Question about Kitchen Appliances - Others

1 Answer

Blower will not come on

My heater coils heat up but the fan will not come on it is an intertherm e2eb-017ha electric furnace

Posted by on

  • Anonymous Mar 10, 2009

    HAVE TURNED THE FAN ON MANUAL AT THE THERMOSTAT AND WORKS FINE WHICH SEQUENCER CONTROLS THE FAN

×

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 82 Answers

Could be the fan relay is bad. or the run capacitor. if these check good. you may have a bad heat sequencer. hard to tell, if you thave a/c you can turn thermostat fan swith to on and if blower comes on then relay and capacitor should be ok. some units have two or three heat sequencers 1 controls fan and the others control heat strips hopefully this helps good luck

Posted on Jan 04, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Twin Star electric fireplace fan (maybe heater) doesn't work!


I have a twin star electric fireplace insert model #28efo24grs that is missing a remote any suggestions >>>>917-747-4893

Dec 13, 2009 | Kitchen Appliances - Others

1 Answer

I have the following home thermostat Honeywell-YRTH230B1009-Thermostat My husband changed the filter last night and the heat has not been on since. The gas in on and the pilot is lit but still no heat. We...


If your furnace has a filter or fan compartment door, be sure it closed tightly and that the filter is installed correctly - there could be an interlock switch that is preventing the thermostat from operating. Also, if you haven't already turned off the power to the furnace, do that, wait a minute and then turn it back on.

Obviously, make sure the thermostat is on, is set to heat and calling.

Dec 07, 2009 | Kitchen Appliances - Others

1 Answer

Replacing blower motor in furnace w/Fasco brand #D727


Some one missed the wiring diagram. I believe its like this:
L1 = Line 1 = (Hot all are same thing)
Black Hi
Blue Med
Red LO
Now usually the black is for AC and connects to a normally Open (NO) contact on the blower relay.
The heater speed (either red or blue) go the the normally Closed (NC) on the blower relay and on one side of this wire or contact on the relay it goes to the heating blower thermostat on the furnace.
The remaining wire (blue or red) you tape off.
L1 also feeds the Run Capacitor on 1 side and the Brown wire feeds the opposite side

The white wire is Neutral and goes to the neutral on the main line.

If this helps you please rate me accordingly and good luck.








Mar 13, 2009 | Kitchen Appliances - Others

1 Answer

Frigidaire furnace will not run the heat cycle, The furnace calls


It's a flame sensor.It looks like size of regular welding rod and have one wire connected to it.you have to removed and clean with 1000 grid sand paper and put it back on, that's all..

Mar 09, 2009 | Kitchen Appliances - Others

1 Answer

Weatherking Short Cycling


You make a good point about overheating on heat exchanger temp.

Since you don't have to reset anything for it to recycle, then I assume you have one of the newer forced draft furnaces.

There should be leds on the control board inside the furnace compartment that will blink a code to you, telling what the shutdown reason was. Blinks and code should be on a label inside the blower door panel, or inside the control box cover.

Let me know what they are, and I can give you more direction. I am assuming this furnace worked at some point, and no changes have been made (including closing of duct vents).

Jan 26, 2009 | Kitchen Appliances - Others

1 Answer

Furnace flame turning off and on off and on.


sounds like a bad thermocouple.  should be an easy fix.  Thermocouples are cheap and easily installed.  ask for details at any hardware store.

Dec 23, 2008 | Kitchen Appliances - Others

1 Answer

Smell Coming From Intertherm Furnace


It could be several things.

The most alarming being a cracked heat exchanger allowing the exhaust fumes to enter the living space.

Exhaust fumes that contain carbon monoxide.

I HIGHLY RECCOMEND that you purchase carbon monoxide detectors, and/or check the batteries in any you might already have.

Carbon monoxide can be deadly at high concentrations.

It could be burning wires, but would smell like burnt rubber.

It could be mold/mildew but would smell musty like dirty socks.

It could be a build up of dust oil etc on the heat exchanger, but that is usually only smelled when it is started up for the first time in months.

Make sure the filters are clean. Dirty filters can cause overheating of the heat exchanger and sometimes cause smells.

This is one of those times I will recommend you have a professional look at your unit.
Specifically the heat exchanger to look for cracks.

A pro will know where to look, where the usual stress points are etc.

Dec 10, 2008 | Kitchen Appliances - Others

4 Answers

My Ruud Furnace wont stay lit


Hi Bmreid
The problem you describe sounds pretty much like your gas valve is going bad. There is a brand by Honeywell called a Smart Valve which is anything but smart, when the electronics in the valve start going bad the furnace will run great for a day or two and then the next day may not run at all and then an hour later my run and then an hour later may not run again. Very sporadic operating furnace is usually the Honeywell Smart gas valve going bad.

Nov 15, 2008 | Kitchen Appliances - Others

2 Answers

Thermastat and furnace


you should have 24 volts between yellow and white wires at the stat when the stat is set to heat and set as hot as it will go. burners should light first then 3 to 5 minutes later the fan motor should fire up. if burner doesn't light check the wires going into the top of the gas valve see if you have 24 volts arriving there from the stat. if you do then the gasvalve is probably bad. you can bypass the action of the stat by jumping red to white on 90 percent of the stats made and in a few seconds the gas valve should click open gas flow to main burner where pilot ignites it. another easy check you can do is flip stat fan switch to on. fan should come on at once. if not then you have either no high voltage to unit or no low voltage ( as in a bad transformer). if the fan comes on you know you have high volts and low volts...by cover i assume you mean the decorative cover but there second cover with the mercury bulbs and all is still there. if you have only the bare subbase then new stat time. sounds like an old furnace if it has a standing pilot, it should be checked for cracked heat exchanger by a pro with a n electronic carbon monoxide detector. NOT a diy item due to the real danger of co poisoning.

Oct 02, 2008 | Kitchen Appliances - Others

Not finding what you are looking for?
Kitchen Appliances - Others Logo

Related Topics:

259 people viewed this question

Ask a Question

Usually answered in minutes!

Top Kitchen Appliances - Others Experts

kakima

Level 3 Expert

98694 Answers

yadayada
yadayada

Level 3 Expert

63291 Answers

Irene Tulloch

Level 2 Expert

449 Answers

Are you a Kitchen Appliances - Other Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...