All-Pro Kerosene Garage Shop Heaters - All Pro PK115T Forced Air Kerosene Space Heater Logo
Posted on Jan 10, 2009
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Motor tries to start but sounds like it is freezing up.

Ready pro 155 motor tries to start and sometimes does but it stops in about 30 seconds. Do I need new motor and where do I get it?

  • wkpoling Jan 16, 2009

    Fan won't kick in

×

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Governor:

An expert whose answer got voted for 20 times.

  • Expert 188 Answers
  • Posted on May 26, 2009
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Governor:

An expert whose answer got voted for 20 times.

Joined: Feb 19, 2009
Answers
188
Questions
0
Helped
88670
Points
345

It sounds like the motor may be going out. I suggest you contact Master Parts at 800-446-1446 or you can find them online at www.masterparts.net they should be able to help you find the part you need. I hope this helps!

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

My whirlpool 6sense washing machine error f15 how to reset

1. Unplug the washer for 1 minute from the electrical outlet.
2. Plug the washer back in and lift and lower the lid 6 times within a 12 second period. You have 30 seconds to start lifting and lowering the lid. ...
3.The motor has now been reset and is ready for you to start a cycle.
0helpful
1answer

How do I get the fault codes up on a Panasonic split air conditioning system CUE24FKR

14.2.2 To Make a Diagnosis1 Timer LED starts to blink and the unit automatically stops the operation.
2 Press the CHECK button on the remote control continuously for 5 seconds.
3 "- -" will be displayed on the remote control display.
Note: Display only for "- -" (No signal transmission, no receiving sound and no Power LED blinking)
4 Press the TIMER ? or ? button on the remote control. The code "H00" (no abnormality) will be displayed
and signal will be transmit to the main unit.
5 Each press of the button (? or ?) will increase error code
number and transmit error code signal to the main unit.
6 When the latest abnormality code on the main unit and
code transmitted from the remote control are matched,
Power LED will light up for 30 seconds and a "beep" sound
(continuously for 4 seconds) will be heard. If no codes are
matched, Power LED will light up for 0.5 seconds and no
sound will be heard.
7 The breakdown diagnosis mode will be canceled unless
pressing the CHECK button continuously for 5 seconds or
operating the unit for 30 seconds.
8 The LED will be off if the unit is turned off or the RESET
button on the main unit is pressed.
Diagnosis
display Abnormality / Protection control Abnormality
Judgement Emergency operation Primary location to verify H00 No abnormality detected - Normal operation H11 Indoor / Outdoor abnormal communica
tion > 1 min after starting
operation Indoor fan operation
only • Internal / external cable connections
• Indoor / Outdoor PCB H14 Indoor intake air temperature sensor
abnormality Continue for 5 sec. - • Intake air temperature sensor (detec
tive or disconnected) H15 Outdoor compressor temperature sensor
abnormality Continue for 5 sec. - • Compressor temperature sensor
(detective or disconnected) H16 Outdoor Current Transformer open cir
cuit - - • Outdoor PCB
• IPM (Power transistor) module H19 Indoor fan motor mechanism locked 7 times occurance
continuously - • Indoor PCB
• Fan motor H23 Indoor heat exchanger temperature sen
sor abnormality Continue for 5 sec. O
(Cooling only) • Heat exchanger temperature sensor
(detective or disconnected) H24 Indoor heat exchanger temperature sen
sor 2 abnormality Continue for 5 sec. - • Heat exchanger temperature sensor
(detective or disconnected) H27 Outdoor intake air temperature sensor
abnormality Continue for 5 sec. O • Outdoor temperature sensor (detec
tive or disconnected) H28 Outdoor heat exchanger temperature
sensor abnormality Continue for 5 sec. O • Outdoor heat exchanger temperature
sensor (detective or disconnected) H30 Outdoor discharge air temperature sen
sor abnormality Continue for 5 sec. - • Outdoor temperature sensor (detec
tive or disconnected) H33 Indoor / Outdoor wrong connection - - • Indoor / Outdoor supply voltage H38 Indoor / Outdoor mismatch (brand code) H50 Ventilation motor abnormality 7 times occurance
continuously - • Indoor PCB
• Ventilation motor H51 Nozzle lock abnormality 2 times occurance
continuously - • Nozzle H52 Limit switch abnormality - - • Indoor PCB H97 Outdoor fan motor mechanism locked 2 times occurance
within 30 minutes - • Indoor PCB
• Fan motor H98 Indoor high pressure protection - - • Air filter dirty
• Air circulation short circuit H99 Indoor heat exchanger anti-freezing pro
tection - - • Insufficient refrigerant
• Air filter dirty F11 Cooling / Heating cycle changeover
abnormality 4 times occurance
within 30 minutes - • 4-way valve
• V-coil F90 PFC control 4 times occurance
within 10 minutes - • Voltage at PFC F91 Refrigerantion cycle abnormality 2 times occurance
within 20 minutes - • No refrigerant
(3-way valve is closed) F93 Compressor rotation failure 4 times occurance
within 20 minutes - • Compressor F95 Cool high pressure protection 4 times occurance
within 20 minutes - • Outdoor refrigerant circuit F96 IPM (power transistor) overheating pro
tection 4 times occurance
within 30 minutes - • Excess refrigerant
• Improper heat radiation
• IPM (Power transistor) F97 Outdoor compressor overheating protec
tion 4 times occurance
within 10 minutes - • Insufficient refrigerant
• Compressor F98 Total running current protection 3 times occurance
within 20 minutes - • Excess refrigerant
• Improper heat radiation F99 Outdoor Direct Current (DC) peak detec
tion 7 times occurance
continuously - • Outdoor PCB
• IPM (Power transistor)
• Compressor

