Question about Office Equipment & Supplies

1 Answer

Toshiba TLP-T60M fan error

When I start the projector, first the lamp led flashes 3 times.. second the power led turns red, the fan led starts to blink red and in the corner of the screen appears a red fan icon. At this moment all the fans keep spinning faster and faster until the projector snaps back in standby mode.. I've already verified that all the fans are spinning. I have event tried to clean them with some compressed air, but this didn't work. Can anyone help me out?

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

I just had the same problem, you have an idea on this?

Posted on Jul 12, 2016

Ad

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
projdoc
  • 2237 Answers

SOURCE: Projector powers down as soon as LAMP lights up

the ballast/power supply needs replacing.

Posted on Dec 23, 2009

  • 1 Answer

SOURCE: Optoma EP719 lamp does not come on

I have the same problem. The 10V 3200uf capacitor is bulged. Can't find one on the web. Where did you get yours?

Posted on Apr 18, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

What bulb is needed to replace in the projector?


three green lights come on then the standby light goes red and remains on when the projector is plugged in. The lamp and fan do not come on when the power button is pressed instead the lamp light comes on red.

Jul 13, 2010 | Toshiba TLP S30 Multimedia Projector

1 Answer

Tv desn't turn on,power light just flashes ten times and then stops and then again


Error Indication Information
Error No. Error Information ERROR DESCRIPTION LAMP LED OSD LAMP OFF
(Note 3) (Note 4)
POWER LED TEMP LED
Note:
1.When any of the above errors has occurred, the LED will flash as shown above every 5 seconds.
2.When two or more errors have occurred at the same time, the LED will light up or flash as shown above, and then
change to another every 5 seconds in turn.
3.Warning OSD appears when the Air Filter is clogged 90%, accumulated operation time of the Lamp reaches 5000 hours,
or accumulated operation time of the Air Filter reaches 400 hours.
4.LAMP OFF: The LED will flash right after the Lamp goes off.
5.IC2301 is mounted on LCD Main C.B.A. which is included in the Projection Unit.
6.IC6001 is mounted on TV Main C.B.A.
Clogged air filter
more than 90%
15)
16)
17)
18)
1)
2)
3)
4)
5)
6)
7)
11)
8)
9)
10)
12)
13)
14)
- flashes 5 times -
every 5 seconds
IC2301(pin82) detects the clogged air filter, then indicates the
error when the air filter is clogged 90%.
Front Fan stop or
Lamp Fan stop
flashes orange
once every
5 seconds
- -
IC2301(pin12) detects the Front FAN stop or Lamp
FAN stop, then indicates the error when the Front FAN
or Lamp FAN is stopped.
Lamp Cover open
Temperature Sensor
short or open
flashes orange
twice every
5 seconds
flashes orange
3 times every
5 seconds
flashes green for
140 seconds.
flashing red for
60 seconds.
light up red.
flashes once
every 5 seconds
flashes once
every 5 seconds
flashes red for
10 minutes
flashes once
every 5 seconds
-
-
-
-
Abnormal
Temperature
flashes twice
every 5 seconds
flashes twice
every 5 seconds
- -
Request for Lamp
Replacement - - lights up
Power Ballast Error
(abnormal
Lamp voltage)
- -
flashes 3 times
every 5 seconds
Power Ballast Error
(abnormal
temperature)
- -
flashes 4 times
every 5 seconds
Power Ballast Error
(other causes) - -
- -
Request for Filter
Cleaning -
Abnormal Voltage
on 16 V line of
LCD Main C.B.A.
-
flashes twice
every 5 seconds
flashes twice
every 5 seconds
Abnormal Voltage
on 14 V line of
LCD Main C.B.A.
-
flashes 3 times
every 5 seconds
flashes 3 times
every 5 seconds
Abnormal Voltage
on 7 V line of
LCD Main C.B.A.
-
flashes 4 times
every 5 seconds
flashes 4 times
every 5 seconds
IC2301(pin76) detects the Lamp Cover Unit condition
(open or close), then indicates the error when the
Lamp Cover Unit is open.
IC6001(pin85) detects the Duct FAN stop, then
indicates the error when the Duct FAN is stopped.
IC2301(pin74 and 75) detects open or short of the Temperature
Sensor (R2911) on Front Thermistor C.B.A., then indicates the
error when Temperature Sensor is open or shorted.
(The error is not detected for 1 minute after Lamp ON.)
IC2301(pin74 and 75) detects the temperature attached near
the Front FAN by the Temperature Sensor (R2911) on Front
Thermistor C.B.A., then indicates the error when the
temperature becomes more than 43 C (109 F).
(The error is not detected for 1 minute after Lamp ON.)
IC6001(pin86 and 87) detects open or short of the
Temperature Sensor (R2901) on Lamp Thermistor C.B.A.,
then indicates the error when Temperature Sensor is open or
shorted.
(The error is not detected for 4 minutes after Lamp ON.)
IC2301(pin74 and 75) detects the temperature attached near
the Lamp by the Temperature Sensor (R2901) on Lamp
Thermistor C.B.A., then indicates the error when the
temperature becomes more than 60 C (140 F).
(The error is not detected for 4 minutes after Lamp ON.)
IC2301(pin11) detects the error of LCD Power C.B.A.,
then indicates the error when the temperature fuse
(117 C)(243 F) in LCD Power C.B.A. is open.
IC2301(pin11) detects the error of LCD Power C.B.A. and Lamp,
then indicates the error when an inner malfunction of LCD Power
C.B.A. occurs, the Lamp voltage becomes more than 130V or
less than 30V, Lamp current becomes more than 5A, or the Lamp
is cracked.
IC2301(pin11) detects the error of the Lamp, then indicates the
error when the Lamp is short-circuit.
IC2301(pin48) detects +16V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +13V.
IC2301(pin47) detects +14V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +11V.
IC2301(pin45) detects +7V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +5.7V.
IC2301(pin44) detects +3.3V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +2.5V.
flashes 3 times
every 5 seconds
flashes 4 times
every 5 seconds
Abnormal Voltage
on 3.3 V line of
LCD Main C.B.A.
-
-
-
- flashes 5 times
every 5 seconds
Forced cooling
The failure of Lamp
light up
-
Temperature Sensor
short or open
-
-
Abnormal
Temperature
Duct Fan stop -
When accumulated operation time of the the Lamp reaches
5000 hours, OSD (replacing the Lamp) appears on the screen.
Note: The Lamp time is stored in EEPROM (IC2305).
When accumulated operation time of the Air Filter reaches 400
hours, OSD (cleaning the Air Filter) appears on the screen.
Note: The Filter time is stored in EEPROM (IC2305).
During forced cooling, this indication is indicated.
IC2301 (pin11) detects the failure of light up processing of
the Lamp, then the POWER LED is changed as follows.
1) POWER LED flashes green for 140 seconds (while turning on).
2) POWER LED flashes red for 60 seconds (while cooling).
3) POWER LED lights up red (standby).
Note: If the Lamp will not light after attempting turning on the
power 2 or 3 times, the Lamp, the LCD Power C.B.A. or the
LCD Main C.B.A. may be defective.
Error Symptom Problem Possible Solutio

