Loud noise when furnace starts but furnace won't come on.

We have a York furnace model number P3CGD12N08001B. The furnace sounds like it is going to start then a loud noise starts we have to manually shut off furnace to make it stop. Pilot light is on. Fan will move if you turn it but will not kick on when furnace comes on. Furnace is on but the fan/blower won't come on. What is wrong with it? Does it just need to be cleaned out.

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 3,361 Answers

Your fan delay relay has failed and must be replaced.

Posted on Feb 25, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Where is the furnace filter located on the York P3CGD12N08001B


Residential furnaces have exterior filter boots supplied by installer, commercial york units have filter access doors. If this is a roof top unit your filters would be in the door to the left of the blower compartment.

Nov 18, 2009 | York Yankees Bedding MLB Comforter

2 Answers

Condensation from small blower shorts out circuit board.


Put a plastic bag over the control board that will allow it to breath. you can add sealant to joint but you should clean the old off first. Then use some cork tape after sealant dries. You may also use pvc glue but it will never come out after that, but can be cut w/ saw if that becomes nessary.

Feb 01, 2009 | York Yankees Bedding MLB Comforter

1 Answer

York high effenciency furnace not firing all the time


has anyone worked on this furnace because the error would indicate that the positive 120 volt and the neg 120 volt is swapped , these units will also do this when the ground wire to the furnace or gas valve or furnace or @ the panel is lose , corroded , or missing , the gnd must be present to open valve , I am aware that ac is is not usually polarity sensitive but in this case it most certainly is ...have seen many time and know it to be true

Dec 27, 2008 | York Yankees Bedding MLB Comforter

1 Answer

Owners Manual


York Corporate Headquarters
631 South Richland Ave.
York, PA 17403
Phone: (717) 771-7890

Contacting York
Mail:
York International Corp.
P.O. Box 1592
York, PA 17405-1592
USA
Phone: (877) 874-7378


York Website


York was purchased by Johnson Controls in 2005
Johnson Website.

I cannot find an actual manual online. I hope this information helps you. Good Luck.

Dec 27, 2008 | York Yankees Bedding MLB Comforter

1 Answer

Heat pump wiring


yes i can , you need to hookup the r and the o together so that the reversing vvalvce is allways energized . so with that im mind send r,y,c,o to theout side unit. at the ahu you'll hook up the 5 wires for the furnace, r g w1 w2 com and at the thermostat r,w1,w2,y,g,com,o then you will be set (the o get hooked up to o and goes straight out side.

Dec 03, 2008 | York Yankees Bedding MLB Comforter

Not finding what you are looking for?
York Yankees Bedding MLB Comforter Logo

871 people viewed this question

Ask a Question

Usually answered in minutes!

Top York Sport & Outdoor Experts

paulcarew

Level 3 Expert

1897 Answers

Brandon Berry
Brandon Berry

Level 2 Expert

407 Answers

ray gallant

Level 3 Expert

36333 Answers

Are you a York Sport and Outdoor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...