Note:
"O" - Frequency measured and fan speed fixed.
The memory data of error code is erased when the power supply is cut off, or press the Auto Switch until "beep" sound heard following by pressing the "CHECK" button at remote controller.
Although operation forced to stop when abnormality detected, emergency operation is possible for certain errors (refer to Error Codes Table) by using remote controller or Auto Switch at indoor unit. However, the remote controller signal receiving sound is changed from one "beep" to four "beep" sounds.
0helpful
1answer

Landing gear stops for 30 seconds and then starts again under load

I don't work on these, but it sounds like an internal breaker for the motor. Motor old? could be pulling to many amps, gets hot and trips the breaker.
1helpful
1answer

My lg dvd (dv 490) plays dvd then after about 30 minutes,starts to skip a couple seconds which gets worse gradually before its starts to freeze and auto-eject discs.i opened it and noticed the driving...

Sounds like sled motor [the motor that help to spin the disc inside] is faulty. This is purely a mechanical fault. Contact any service technician. The CD drive mechanism should be taken out from the device, for repair. If you wish to get some details; check the site linked here. Pull up older posts. Surf the site with patience. http://electronicshelponline.blogspot.com/
0helpful
2answers

What causes my AC to sometimes stop cooling & can hear a buzzing from the motor?

The blower motor probably needs very badly to be cleaned, lubricated, or replaced, Michael.
0helpful
1answer

Karcher 2.91 model

Sounds like motor is burnt out. Needs replacing.
Jan 18, 2018 • Garden
0helpful
1answer

Blender stopped working

Sounds like the motor burned out.
1helpful
1answer

Pro-form 320x treadmill slows down then motor stops.

Sounds like it is overheating, you have to disassemble the unit and find why it might be overheating
1helpful
1answer

Buzzing

If it is a buzzing noise, it is the Ballast for the lamp.
If it is more of a grinding sound, it is the Color Wheel motor.
Does it go away when you turn off the tv? If so, does it stop abruptly or does the sound tend to get softer (winding down noise)
If the noise stops abruptly it is probably the Ballast.
If the noise takes several seconds and seems to get softer until it stops about 30 sec later then it is the color wheel motor.
Richard Bartlett
Not finding what you are looking for?

139 views

Ask a Question

Usually answered in minutes!

Top All-Pro Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you an All-Pro Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions