Question about Intermatic Malibu 300W Power Pack Transformer ML300RTW

Open Question

INTERMATIC TIMER MOTOR WG1770-1 NOT WORKING - Intermatic Malibu 300W Power Pack Transformer ML300RTW

Posted by Anonymous on

4 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 52 Answers

SOURCE: I have an intermatic t10404r pool timer, and only one timer works

The problem might be the trips.

Posted on Feb 25, 2010

SOURCE: I have intermatic timer T30003R. How do I change

My understanding is this timer uses typical T100 series 120Volt clock motor.
The motor has identifying numbers printed on it.
T100 series 120V clock motor is available at Grainger:
http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK1?Pid=search
Selection of Intermatic clock motors are available on-line:
http://www.electricsupplyonline.com/prod/intermatic-motors.php

To replace motor:
Timer mechanism snaps out of box using a thumb-spring located at top of mechanism.
Clock is located on back of mechanism, and is held by 2 star-screws.
You can buy star screwdriver bit at auto parts store or hardware.
Clock motor has two white wires that are connected to terminals on front of timer.
Be sure to tighten terminals screws very tight after replacing clock motor.

Posted on Jan 10, 2011

SOURCE: What timer motor fits in Intermatic ML121RT Power Pack ?

The PB912M10 timer clock motor is not sold separately. Aug 2010.
If power pack transformer still works: buy cheap plug-in timer, set power pack to override, and plug power pack into cheap timer.
With receipt, power pack might still be under warranty.
Open following link for power pack tips and resources:
http://waterheatertimer.org/Malibu-power-pack-stopped-working.html

Posted on Aug 23, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The clock on my paragon 4004-71m is not working


1) Clock motor has gone bad, but replacement clock motors are no longer made.
Copy following link for Paragon resources:
http://waterheatertimer.org/Paragon-timers-and-manuals.html

2) Paragon is not making parts or replacement motors.
4007-41 is 240Volt timer, replace timer with Intermatic T104
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html

3) Crossover wiring from Paragon 4004-71 to Intermatic T104:
Paragon 1 to Intermatic 1
Paragon 2 to Intermatic 2
Paragon 3 to Intermatic 4
Paragon 4 to Intermatic 3
Intermatic terminal A is generally not used for 240Volt

4) Add a comment if needed

Jan 17, 2013 | Paragon Hardware & Accessories

1 Answer

Manual switch works timer doesn't.


Timer that worked before and stopped working: could be clock motor or trippers
New timer installation: possibly the wiring from breaker box and wire to Load are reversed.

Open following links to troubleshoot Intermatic timer.
http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timer.html
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html

Jul 27, 2011 | Intermatic & Indoor/Outdoor Rain Tight...

1 Answer

I need timer motor for paragon mod# 7007-00


1) Open following link for Paragon timers and manuals:
http://waterheatertimer.org/Paragon-timers-and-manuals.html#7000

2) 7007-00 is 4PST timer with 120Volt clock motor.

3) M3099-00 120Volt clock motor for 7000 series is available at Invensys for $32.24
http://www.energyequipment.com/p-88069-invensys-climate-controls-m3099-00.aspx
3 to 4 weeks lead time.

4) Intermatic replacement is T7401B
40 amp 7-day timer with 125 volt clock motor, 4 independent loads, each load turns on-off at same time
http://www.intermatic.com/~/media/files/intermatic/products/instructions/timers/t7401b%20-%20english.ashx
Intermatic at 1000 bulbs 135.52
http://www.1000bulbs.com/product/3377/ELEC-T7401B.html
Intermatic Amazon 122.00
http://www.amazon.com/Intermatic-T7401B-7-Day-Switch-Steel/dp/B000GHN9JG

5) If you want 30 amp electronic timer with 4 independent programmable circuits that can turn on-and-off with different schedules, then Intermatic ET70415CR for $700+

Upvote the help.
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

May 10, 2011 | Hardware & Accessories

1 Answer

I noticed the Tork 1104 timer box was not working. It does not make a sound. And the clock does not move. I measured the incoming and outgoing wires with a multimeter and both measure at 240V. I'm...


