Question about Water Heaters

Open Question

Kenmore power miser 9 water heater pilot light won't stay lit

Posted by Anonymous on

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 1 Answer

SOURCE: gas water heater burner wont stay lit

This is a major problem with Kenmore power miser 6, 9, and 12's - we purchased a Power Miser 6 in Nov. 2006 and have had 5 service calls in two years - we are on our 6th call now - Go to http://baheyeldin.com/technology-in-society/mistaken-identity-help-with-kenmore-water-heater.html or Complaintsboard.com and you will see multiple complaints on these models. We had Sears out days after we purchased the water heater, and had parts replaced, then more problems in April 2007 - It worked ok until Nov, 2008 and now it has gone out 3 times. We were told it is lint collecting on the screen that sits under the burner (difficult to get to) - we made a vacume attachment out of PCV pipe (like the one the repairman had) and vacumed the screen when the pilot light wouldn't stay lit - that is what they told us was the problem - but this time, the vacuming isn't working - Ash also builds up on the pilot light burner which has to be removed - you can't replace the thermal coupler without replacing the entire burner unit in this model - In short, if you can get your money back and buy a more reliable model, do it! Sears sold us a maintenance agreement after they had come out 3 times ($290), and still we go for 2-5 days without hot water waiting for them to come out and not fix our water heater. They also told us we should build a platform elevated off the floor to increase oxygen and decrease dust - funny our last model was still working at over 10 years and never had an issue in the same location! Sears installed the water heater, and should have installed it on a platform if that was what was needed. Also, there was no warning about having to vacume the screen (UNDER the heater - very difficult) - when we purchased this model or we wouldn't have bought it - Kenmore water heater repair line now tells you to try scrubbing the screen - but who wants to do this every month??? I can't tell you how inconvenient this has been - Looks like there was a class action suit against LOWE's which included the AO Smith water heaters (which is who built the power miser heaters) - no class action suit yet against Kenmore - This has been a nightmare and at the websites I listed, you will see many more such complaints, and some creative solutions...but I doubt any will work for long. Good luck.

Posted on Jan 14, 2009

  • 3640 Answers

SOURCE: I have a Kenmore Power

check and or replace the thermal coupling. the coupling goes into the main gas control, if the coupling is bad it will shut off gas supply. as a safety measure.

Posted on Mar 09, 2011

SOURCE: pilot light won't stay lit on new water heater

1) Get more air to the water heater and see if problem continues.
2) Read the following pdf-s for things that might apply to your situation.
http://waterheatertimer.org/images/Negative-pressure.jpg
http://waterheatertimer.org/pdf/Attic-Ventilation-and-Pilot-Outage-in-Gas%20Water-Heaters.pdf
http://waterheatertimer.org/pdf/Pilot-light-will-not-stay-lit.pdf

3) Read pdfs above first, and then Add a comment with missing information below, for possible do-it-yourself help.
Does this water heater have a blower?
Is gas valve electronic? Or does gas valve have a dial?
If gas valve is electronic, have you checked outlet with circuit analyzer?
Did pilot light work correctly for a while? If so how long?
Where is water heater located? Hot attic? Closet? Garage? Is area dirty and dusty? Has air intake been cleaned?
What color is pilot flame? Clear blue or yellow-or-orange?
Have you inspected inside of combustion chamber for dripping water?

Posted on Aug 29, 2011

heatman101
  • 43501 Answers

SOURCE: Lowe's hot water heater pilot light will not stay

Hi,

If it is one of the new ones with the fancy gas control and the blinking light... does the light blink?? or not??
If it is blinking then the pilot should stay lit...
If it will not blink then the sensor is bad or not in the right place...

Or... the gas control is bad... this is happening alot...

If it is brand new... take it back...

heatman101

Posted on Sep 05, 2011

  • 5089 Answers

SOURCE: pilot light won' stay lit on water heater

Open following link to identify specific gas control anddownload possible service manuals for that specific product.
http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.htmlIt is possible that air intake is dirty, or combustion partsneed cleaning, or gas control valve is bad, or gas pressure is low.

Posted on May 19, 2012

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Pilot light is lit but won't turn on water heater


What band and type water heater do you have? And about how old is the water heater? Add a comment with more information.

Following general information applies to tank-type residential water heater.
If pilot light is working, then thermocouple is good. Otherwise, if thermocouple was bad, or fallen out of place, then there would be no pilot flame.
Carefully read instructions for lighting water heater located on front of tank ... make sure you have the gas control valve set to ON.
At this point, troubleshoot varies widely depending if your water heater is older and air enters front of heater, or if water heater was made after 2007-9 and has sealed combustion chamber and FV system.'
Troubleshoot also varies widely depending if you have power vent and which type of gas control valve.
Copy following link for troubleshoot by type of gas control valve:
http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html#intellivent
Also post detailed question on pro water heater forum.
http://www.thetankatwaterheaterrescue.com/forums/forum3/

Aug 16, 2012 | Whirlpool Water Heaters

1 Answer

Pilot light won't stay lit on new water heater


1) Get more air to the water heater and see if problem continues.
2) Read the following pdf-s for things that might apply to your situation.
http://waterheatertimer.org/images/Negative-pressure.jpg
http://waterheatertimer.org/pdf/Attic-Ventilation-and-Pilot-Outage-in-Gas%20Water-Heaters.pdf
http://waterheatertimer.org/pdf/Pilot-light-will-not-stay-lit.pdf

3) Read pdfs above first, and then Add a comment with missing information below, for possible do-it-yourself help.
Does this water heater have a blower?
Is gas valve electronic? Or does gas valve have a dial?
If gas valve is electronic, have you checked outlet with circuit analyzer?
Did pilot light work correctly for a while? If so how long?
Where is water heater located? Hot attic? Closet? Garage? Is area dirty and dusty? Has air intake been cleaned?
What color is pilot flame? Clear blue or yellow-or-orange?
Have you inspected inside of combustion chamber for dripping water?

Aug 28, 2011 | American Standard 40 G Natural Gas Water...

1 Answer

I have a Kenmore Power Miser 12 gas water heater that the pilot light keeps going out. The water heater has been in service for 45 months. The pilot light has a blue flame with some orange flame flares...


check and or replace the thermal coupling. the coupling goes into the main gas control, if the coupling is bad it will shut off gas supply. as a safety measure.

Mar 09, 2011 | Water Heaters

1 Answer

Gas water heater burner wont stay lit


This is a major problem with Kenmore power miser 6, 9, and 12's - we purchased a Power Miser 6 in Nov. 2006 and have had 5 service calls in two years - we are on our 6th call now - Go to http://baheyeldin.com/technology-in-society/mistaken-identity-help-with-kenmore-water-heater.html or Complaintsboard.com and you will see multiple complaints on these models. We had Sears out days after we purchased the water heater, and had parts replaced, then more problems in April 2007 - It worked ok until Nov, 2008 and now it has gone out 3 times. We were told it is lint collecting on the screen that sits under the burner (difficult to get to) - we made a vacume attachment out of PCV pipe (like the one the repairman had) and vacumed the screen when the pilot light wouldn't stay lit - that is what they told us was the problem - but this time, the vacuming isn't working - Ash also builds up on the pilot light burner which has to be removed - you can't replace the thermal coupler without replacing the entire burner unit in this model - In short, if you can get your money back and buy a more reliable model, do it! Sears sold us a maintenance agreement after they had come out 3 times ($290), and still we go for 2-5 days without hot water waiting for them to come out and not fix our water heater. They also told us we should build a platform elevated off the floor to increase oxygen and decrease dust - funny our last model was still working at over 10 years and never had an issue in the same location! Sears installed the water heater, and should have installed it on a platform if that was what was needed. Also, there was no warning about having to vacume the screen (UNDER the heater - very difficult) - when we purchased this model or we wouldn't have bought it - Kenmore water heater repair line now tells you to try scrubbing the screen - but who wants to do this every month??? I can't tell you how inconvenient this has been - Looks like there was a class action suit against LOWE's which included the AO Smith water heaters (which is who built the power miser heaters) - no class action suit yet against Kenmore - This has been a nightmare and at the websites I listed, you will see many more such complaints, and some creative solutions...but I doubt any will work for long. Good luck.

Jan 14, 2009 | Water Heaters

1 Answer

Burner wont stay lit


ONE THING COMES TO MIND AS YOU SAY YOU HAVE ALREADY CHANGED T/C IF YOU ARE SURE YOU POSITIONED THE THERMOCOUPLE IN EXACT SAME SPOT ,THE SEDIMENT TRAP GOOD CK AS MOISTURE COULD HAVE GOTTEN INTO LINE THIS WOULD CAUSE LIKE SYMPTOM ALSO A ELEVATED GAS PRESSURE COULD CAUSE THIS ON START UP ALSO THE THERMOCOUPLE WORKS OFF MILLI-AMP TO TELL THE VALVE TO STAY OPEN SO MAKE SURE THE THREADS ARE CLEAN FREE OF MOISTURE AND GOOD AND TIGHT OR IF ALL THIS IS GOOD COULD HAVE BAD VALVE BUT CK THESE FIRST

Jan 14, 2009 | Water Heaters

1 Answer

I have a kenmore "power miser 9 " gas water heater. my basement had about 2-3 inches of standing water on the floor from snow melting ect. now my pilot light wouldnt stay on. so i bought a new...


The problem is the humidity. Get rid of the water and get some ventilation in there plus heat and the pilot light will work once again.

Jan 14, 2009 | Water Heaters

8 Answers

Gas water heater kenmore model pilot will not stay lite


I have the same problem. Water heater operates on a very simple principle. of thermo-mechanical feed-back and response. In my case, I have a Kenmore Power Miser 6, NG heater with an electronic pilot ignition system. The heater is just over one year old and last month (conveniently just after the 12 month service warranty expired) the pilot light started extinguishing on a very regular basis. I find it interesting that the very problem I am experiencing, is happening to other Kenmore owners (victims). The solution can be found in replacing one of two possible components; the pilot assembly or the gas valve manifold. The price of DIY pilot assembly replacement is approx. $60 . The valve component is significantly higher. Water heaters are designed and built to provide years of trouble-free reliable service. This is the first Kenmore product I have owned. From a customer perspective, with regard to product performance, Sears/Kenmore needs to take a strong look at their supplier quality. Oh, by the way, contacting Sears for remedial relief only managed to frustrate and infuriate me. You see, I am in Quality for a world-class aircraft company. I understand what ethical steps are required to satisfy a valued customer. I plan on ripping out the defective unit this weekend and replacing it with a reliable Home depot special. At least with HD, if the heater fails to perform , I can return it. Hey Sears in Chicago, don't come crying to the consumer when you are looking for the trendy "bail out". Signed- "Burned Out" in La Habra, California.

Nov 08, 2008 | Water Heaters

Not finding what you are looking for?
Water Heaters Logo

Related Topics:

1,180 people viewed this question

Ask a Question

Usually answered in minutes!

Top Water Heaters Experts

Donni Steen

Level 3 Expert

659 Answers

Brad Brown

Level 3 Expert

15478 Answers

Gil Shultz

Level 3 Expert

3368 Answers

Are you a Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...