It's a classical error code, you can find all the error codes together with the troubleshooter within the manual under this article:
Bosch Axxis Washer Manual

Posted on May 27, 2015

5 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 8 Answers

SOURCE: Bosch Axxis WTL 5400 Electric Condensation Dryer...Lint Filter Light

have you checked the vent line it could be stopped up if the line is bent same affect as the lint filter being full

Posted on Dec 15, 2007

  • 11 Answers

SOURCE: Dryer drum will not turn

check to see if there is a little red button on the back if so push it in thats your re-set button

Posted on Mar 24, 2009

  • 51 Answers

SOURCE: WTL 5410 BOSCH AXXIS CONDENSATION ELECTRIC DRYER

the thermostats at the element have to be replaced, they burn out prematurely if the condensor unit is not cleaned on a regular basis.

Posted on Feb 02, 2010

farfield
  • 462 Answers

SOURCE: Our dryer will turn on, but won't actually

I assume it runs and this is from that stance. If it doesn't the motor has to be checked and the power coming in. In fact the dryer can run and still not have the correct power to opperate the heater.

A dryer has to have 2 things to dry clothes. 1 Air supply and exhaust, 2 Heating source. No mater if its a gas dryer or electric these 2 items are what dry the clothes..


A. If the dryer has all of these things it has to be heating and an air flow problem (kinked or dirty dryer duck, motor fan clogged with lint, vent flapper not opening...) is suspect.

B. ELECTRICAL
Assuming you have a volt meter and know how to use it properly.

These are the steps that the power and machine have to take to operate properly

1. power is correct (USA 220V across line and 115v to ground/neut) 2 hot lines with potential between them and a neutral and possible a ground
2 Door switch is closed
3 Timer switch closes and ready s power to heating element through centrifugal switch in the motor circuit after the motor is running.
4 the heating element is assumed to be good and have 220v at this point. Checking for voltage at the element will assure all before are ok and at least allowing the heater to work.
5 the heating element is controlled by 1 or more thermostats and a safety thermostat. If either of these switches do not close when the dryer is "cool" they are bad. NOTE some dryers could ahve 3 wire thermostats. These can read closed on one set and open on the other. And this is how they should be if good. But tracing the wire diagram will tell which set is closed and when.
6 if you have power, the timer contacts to the motor and the heater (separate circuits usually)are "closed", the motor runs, the cent switch "closes", the temperature operating thermostats are closed, and the heating element is good you have to have heat.

1 Check for 220V power into the dryer. If not check breakers and turn off and on several time pushing them firmly. If this is ok and 220V present step 1 is done. proceed through all steps above.

If these instructions and explanations are foreign to you I recommend you contact a local service person to check the appliance for you. There are several reasons but mostly safety. DO NOT ASSUME THE POWER IS EVER OFF. Like an unloaded gun is the only one ever in an accident, same applies to electric. The only time anyone gets hurt by electric is when the power is off. If the plug isnt in your hands and you cant see the knives its assumed hot til checked. even with a breaker thrown still check it.

If this helped you in some way please send me a good report. Thank you for using fix ya.

Posted on Nov 01, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

E1 code. water is being pumped out dry and start dryer and 3-5 min code comes back. cleaned everything inside checked all hoses and switch. everything looks fine


Cycle is interrupted and ''E1'' appears in display.

Condensate hose is blocked in some way. Turn off dryer and check hose.
Condensed water not pumped out (WTL 54 condensation models only). Pump failed.

25808741-gtkp3url2ghtdqenstp5bokb-1-0.jpg Dado

Aug 04, 2015 | Bosch Axxis WTL 5410 Electric Dryer

1 Answer

My dryer WTL 5410 electric condensation dryer is cutting on and off.


this is normal operation it turns the drum one direction then the other this is because of the way it condensates

Apr 06, 2014 | Bosch Axxis WTL 5410 Electric Dryer

1 Answer

My dryer is leaking from the bottom. service man said either the tube or the pan is cracked. tube seems ok, so is the pan replaceable or glueable. could there be another reason to look for leak. dryer has...


Open the bottom front panel. Remove the heat exchanger. Take notice to see if theres any water in that compartment. Reach your hand towards the back of that opening to see if there is water pooling back there. If theres water present, then your condensation pump needs to be replaced.
also double check the connection of the drain hose from the dryer to the drain.

Jan 09, 2011 | Bosch Axxis WTL 5410 Electric Dryer

1 Answer

No heat after 2 mins


if it is a condensation dryer try wiping the inside of the dryer in a damp rag with water & vinegar. this will clean any deposits of the sensors.

Nov 08, 2010 | Bosch Axxis WTL 5410 Electric Dryer

2 Answers

WTL 5410 BOSCH AXXIS CONDENSATION ELECTRIC DRYER


the thermostats at the element have to be replaced, they burn out prematurely if the condensor unit is not cleaned on a regular basis.

Feb 02, 2010 | Bosch Axxis WTL 5410 Electric Dryer

1 Answer

Bosch axxis wtl 5410 dryer takes too long to dry.


You should have a cycling thermostat. this is most likely bad or your dryer vent may be clogged. Something is cutting the heat off before it gets hot enough. Both these cause this problem.

Nov 17, 2009 | Bosch Axxis WTL 5410 Electric Dryer

1 Answer

Error Code


open the thing up and locate the service manual. once located it should list what that error means. alternatively call bosch and ask them.

Aug 25, 2009 | Bosch Axxis WTL 5410 Electric Dryer

1 Answer

Bosch Axxis Condensation dryer not working


Try to vacuum clean inside the door contact breaker (female part). If you can remove the dust it should start working again.

Jun 08, 2009 | Bosch Axxis WTL 5400 Dryer

1 Answer

Bosch wtl 5400 elect. condensation dryer


I have a WTL 5400 electric condensation dryer (bosch). All of a sudden one day, it would not turn on. The lights are on, the filters are clean. Please Advise.
Harriet Scannon

Feb 18, 2008 | Bosch Axxis WTL 5400 Dryer

Not finding what you are looking for?
Dryers Logo

Related Topics:

242 people viewed this question

Ask a Question

Usually answered in minutes!

Top Bosch Dryers Experts

yadayada
yadayada

Level 3 Expert

75797 Answers

Lawrence Oravetz

Level 3 Expert

9587 Answers

MightyMikeJr

Level 3 Expert

388 Answers

Are you a Bosch Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...