Question about Heating & Cooling

Open Question

MY Rinnai heater got unplugged while it was running and now it will not turn back on. There are no lights and will not do anything.

Posted by on

  • 2 more comments 
  • Bandy Ringgard Dec 12, 2012

    I am in a mountain town in Colorado and the only heating repair guy has not called back. Brrr, HELP!

  • Bandy Ringgard Dec 12, 2012

    It is an ES38 and I took the front cover off. I dont think the 5A fuse is blown and I dont see any other fuses?

  • Bandy Ringgard Dec 13, 2012

    Well, I'm awesome and fixed it myself. Just in case anyone else out there has this problem and Rinnai cutomer service cannot help you, this is what I did: I unplugged the unit and turned off the gas. I took the front off and unplugged the wires going to the controls and plugged them back in. I made sure the fuse was not bad and that it was tight. I plugged it back in and turned the gas back on. FIXED. Glad I didnt waste money on a service call. I cant beleive the customer service at Rinnai did not suggest this. Hmmm.

  • Bandy Ringgard Dec 13, 2012

    Do I get points for solving my own problem? ;)

×

Ad

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
  • 53 Answers

SOURCE: I have a Rinnai 308FTR heater and the first time I

Means failed ignition/no gas.
Check gas supply.

Posted on Jul 17, 2009

Ad
roniecon
  • 6826 Answers

SOURCE: NO HOT WATER N THE PILOT NOT LIGHTING UP

The thermocouple has gone bad.The thermocouple needs to be directly in the pilot flame.When the thermocouple goes out,the flame most of the time will have burned the thermocouple tip a way.If it was not for this devise,the gas would exscape,and fill the home up.This is a safety feature.

Posted on Oct 20, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have Rinnai natural gas room heater 516tr. It's continuously showing filter light on indication. I have clean heater but still filter light kept on. What I should do?


Turn the heater OFF and unplug it from the wall. Remove the filter and reinstall it, making sure it's fitted properly into the heater. Wait 5 minutes and plug the heater back ion and turn it ON. You may have to reset the controls back to way you had them. Completing what you just did, should have allowed the heater reset itself and function as it should. If this sort of thing continues to reoccur, contact your local Rinnai Dealer for service.

Hope this helped you to solve the problem.

May 01, 2011 | Heating & Cooling

1 Answer

Why does red light on "on" button stay on?


Hello,
The reason the red light on your rinnai vent free gas heater stays on simply is because it is having power on it, if it is unplugged, it will go off, or if you turn off the switch from the power outlet, then it will go off too.
As long as there is power supplied to the rinnai vent free gas heater, the power light will remain on.
Take care and good luck

Dec 01, 2010 | Rinnai Vent Free Gas Heater/: 6,000 BTU...

1 Answer

Error EE 8 is showing what could be the problem???


EE 8 indicates a problem with the combustion blower. If the blower is running the problem is with the sensor. Make sure the wires for the sensor haven't come unplugged. If the sensor is bad, you will need a new blower. If it isn't running then the problem may be soot and carbon build up on the exhaust fan blade. You will have to remove the fresh air hose on the back of the heater or the rubber boot inside the heater to reach the fan blades. Use your finger or something to reach in and turn the fan blades. You may hear the sound of the carbon breaking loose. Turn it until it spins freely. Let me know if you need anything else.

Nov 15, 2010 | Rinnai Toyostove Direct Vent Heater:...

1 Answer

Rinnai 1004 F Error Code 11


Code 11 is that the unit is trying to light but does not sense a flame after 5 seconds. Usually means you have run out of gas if you are bottled gas. Check your bottles are turned on if you are on LPG, you might need to change over manually. Have you anything else on gas?

Jul 01, 2010 | Rinnai RHFE-1004FA 38,400 BTU Energy Saver...

1 Answer

I have a rinnai heater and it stopped working all


rinnai, toyostove and monitor heaters are basically all the same. first you have to make sure your fuel valve is open at the tank. next you have to reset the tank lockout on the sump. then set your set point higher than your room temperature. now press on. the unit will go through a 300 second purge cycle. the pot heater should turn on when the purge cycle starts. after the purge cycle the fuel pump turns on and pumps fuel into the pot. when it vaporizes the igniter lights it. when a flame is detected the flame rod says ok to keep running so the fuel pump shifts into high speed. when plenum temperature reaches a preset level the fan turns on.

Oct 17, 2009 | Rinnai Toyostove Direct Vent Heater:...

1 Answer

Won't turn on or up


If there is a 'lock' button on the heater, push and hold till the green light goes out.
otherwise www.rinnai.co.nz - tradesmart, energysavers.

May 28, 2009 | Rinnai RHFE-1004FA 38,400 BTU Energy Saver...

2 Answers

Rinnai Energysaver 1004F on indicator light is red (usally green)


If its not producing heat, yep! If it is, it indicates that there is an error code stored in memory.

Feb 18, 2009 | Rinnai RHFE-1004FA 38,400 BTU Energy Saver...

1 Answer

Rinnai RHFE 1001FA


i have a rinnai rhfe 1001fa heater and when its real cold sometimes it will shut down all the lights go out and i have to shut it off then turn it back on and sometimes it still wont start and i will leave it of for a day or two then try it and it will work it seems to act up more when its colder i am running it this fall so far no problems this unit is around a 1994 or so and has not given any trouble till this started last winter

Mar 11, 2007 | Rinnai RHFE-1004FA 38,400 BTU Energy Saver...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

30 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2514 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides