1 Answer

Reset keeps triping

I have a aqua star 250sx lp water heater that the reset button keeps tripping. seems to be with high water flow. i have looked for a manual but no luck help

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 700 Answers

Http://www.boschhotwater.com/HelpfulResources/TechnicalSupport/BoschAquaStarModels/250SXTechSupport/Troubleshoot/tabid/563/Default.aspx
click on this link and it has the troubleshooting in strucktions for the unit . hopt that it helps you out.

Posted on Jan 11, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have norton tankless water heater, and the reset keeps getting tripped... what can cause this?


It can be the breakers in your house or the reset button is malfunctioning

Aug 23, 2012 | Water Heaters

1 Answer

Aqua star runs on and was running water to out side I guess it would be the overflow ( tankless). Had to turn the water off


Problem is not clear

Before calling service technician, open following link for Bosch troubleshooting resources including contact information for Bosch:
http://waterheatertimer.org/Troubleshoot-Bosch-Tankless-water-heater.html

Jun 09, 2011 | Bosch 2400ES LP AquaStar 6.4 GPM Indoor...

1 Answer

Looking for a flow sensor for Aqua Star 240 FX


Hi,

Here it is..

http://www.lowenergysystems.com/b2c/ecom/ecomEnduser/items/xt_itemDetailNF.aspx?itemNum=EK034&siteId=1&bulkexists=0

The Tagaki TK-1 is the same unit and the parts are interchangeable...

heatman101

Mar 16, 2011 | Bosch Water Heaters AquaStar - Tankless...

2 Answers

The therostat breaker keeps triping no mater what the therostat setting is. I have to reset the breaker each time i want hot water. Is this GE solution to save energy?


It sounds like the thremostat may be shorting out they are not to exspensive to replace.

It it constantly triping there is a wire touching somewhere.

May 16, 2010 | General Electric GE SmartWater Household...

1 Answer

I have a 250SX aquastar Bosch tankless hot water heater . It keeps going out on EC code; whats wrong? Also I've been running the unit for about a 9 months without hooking up the condensate dain line.


The 250 MUST have the condensate line connected. EC comes from gas supply problems and CO2 levels not being adjusted. LP units require 3/4" smooth gas pipe or 1" corrugated pipe minimum size. The LP regulator needs to be turned up to about 13 inches of water column and with all the gas appliances on, measure no less than 11 inches of water column. The CO2 levels must be measured by a qualified gas technician with a calibrated (with in 6 months) CO2 analyzer.

Mar 20, 2010 | Bosch & Tankless LP Hot Water Heater

1 Answer

No heat, no light, has flow and power?


I'm experiencing the samething it's been installed 3 years and christmas day nothing. Please help.

Feb 07, 2010 | Bosch & Tankless LP Hot Water Heater

1 Answer

250sx quit working. Gas o.k. water flow good, throws ea code after 3 start attempts. 1. where is the ionization electrode, and is the fan supposed to come on before ignition? Fan comes on afterea code....


The gas pressure must be increased at the regulator from 9 inches of water column to about 12.5-13 inches of water column. The CO2 levels need to be adjusted for each installation. The air intake MUST come from outside the same wall as the exhaust. I have never seen any manufactures tankless unit installed properly. Plumbers do not read the manual.

Jan 24, 2010 | Bosch & Tankless LP Hot Water Heater

1 Answer

I have a aqua star 250sx lp tankless water heater that i have to keep resetting. seems to trip when the water flow is high i tried to look for a manual but no luck. help thanks brian


you should have no more then 75lbs of water pressure going thru the unit and min of 60lbs these are the pressures they are designed to work under, you may have to add a regulator to the system

Jan 11, 2009 | Water Heaters

Not finding what you are looking for?
Water Heaters Logo

Related Topics:

255 people viewed this question

Ask a Question

Usually answered in minutes!

Top Bosch Water Heaters Experts

Steven Foerst
Steven Foerst

Level 1 Expert

52 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

21949 Answers

Raygin
Raygin

Level 2 Expert

322 Answers

Are you a Bosch Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...