Question about Home

1 Answer

Redout on jacuzzi spa model j340 has --- code.has been working

Spa has been working fine until this weekend when code was found.can you give advice on how i may be able to repair myself.I am handy with most projects.
thanks for help

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 7 Answers

The condition you see on the topside control is known as "watchdog" Which usually means that the spa thinks it's "overheating"
Turn off the power to the spa for a couple of minutes, then restart, Watch the topside control if the temp. starts to climb & read a lot hotter than the actual water temp. Then it goes into watchdog, most likely you have a bad temp sensor. In some cases just resetting the spa will clear the watchdog & everything works fine. (Voltage fluctuations, "spikes" can freak out the electronics & the tub goes into watchdog to protect itself) If the spa immediately goes into watchdog when you reset it, you might have a bad board. (Let's pray it's not) 90% of the time it's a bad temp. sensor.

Posted on Jan 14, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My jacuzzi J340 2002 is flashing the code FLO2. What happens if I continue to run the tub with this code displayed? Thanks to anyone that can help me.


flow switch error code, malfunctioning closed. do not use until you have rectified the error. use a jacuzzi authorized repairman/woman.

Jan 01, 2017 | Jacuzzi Home

1 Answer

I have a J340 Spa that is throwing the watch dog mode --- error code. I have replaced the temp sensor and the circuit board. Can a malfunctioning circulation pump cause this problem. Thanks.


yes, it can as can the hi-limit as well.

Is the watchdog, consistent or does it show up every now and then?

If not consistent: then it is an indication that there is a "Potential" problem, not necessarily always indicating a problem is there. Power fluctuation will cause this as well.

You may need to monitor for a while.

May 21, 2014 | Jacuzzi Pool & Spa

1 Answer

I have a Jacuzzi J340 Hot Tub. I am having trouble with the heating. When the pump is on, the water circulates just fine. once the heater kicks on, it runs for about 10 seconds, then clicks to OH, and...


make sure the heating element isnt touching the casing inside the heating tube. if its an indoor tub, make sure the filtration cycles are not set to constant. constant filter cycles on an indoor tub will generate residual heat from the circ pump running 24/7, causing tub to heat past 104 degrees

Sep 15, 2013 | Jacuzzi Pool & Spa

1 Answer

Jacuzzi hot tub, Water is too hot. Heats until it trips the system. I have replaced the analog temperature control,


1) Safety question first
Why hasn't the GFCI tripped.
If your spa is not protected by ground fault., then you are at serious personal risk.
http://waterheatertimer.org/How-to-wire-GFCI.html#arc-fault

2) Replace the element.
http://waterheatertimer.org/How-to-test-water-heater-element.html

3) If element is cracked, it can continue heating to ground wire, causing runaway heating.
This applies to spas, and water heaters of all type.

Dec 08, 2012 | Jacuzzi Pool & Spa

1 Answer

My hot tub top control is flashing SPA6,and hot tub is not heating up.


Here is a link for you to resource that error code.
click that link and scroll through them until you find your error code.

Rod
US Parts Center

Aug 19, 2012 | Jacuzzi Pool & Spa

2 Answers

Can't unlock jacuzzi hot tub control panel


control panel not working, cannot control or work control buttons, stays in econ mode all the time. Nothing else works.

Nov 27, 2010 | Jacuzzi Pool & Spa

1 Answer

I have a Jacuzzi Z 145 spa. I was constantly getting an FL error. Purchased a new switch, put it on and when I turn the spa on I immediately get a circuit blow. What could be causing this problem?


Its possible your heater has a ground fault. If the old pressure sw was giving the FL code the system would not send power to the heater. Now with the new sw working power is being sent to the heater.

Oct 23, 2010 | Jacuzzi Pool & Spa

1 Answer

Jacuzzi Laser II: Problem with the Heater/filter setting. The jets come on when it's on this setting. When I turn it to Filter setting it's fine..when I turn it off the jets come back on What gives?


The jets will run while in the filtration / heating mode. If the spa is in the middle of the filtration cycle, the jets will stay on until the cycle time runs out. So, if the spa jets are on during this time, they are on for the full duration, 2-6 hours every 12. You can cycle the jet button to high, but when you try to turn them off, they will just go back on low.

Jan 23, 2010 | Jacuzzi Cyget In Ground Pool Pumps

1 Answer

Jacuzzi - GFCI keep tripping prventing Jacuzzi from starting Jacuzzi Whirlpool Bath, model H240000


i have the same model after unplugging everything one by one i got the breaker to stay on with the transformer unplugged. ordered new transformer installed works great!!

Mar 28, 2009 | Jacuzzi ALADDIN GO-KIT14 JACUZZI MAGNUM...

2 Answers

Pump will not work in high speed


Only three posible problems. High is out on pump. Spa side control is out. Control box relay that runs high pump is out.Does upper controls(spa side) read out a code? Kirk

Feb 12, 2009 | Jacuzzi MAGNUM FORCE POOL PUMP - TWO SPEED...

Not finding what you are looking for?
Home Logo

Related Topics:

1,168 people viewed this question

Ask a Question