the burner end and a nut that threads into the control valve.
Make sure before you install the new one that the area where it mates to the gas valve is clean. Should be about a 20 min job including clean up with replacement parts in hand.

Posted on Jan 23, 2010

Testimonial: "exactly what I wanted yo know. thank you"

  • 1 Answer

SOURCE: i have a richmond gas hot water heater model

lock out code....turn off unit for 1 minute (unplug) press both arrows and hold for 5-10 sec... then enter L R L L ... R L R R...that should reset it.

Posted on Jul 25, 2010

  • 1 Answer

SOURCE: Pilot won't stay lit in Reliance 606 gas water heater

The Reliance 606 has an enclosed thermal couple. Before you try taking that assembly apart take a wire brush to the bottom opening directly under the burner. There is a metal filter on the very bottom of the water heater. It could be that the filter has gotten filled with dust or animal hair. It took a serviceman 2 days to figure this out for me. The water heater has to have good airflow through that filter to work well.

Posted on Sep 29, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I light pI lot and it stays lit burners light and reach temp but then burners wont relight to keep temp unless I tap gas valve..is it my gas valve


A lot of pilot lights have a thermal coupler... the pilot light must be lit for several min to open the coupler so the pilot light will not go out.... the newer systems use an electronic ignition and no pilot light and need power to autostart but the coupler may be gone if you are holding that pilot start button down for several min and the pilot light is still going out..ps.. leave it in pilot mode for several min after initial start up before turning turning full burner operation operation operation operation operation operation operation it will snuff out the pilot light.

May 18, 2016 | Water Heaters

1 Answer

Pilot light will not stay lit on GE 40 gal. gas water heater tank


You have tank-type gas water heater:
Gas water heaters need working thermocouple, adequate incoming fresh combustion air with no trace amounts of chemical, open vent to outside that drafts poison combustion product upward, clean burner tubes and combustion parts, correct gas pressure with no air in line, working gas control valve thermostat, no lockout condition such as tripped ECO caused by runaway heating and dirty combustion parts, and no lockout condition such as exposure to flammable vapors.
Open following links for troubleshoot resources:
http://waterheatertimer.org/How-to-install-gas-water-heater.html#troubleshoot

http://waterheatertimer.org/pdf/Pilot-light-will-not-stay-lit.pdf
http://waterheatertimer.org/pdf/Attic-Ventilation-and-Pilot-Outage-in-Gas%20Water-Heaters.pdf

http://waterheatertimer.org/images/Water-heater-in-attic-800.jpg
http://waterheatertimer.org/images/Test-water-heater-vent-1400.jpg

Jul 30, 2011 | General Electric Water Heaters

1 Answer

Hot water heater pilot is off. It's not gas,


You have tank-type gas water heater:
Open following link to watch thermocouple replacement.
Make sure new thermocouple sits into pilot flame. Instructions for relighting water heater are usually printed on side of tank.
http://www.youtube.com/watch?v=v0aBPsNg6vo

Gas water heaters need working thermocouple, adequate incoming fresh combustion air with no trace amounts of chemical, open vent to outside that drafts poison combustion product upward, clean burner tubes and combustion parts, correct gas pressure with no air in line, working gas control valve thermostat, no lockout condition such as tripped ECO caused by runaway heating and dirty combustion parts, and no lockout condition such as exposure to flammable vapors.
Open following links for troubleshoot resources:
http://waterheatertimer.org/How-to-install-gas-water-heater.html#troubleshoot

http://waterheatertimer.org/pdf/Pilot-light-will-not-stay-lit.pdf
http://waterheatertimer.org/pdf/Attic-Ventilation-and-Pilot-Outage-in-Gas%20Water-Heaters.pdf

http://waterheatertimer.org/images/Water-heater-in-attic-800.jpg
http://waterheatertimer.org/images/Test-water-heater-vent-1400.jpg

Jul 29, 2011 | Whirlpool Water Heaters

2 Answers

Pilot light will not stay lit.


More than likely the thermal couple is defective. The thermal couple is a safety device that shuts the gas off if the pilot goes out. If it is defective the pilot light will not stay lit. The thermal couple is the device that the small copper line goes to. It is mounted beside the pilot flame and the flame much touch the TC for it to work. If the flame is not touching the TC bend it until it is in the flame. If it is touching the TC then replace it.

Jul 28, 2011 | Whirlpool Water Heaters

1 Answer

Rheem #22DV50-38,pilot light keeps going out.Thermal coupler has been changed.


Most gas water heater problems can be solved by cleaning burner parts and combustion chamber, and bleeding air out of gas line, checking gas pressure, and making sure gas shut-off handle is turned-on and parallel with gas line:
Many things cause pilot light to go out including dirty parts, air in gas line, and hot-unventilated atmosphere.
Open following links for troubleshoot resources and cleaning illustrations.
http://waterheatertimer.org/How-to-install-gas-water-heater.html#troubleshoot
http://waterheatertimer.org/pdf/Pilot-light-will-not-stay-lit.pdf
http://waterheatertimer.org/pdf/Attic-Ventilation-and-Pilot-Outage-in-Gas%20Water-Heaters.pdf

Jul 08, 2011 | Rheem Water Heaters

1 Answer

Cant get the pilot light to stay on, I have changed the pilot assembly


change the thermo coupler it tells the unit when the pilot is lit hope this helps bob

Apr 27, 2011 | Reliance Natural Gas Water Heater Control

1 Answer

Pilot liht wont stay lit on hot water heater.


You will need a new thermo coupler to keeep the pilot ight on. It is a probe that touches the pilot flame to sense the the regulator to feed the gas flow. Upon failing it shuts off the gas to the regulator so the unit does not catch on fire. In other words it is a fail safe part that is required

Apr 12, 2010 | Water Heaters

3 Answers

Pilot light on water heater wont stay lit


The thermocouple has failed. It is the temp probe that goes from the pilot lite burner area to the control valve. Go to your local plumbng repair shop and buy one. Most appliance parts stores have them also. Take the old one with you and they will hook you up with an exact replacement. They are not that hard to change. Usually a nut or 2 screws in the temp bulb area at the burner end and a nut that threads into the control valve.
Make sure before you install the new one that the area where it mates to the gas valve is clean. Should be about a 20 min job including clean up with replacement parts in hand.

Jan 23, 2010 | Rheem 40 Gallon FVR NATGAS Low WATER...

2 Answers

Pilot wont stay lit


Check the thermocouple,Its is a flame senser.It will not stay lit if it is bad.

Oct 04, 2009 | Water Heaters

Not finding what you are looking for?
Water Heaters Logo

Related Topics:

120 people viewed this question

Ask a Question

Usually answered in minutes!

Top General Electric Water Heaters Experts

paulcarew

Level 3 Expert

2519 Answers

Donni Steen

Level 3 Expert

659 Answers

yadayada
yadayada

Level 3 Expert

76164 Answers

Are you a General Electric Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...