May 30, 2010 | Panasonic Viera TH-50PX80U Plasma TV

1 Answer

Projector shuts off within 30 seconds of power on


is the led lit on the top of the projector? what colors?

green is ok.

red flashing in sequence:
2 times- lamp hours exceed 200 hrs. replace lamp.
3 times- lamp failure. replace lamp.
4 times- fans not working. remove obstruction or replace fan.
5 times- temp too high. clean thoroughly.
solid red- undiagnosed error by projector. possible power supply or ballast.

also make sure the lamp door switch is working.

Aug 07, 2009 | InFocus LP 820 Multimedia Projector

1 Answer

Projector will not project light (Mitsubishi LVP-X80U) LCD Proje.


Hello toma_leonard,

First check your lamp to make sure it is seated properly in the socket.
Then check all of your interlocks (see your manual for locations), these are usually located on any hatches or doors that allow access to the lamp and or fan area. Once you check your interlocks make sure the filter and fan area is clear of dust, (some projectors have air flow sensors), and the recheck the interlocks. Once this is done , If the interlocks are not broken, or the lamp fuse blown, the projector should be working. If not it is the lamp that needs changing.

I know this may be expensive, however these lamps do go bad, as much as we wish they would not.

If you still feel it is not the lamp, have a technician check the voltage levels to the lamp and the levels of the control board circuitry.

I hope this helps,

Thank you,

Shuttle83

Nov 20, 2008 | Mitsubishi LVP-X80U Multimedia Projector

1 Answer

Unit turning off after displaying red pc chip icon


Hi whitiezn

If you say that this unit is very new , it should on all accounts still be under warranty.

Contact your local Toshiba Service Centre and have this problem sorted out on their account - the machine should still be under warranty.

May 05, 2008 | Toshiba TLP-ET1 Multimedia Projector

1 Answer

Toshiba TLP671 - lamp red LED


Hi,

It is problem with temperature. So please check with filter and clean it. Other wise check any of the fans are not functioning properly. So check the same and replace

Nov 14, 2007 | Toshiba TLP 261 Multimedia Projector

1 Answer

I NEED SOLUTION


Hi, Pls check the small Fuse for the supply of the fan. Or you can send it to us to repair.

May 26, 2007 | Toshiba TLP T50MU Multimedia Projector

1 Answer

Blub goes out during use.


Most fans have a sense line to detect the fan is working properly, Possible the sense circuit has failed. The unit should not start if it thinks the fans are not running. Possible thermal problem with the sense circuit, since your unit starts up then stops.

Mar 10, 2007 | Toshiba TLP-ET1 Multimedia Projector

Not finding what you are looking for?
Office Equipment & Supplies Logo

Related Topics:

197 people viewed this question

Ask a Question

Usually answered in minutes!

Top Office Equipment & Supplies Experts

kakima

Level 3 Expert

102366 Answers

jasbo
jasbo

Level 3 Expert

2237 Answers

yadayada
yadayada

Level 3 Expert

76846 Answers

Are you an Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...