  • Pande Gruevski Dec 09, 2012

    The problem is. When the split system is set to cool , it just blows air not cooled but when set to heat no air blows in the inside unit. Both an electrician and a fridge mechanic installed it. They said that a Mitsubishi specialist can help me with the problem.

×

4 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 1 Answer

SOURCE: not working probly two flashs then pause

The two flashes are telling you what's wrong with the unit. Take the cover off of the unit inside(evaporator) and there should be a guide on the panel with the wiring diagram. On this diagram there should also be a solution to what each blink means. One blink means this, two blinks mean that, etc... Hope this is helpful.

Posted on Mar 14, 2009

heatman101
  • 43501 Answers

SOURCE: what is the refrigeramt capacity of the model

Hi,
Here is where you can find all the info you will ever need about Mitsubishi Air Conditioning units...
Check out this tip that I wrote about that...

Mitsubishi Air Conditioner Troubleshooting and Repair
http://www.fixya.com/support/r5643983-mitsubishi_air_conditioner

heatman101

Posted on Aug 20, 2010

  • 1 Answer

SOURCE: Mitsubishi split-type air conditioner model

Hi I have Mitsubishi split unit which is 5 years old. when turn heat mode for 30 deg C on the remote condesing unit runs for about 6 minuts and stops. what would be the Technical problem ?Thanks an Apprentice.

Posted on Mar 11, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have an mitsubishi msh 17d and i have lost the remote control hoa i can start it without the remote control?


Have you tried looking up a app on a smart phone. I use my Note 4 to control my t.v., cable box and bose stereo.

Jun 21, 2016 | Mitsubishi Heating & Cooling

1 Answer

I have a Mitsubishi Split model MSH-09NV but not turn on, and the leds are off. The Split not work with bottom emergency neither.


Ensure power supply is correct and you have correct live and neutral and Earth at unit, test power across live and neutral to see voltage at outdoor unit terminals

Dec 04, 2015 | Mitsubishi Heating & Cooling

1 Answer

Replacement part for Omron G3J-S245BL-MS Soft start relay for Mitsubishi MSH A30WV Airconditioner


Go to parts dept at dealer, if they don't carry it find an electronics store like Digi-key or Allied on-line, they probably carry Omron relays or can order it.

Nov 22, 2014 | Mitsubishi Cars & Trucks

1 Answer

Replacement remote for Mitsubushi aircon MSH-24TV, how do we get them talking?


If you wish to buy a genuine remote control, you have to contact the authorized service centre for Mitsubishi. If you wan to buy a universal remote control, you should first check, which brand remote control have setup codes to Mitsubishi brand TVs. If you wish to get this detail, try the links given here. It has setup code list, and setup procedure to many popular brand remote controls. Check and find out which brand remote control have the codes to Mitsubishi, and buy that one according to availability.
http://electrohelponline.blogspot.com/
http://electro-medical.blogspot.com/

Dec 24, 2013 | Televison & Video

1 Answer

I have a mitsubishi daiya model SRC56HAA have lost the manual don't know how to get the cooling working


Is it possible to control the Mitsubishi Daiya Split Type Indoor Unit Model Number FDUM321HKXE2 as follows. We have an energy management system that controls the power supply to the room. This is done by using a door contact via a mini PLC to close and open the system The room is powerd up, all electrics and A/C as soon as the door is opened and closed after a 10 min. delay when the person leaves the room. I am trying the regulate the A/C not to power up on entrance. I need it to operate after close down only by requiring a manual operation of the wall control unit, i.e. it must be switched on manualy at each entry. Any advice ??? Regards Bill

Nov 19, 2010 | Mitsubishi MS17TN Air Conditioner

2 Answers

Mitsubishi split-type air conditioner model MSH-26SV. When the unit is switched on, the 2 green lights on the front panel light up normally but but the unit doesn't work at all and, after a few minutes,...


Hi I have Mitsubishi split unit which is 5 years old. when turn heat mode for 30 deg C on the remote condesing unit runs for about 6 minuts and stops. what would be the Technical problem ?Thanks an Apprentice.

May 23, 2010 | Mitsubishi MS09TW Air Conditioner

1 Answer

What is the refrigeramt capacity of the model


Hi,
Here is where you can find all the info you will ever need about Mitsubishi Air Conditioning units...
Check out this tip that I wrote about that...

Mitsubishi Air Conditioner Troubleshooting and Repair
http://www.fixya.com/support/r5643983-mitsubishi_air_conditioner

heatman101

May 18, 2010 | Mitsubishi MXZ30TN Air Conditioner

1 Answer

Air not cold...model MSH-18NV no operating manual for remote . Not sure how to set to cool air when remote reads "I feel..." choices are cool dry or warm but when set on cool 20degrees, luke-warm air blows...


Hi FixYa team. After about 2 hours on the internet I managed to find a PDF file of the operating manual for my air con.
Thankyou for your prompt response. I'll be using your services again!

Jan 11, 2010 | Mitsubishi Heating & Cooling

1 Answer

Not working probly two flashs then pause


The two flashes are telling you what's wrong with the unit. Take the cover off of the unit inside(evaporator) and there should be a guide on the panel with the wiring diagram. On this diagram there should also be a solution to what each blink means. One blink means this, two blinks mean that, etc... Hope this is helpful.

Mar 14, 2009 | Mitsubishi Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

340 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2458 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...