13 years is good run for clock motor. Timer will last longer than clock motor.
Open following link to identify timer
http://waterheatertimer.org/Tork-timers-and-manuals.html#1101
Tork 1104 has 240Volt clock motor

Frontier lighting sells the >> 120V Tork motor: List price 40.33/ your price 45.49
So 120Volt replacement motor costs as much as new replacement timer
http://www.frontierlighting.com/product.jsp?part=10431&process=search&show=&&gdftrk=gdfV22514_a_7c834_a_7c3267_a_7c10431

Intermatic replacement is240 volt T104 timer for $49.62 with 'free' shipping:
Also Intermatic trippers and clock motors are cheap and easily available
http://www.amazon.com/Intermatic-T104-208-277-Volt-Mechanical-Switch/dp/B000BQOX88
Crossover wiring from 1104 to T104.
Tork L goes to Intermatic 1
Tork 1 goes to Intermatic 3
Tork x goes to Intermatic 2
Tork 2 goes to Intermatic 4
Intermatic A is not used unless you have neutral wire or 277V
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html

GE sells the same 240Volt Tork timer under GE model 15307 in indoor-outdoor enclosure available at Home Depot for $59.00. Year 2011, GE does not pay US income tax, but takes US profits and pays tax in foreign nations. No replacement clock motor is available, but crossover wiring is same.
http://waterheatertimer.org/GE-timers-and-manuals.html#15306

Upvote the help.
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

May 09, 2011 | TORK Variable Cycling Timer 8601

1 Answer

Clock dial doesn't move


You posted under Intermatic outdoor sprinkler timer.

Intermatic clock motors can be replaced.
Clock motor has identifying numbers printed on motor.
Tip mechanism out of box using thumb spring located inside box at top.

Google search for that motor number, for example WG1573 is 240V clock motor for T104 timers.

Aplus sells Intermatic clock motors:
http://www.aplussupply.com/intermatic/timermotors.htm
Electric supply sells clock motors
http://www.electricsupplyonline.com/prod/intermatic-motors.php
Intermatic online store is expensive option:
http://www.intermaticstore.com/

Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, expert speaks with you over phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Feb 10, 2011 | Intermatic T8845PV - Sprinkler-Irrigation...

1 Answer

Timer not working. the rotating timer stops at the setting


Sounds like the clock motor has gotten weak.
You can replace Intermatic clock motors.

Snap out insides of timer and clock motor is located on back.
Motor has numbers printed on it that identify specific clock motor.

Motor is removable with small star screwdriver bit.
Clock motor has white wires that attach to terminals on front of mechanism.
Re-attach new clock to same terminals and tighten screws very tight.

If you have T101 or T103 timer, Grainger sells 125V clock for $16
If you have T104 timer, Grainger sells 208-277V clock for $16
http://www.grainger.com/Grainger/timer-accessories/timers/electrical/ecatalog/N-8hi

You can google search your specific clock motor number:
Clock motors also appear on links below:
http://www.electricsupplyonline.com/prod/intermatic-motors.php
http://www.aplussupply.com/intermatic/timermotors.htm

Dec 24, 2010 | Intermatic & Indoor/Outdoor Rain Tight...

1 Answer

My Intermatic timer is not working. I replaced the WG1573-10D motor but still it does not work. The manual override works so the power supply is ok. Any suggestions welcome.


Your question doesn't provide enough information.

You have 240Volt T104 Intermatic timer?
A) WG1573 is for 240 volt timer. If you have T101 or T103 timer, it takes 125V clock motor.
http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK1?Pid=search

B) This is new installation? and clock motor only worked when override was ON, so you bought new clock motor. But actual problem is that wires from Load and Breaker are reversed.
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html

C) Your timer worked fine in past years, but dial stopped rotating so you bought new clock motor?
You replaced clock motor.
Manual override works.

--And then your information ends.
Does clock motor work? Does the dial turn? Are your on-off trippers on the dial?
Are tripper worn down?
Buy new trippers.
http://www.grainger.com/Grainger/INTERMATIC-Timer-Tripper-2E054?Pid=search

If clock motor does not work, and circuit is 240Volts, then I suspect you connected clock motor to wrong terminals>? Clock motor connects to terminals 1 and 3.

Add a comment and fill in details so we can properly troubleshoot.

Dec 04, 2010 | RTO Intermatic Inc Wg1573-10d Replacement...

1 Answer

Intermatic timer for my pool pump - clock is not running


Usually the timer motor is bad when that happens. Replacement timer motors are available from websites like this one:
http://www.aplussupply.com/intermatic/timermotors.htm

Be sure to get the right voltage timer motor. Intermatic T101's and T103's use a 120 volt timer motor (Cat# WG1570) and the T104 uses a 240 volt timer motor (Cat# WG1573).

If you don't want to mess around replacing the timer motor, you can purchase a new timer, and as long as the existing enclosure is in good shape, just swap out the guts.

May 12, 2010 | Intermatic & Indoor/Outdoor Rain Tight...

Not finding what you are looking for?
Intermatic Malibu 300W Power Pack Transformer ML300RTW Logo

Related Topics:

75 people viewed this question

Ask a Question

Usually answered in minutes!

Top Intermatic Hardware & Accessories Experts

Gene Haynes

Level 3 Expert

5089 Answers

Jay Finke
Jay Finke

Level 3 Expert

1338 Answers

Steve

Level 3 Expert

3287 Answers

Are you an Intermatic Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...