Question about Hitachi C10FSH 10" Dual Bevel Slide Compound withLaser

1 Answer

The laser light doesn't work on the hitachi c10fsh

Posted by on

  • tommyverardi Apr 29, 2009

    What coin battery? Laser marker does not work

×

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 7 Answers

Take the unit off your saw. There should be a removable back side that will allow you to replace the coin battery inside the unit.

Good Luck!

Ben

Posted on Jan 12, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Can not get brush,s out ,soaked with rust remover and tried the pick ,how do you remove armature ?


The carbon brush buying Hitachi are often made of bakelite (thermoset plastic) that are able to rupture completely exactly by half.

If that is happens try both halves exactly to get on each other that is to say to press toward each other with a drop of super glue solely in the middle then tightly around a piece of double-sided adhesive tape, after some time in order to turn the appropriate screw driver that he has some support to the adhesive tape if thats not the problem and you mean the carbon brushes if they are stuck in the brush holders do nothing not pull on the brass litz wire it is not tight first remove the motor housing.and pust the brushes from the middle out slowly back careful against the direction of the spring of the brush so if becomes loose remove them and clean it with solvent that its dry or buy new ones
https://devs.hitachi-koki.co.jp/ois/explodedDiagram.html?type=svg&modelName=C+10FSH&newwindow=true

Jul 08, 2015 | Hitachi C10FSH 10" Dual Bevel Slide...

1 Answer

How do i know which wires to connect for a c10fsh hitachi miter saw switch


You may have to contact Hitachi (or a Hitachi repair center) to get connection information.

Feb 21, 2015 | Hitachi C10FSH 10" Dual Bevel Slide...

1 Answer

Won't start after install of new trigger


Hi There

1; Is the power going to the switch first of all?

2; Do you get a reading of voltage coming out of the switch?

3; If 1 & 2 are ok check the inside of the housing and make sure the spring connections on the brush holders are ok and that the brushes slide through the brush holders smoothly.

4; Check continuity of both sides of the field.

5; Check power goes to the brush holders.

If you do not get any reading from the above that's where the problem lies.

Apr 17, 2014 | Hitachi C10FSH 10" Dual Bevel Slide...

1 Answer

Braking on miter saw not working


Try fitting a new set of brushes first otherwise it could be that it needs a new field coil.

Dec 27, 2013 | Hitachi C10FSH 10" Dual Bevel Slide...

1 Answer

Which wires go into the trigger, 2 have a reistor type thing on them, there are 2 lower and 2 higher spots on te new trigger


I have a wiring diagram and drawings PDF file I can let you have. send me your email address to sales@oasistools.co.uk

Jan 29, 2013 | Hitachi C10FSH 10" Dual Bevel Slide...

1 Answer

How do you remove the brushes on a Hitachi C10FSH compound miter saw?


On the sides of the motor housing there are two small, black screw caps about as big around as a dime. By removing those the brushes will come out. Most come out easily but if they are in very tight, be carefull not to strip out the screw driver slots. The caps are made of a hard plastic that breaks easily and if the slots are stripped out they are very difficult to remove.

Sep 18, 2012 | Hitachi C10FSH 10" Dual Bevel Slide...

1 Answer

AFTER NOT USING MY HITACHI C10FSH FOR A YEAR OR SO. I TURNED IT ON YESTERDAY AND I HIT THE TRIGGER AND IT STARTED, I THEN SET UP MY CUTS AND IT WOULD NOT START. AFTER CHECKING THE POWER SOURCE, I PRESSED...


with the tool unplugged check that the two carbon brushes are free in the holders . remove the two caps locking them in and take them out , blow out and replace . be careful make sure when putting them back in that the caps do up nice an free. possibly dust stopping brushes from making contact to armature .

Aug 16, 2011 | Hitachi C10FSH 10" Dual Bevel Slide...

1 Answer

I do not have a compound saw, just a regular Hitachi skill saw. Often when I'm cutting through wood, the blade will suddently stop with trigger depressed. I can back it up and it immediatly starts again....


I would suggest 2 things... first check that your blade is tight... and second make sure that your power supply is adequate...no long skinny cords or sharing outlets

Jun 10, 2010 | Hitachi C10FSH 10" Dual Bevel Slide...

Not finding what you are looking for?
Hitachi C10FSH 10" Dual Bevel Slide Compound withLaser Logo

Related Topics:

491 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hitachi Circular Saws Experts

Pieter Vleeshouwers

Level 3 Expert

1420 Answers

Jay Plesset

Level 3 Expert

2808 Answers

John Mock

Level 3 Expert

932 Answers

Are you a Hitachi Circular Saw Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...