Question about Goodman GMS90703BXA Heater

Open Question

How do you light the pilot on goodman model#cacf024a2a

Posted by Anonymous on

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 82 Answers

SOURCE: Finding Pilot light on Goodman Model caf024a2a

i think the ca # is for the cooling coil unit - the heater should start with gmXXXXX - if your unit is fairly new - the pilot light electronically when thermostat calls for heat the unit will not light if the burner door is open

Posted on Oct 24, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Have a goodman gas pack and we lost power due to winter storm over night so now my unit is running but only cold air coming out


the pilot light runs from a very small gas jet and should not be affected by the power outage
however that is not to say that the jet may have frozen over and become blocked putting out the pilot light
AS the system needs power to drive the fan it is possible that without the fan and safety system working , the main gas supply solenoid would have shut down and that could have affected the pilot light
with the power reinstalled try lighting the pilot light
I would say that there would be a pizo starter on the front of the unit to light the pilot loght

Jan 24, 2016 | Goodman Heating & Cooling

1 Answer

Goodman gas heater model GUE080-4 . pilot lighs , but furnace will not . Electronic pilot lights & stays on for about 1 min, than shuts off seems main gas relay not switching on.need manual


Check roll out switches located around burner compartment.
there is a small square button between the wire terminals press firmly down on it to rest switches. If this solves the problem have the furnace cleaned and checked by a professional HVAC technician.

Bob

Jan 06, 2015 | Goodman Heating & Cooling

1 Answer

Where is the pilot light on a Goodman LP furnace CAPF1824B6CA


I could not find that exact model but I don't think it has a pilot. I think what you have is a faulty igniter.(its a glow plug)

You need to find it-should be on rt side just in front of a burner venturi. Unplug it and check for continuity.

Dec 24, 2014 | Goodman Heating & Cooling

1 Answer

We have a goodman unit that is both a/c and heat model #PGB048125-1 how do I light the pilot?


if you have a newer high efficiency furnace there is no pilot light. They are all electronic ignition

Oct 06, 2014 | Goodman Heating & Cooling

1 Answer

I have a Goodman forced air heating system in my attic that's only about 3 years old and I believe the pilot light went out last night in a storm. My problem is that I can't locate the pilot in the unit...


Marc, look for where the gas line enters the furnace and remove the panel adjacent to it. That should gibe you access to the pilot light. Also, look for a pilot access door, near where the gas line enters the furnace. The gas line will either be 1/2" flexible copper tubing. 1/2" black iron pine or 1/2" vinyl coated flexible stainless steel. Look for the lighting instructions inside or on the side of the unit.

Hope this helps you solve the problem.

Mar 24, 2011 | Goodman Heating & Cooling

1 Answer

I have a 1987 Goodman, (GU150-5 REV S) model gas furnace. The problem I have is keeping the pilot light on. I replace the thermal coupling twice, work for a few days and goes out again. Please tell me what...


If you have a weak pilot flame it could cause this. There is an adjustment screw for the pilot flame under another philips head screw that takes a small flat head screwdriver to adjust. Turning the pilot flame up may help.

Dec 21, 2009 | Goodman GMS90703BXA Heater

1 Answer

Finding Pilot light on Goodman Model caf024a2a. Cannot seem to find the pilot light...The blower works but no heat.


i think the ca # is for the cooling coil unit - the heater should start with gmXXXXX - if your unit is fairly new - the pilot light electronically when thermostat calls for heat the unit will not light if the burner door is open

Oct 24, 2009 | Goodman Heating & Cooling

1 Answer

Goodman ez 1425 blower works but no heat


It has electronic ignition. no pilot light.. it uses a hot surface ignitor to light the burners. this device gets red hot (just like looking down into your electric toaster). this hot cherry red device lights your burners

Feb 21, 2009 | Goodman GMS90703BXA Heater

1 Answer

How do I light the pilot light on my older Goodman heating and air unit?


depending on how old the unit is , you turn the gas valve to pilot setting, hold down the button, light and hold for 1 min.

Oct 27, 2008 | Goodman GMS90703BXA Heater

Not finding what you are looking for?
Goodman GMS90703BXA Heater Logo

Related Topics:

70 people viewed this question

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

paulcarew

Level 3 Expert

2458 Answers

Brandon Berry
Brandon Berry

Level 2 Expert

407 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides