Question about Reddy Heater-30-55,000 BTU Variable

1 Answer

Ignition I have a reddy heater 35. When I plug it in the fan comes on, fuel dispenses, but then it trips the reset button. Why? When I removed the cover and repeated, I didn't see a spark at the spark plug but then again I don't know if it's supposed to be visible.

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 232 Answers

This is a "probably". The reset button trips because the photocell fails to see a flame in the combustion chamber. That's its job.
Check the ignition device ( transformer, coil). See if 110v going in. If there is no spark coming out, replace it.
Troubleshooting tips

Posted on Jan 12, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya Repairman can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repair professionals here in the US.
click here to Talk to a Repairman (only for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have reddy pro 170 i plug it in , the fan & igniter comes on for 10 to 15 seconds then shuts off ,blew through fuel line and nozzle still same result, i do see fuel mist coming out nozzle ,i dont k


You must make sure the mist is not to close to the igniter . If it is it wont be misty enough to ignite. And make sure its in the path of the mist. If its new return it to the store.

Feb 07, 2015 | Reddy Heater Pro-Tough Kerosene/Diesel...

1 Answer

Reddy heater r100a unit comes on app 1 min then turns off tripping reset button


Hi,


Here are a couple of tips that I wrote that tell you how to troubleshoot a Torpedo or Reddy heater...

Reddy Heater - Troubleshooting Torpedo Heaters





Torpedo Heater Pump Pressure Adjustment


heatman101


]-]-]-]-]-]-]-]-]-]-]-]-]-

Feb 02, 2011 | Reddy Heater-170,000 BTU Kerosene Deluxe

1 Answer

I have a reddy heater 100000 btu model r100a. Everytime I plug it up I have to push the reset button. It comes on only for about 30sec. Then the reset will trip back off and it shut down. What could be...


Does the heater light up before it cuts off. If it does, then you need to first clean the flame sensor. It is a photo type sensor. Remove the top from the heater and the flame sensor is a black rubber boot close to the burner. You can clean it with a soft cloth or a cotton swab and some alcohol. If the heat isn't lighting up before the reset trips, with the top off, start the heater and check the igniter. If it is OK look for fuel spraying from the fuel nozzle. Watch out for the fan while the top is off and the heater is on. If fuel isn't spraying out, check the nozzle for clogs and check the fuel filter. Let me know if you need more help and please rate the answer.
nitensheaterservice@earthlink.net

Jan 15, 2011 | Heating & Cooling

1 Answer

I have reddy htr 35 was running great,just stopped reset breaker lit right up then went out Pulled cover off fan and spark fine reset it lights right up can see the fuel atomizing flame starts...


Check your fuel lines and most models have a fuel filter in line. A few things come to mind one how old is the fuel? Check the screen in the nozzle assembly by removing nozzle it sits directly behind the nozzle, these corrode and affect fuel flow. While you have this tore down clean the fire-eye with windex and terry cloth rag, it may not be seeing the flame. Check the air filter at the back of the heater as well. These are common problems with these heaters.