Question about Fujitronic Heating & Cooling

Open Question

Fujitronic FA-12SCH Split Air Conditioner and heater

Leakage of freon gas

Posted by Anonymous on

Ad

5 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
jfpogie
  • 104 Answers

SOURCE: Fujitronic FH-776T

yes, it has.

Posted on Jan 24, 2008

Ad
  • 736 Answers

SOURCE: My Fujitronic FA-1310S Air Conditioner makes

if the banging noise only happens when the compressor turns on or off then check the compressor shock mounts .. the compressor is mounted on rubber or spring mounts . if they are out of place or damaged then the compressor will hit the sides as it comes on or turn off .. if the unit was stored upside down or on its side then there is a good chance that the shock mount is out of place ..

Posted on Aug 15, 2010

PabstBR
  • 14 Answers

SOURCE: Can you please tell me

Call the manufacturer. These air conditioners are notoriously problematic.

Posted on Mar 15, 2011

  • 4736 Answers

SOURCE: Hi i have Fujitronic FA-1300

Before assuming it needs to be recharged with refrigerant gas, check the following. As all of these things can affect the cooling,

1. Remove and clean the air intake filter.

2. Check exhaust hoses for obstructions.

3, Exhaust hoses may have to much downward droop. Which doesn't allow the air to exhaust as it
should.

4. check for holes or leaks in the exhaust hoses. Repair or replace the hoses as needed.

5. Check the temperature setting on the controls, as it may be set to high.

If none of the above solves the problem, it may need to be recharged with refrigerant gas. hich is best left to the pros.

I hope this helped you and thanks for choosing FixYa.

Posted on Aug 24, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My Fujitronic FA-1310S Air Conditioner makes banging sounds when it's in cooling mode. How can I fix this? Thanks.


if the banging noise only happens when the compressor turns on or off then check the compressor shock mounts .. the compressor is mounted on rubber or spring mounts . if they are out of place or damaged then the compressor will hit the sides as it comes on or turn off .. if the unit was stored upside down or on its side then there is a good chance that the shock mount is out of place ..

Aug 15, 2010 | Fujitronic FA-1310S Air Conditioner

1 Answer

Only the fan seems to be working, where is nearest repair shop for 64640


mcdevito75 here, Almost any A/C repair shop can handle this A/C unit. Check online for shops in your area. Your A/C unit could need a charge of Freon or the thermostst is out of order and won"t turn on the A/C unit.

Jun 23, 2010 | Fujitronic FA-1300 Air Conditioner

1 Answer

FA 1300 NOT COOLING WELL. IT SEEMS TO KICK ON BUT THEN TURNS OFF AND IS NOT BLOWING COLD AIR


Hi there. If unit just starts to get cold then the compressor shuts off and if the compressor comes back on after 3 to 5 minutes, the system has a freon leak or the compressor is over heating.
If you are technically inclined, search for leaks using soapy water at all tubing connections.
For overheating compressor: Clean the condenser with compressed air or vacuum cleaner. If still overheating, start switch or start capacitor may be bad.
Thanks
Paul

Jul 12, 2009 | Fujitronic FA-1350 Air Conditioner

1 Answer

Fujitronic 1300 ~ compressor does not stay on and not overly cold


sounds like the units compressor is shutting off. this could be caused by being low on freon, or a dirty condensor coil. the condensor coil is where the hor air exits the unit. make sure it is clean, free of lint/dirt. if it is clean, you will need to take it in to a repair shop and have the coolant leak found/repaired and then recharge the unit.

Jun 04, 2009 | Fujitronic FA-1300 Air Conditioner

1 Answer

Exhaust hose replacement parts for Fujitronic Model FA-1300


hello! there,try to website particular service parts mostly on your location where you live,try on google.com and try to type your brand and model then press enter they will give several service center to select that is more conveinient to your place and quality service.and exact price unit feel free to ask any want to purchase.have a good day.and thanks

Mar 30, 2009 | Fujitronic FA-1300 Air Conditioner

1 Answer

Our Fujitronic FA-900 Portable AC is not running cold like it used to.


Try A.B. May they are out of Kansas City but they will travel up to 90 miles I have heard.

Jun 02, 2008 | Whirlwind FH-778 Air Conditioner

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

52 people viewed this question

Ask a Question

Usually answered in minutes!

Top Fujitronic Heating & Cooling Experts