Question about Heating & Cooling

1 Answer

I would like to add a thermostat unit to my insta flame FS-30 propane stove how do I do it? So I can have my unit running when I am not their. Keep in mind we are off the grid and don't have powe

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Greenhorn:

    A rookie expert who has answered 20 questions on their first day.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 58 Answers

Mercury Switch Thermostat still need some power.

http://www.thermon.com/US/mechctrlmonitor.aspx
here is some
Mechanical Thermostats

Posted on Nov 01, 2012

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 96 Answers

SOURCE: flame going out!

Take the flame sensor out and clean with fine sand paper or emory cloth

Posted on Dec 09, 2008

Therinnaiguy
  • 1420 Answers

SOURCE: unit runs normal but when

Bad blower relay on circuit board. You can live with it or replace the board. Blower relay is not available as a separate part.

Posted on Dec 20, 2009

  • 188 Answers

SOURCE: 150,000 BTU propane Reddy Heater shuts off after ignition

Is there a frost line on your LP tank, if so you may need to replace the tank with a larger tank or refill your tank. This can happen if the tank your using is too low or too small (use 100 lb tank or greater). If there is no frost line it may be an issue with the thermocouple. The manufacturer offers a service manual and owner's manuals on there site. This should assist you... www.desatech.com Thank you

Posted on Jan 28, 2010

  • 74 Answers

SOURCE: flame wont stay on, runs for about 5-10 secs and

usually the thermocouple wears out. Make sure the thermocouple is in the flame, if it is, and it still wont stay lit I would change that first.

Posted on Feb 28, 2010

  • 472 Answers

SOURCE: My gas furnace fires but then cuts out. There is a

HAD A similiar problem last week with a customer who had just installed a pool and running off of propane tank for gouse as well... he let tank go empty and started having problems ..what we ended up finding is that not only was his regulator on tank bad he needed a additional regulator to regulate the different psi pressure to the appliances... get them to check your regulator out

Posted on Jan 26, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I bought an Insta Flame model FSDV 30 direct vent wall furnace, need a natural gas conversion kit. It currently is set up for propane and could use some help in finding the parts and installing them.


There is a ban on that particular furnace as they can explode!

You won't find parts or anyone that will work on it.

[PDF]TSSA Bans Series of Insta-Flame and Northern Flame Fireplaces www.dunnheating.com/.../TSSA%20Bans%20Series%20of%20Insta_Flame%20and%...
  1. Cached
  2. Similar
Oct 23, 2012 - (TSSA) has banned a series of natural gas and propane-fired direct vent ... 'FSDV22' or 'FSDV30' or 'FSDV32' in the model name or number.

TSSA Bans Series of Insta-Flame and Northern Flame ... - CNW Group

www.newswire.ca/.../tssa-bans-series-of-insta-flame-and-northern-flame-fireplaces-51...
  1. Cached
  2. Similar
Oct 23, 2012 - All Insta-Flame and Northern Flame natural gas or propane-fired direct vent freestanding fireplaces with 'FSDV22' or 'FSDV30' or 'FSDV32' in ...

[PDF]Fuels Safety Program DIRECTOR'S ORDER - TSSA

https://www.tssa.org/corplibrary/ArticleFile.asp?Instance=136&ID...
  1. Cached
  2. Similar
Mar 25, 2016 - Natural Gas Fired Direct Vent Free Standing Fireplace - Model ... Insta-flame or Northern Flame: Models FSDV22, FSDV30, FSDV32, D222.

Majestic Fireplace - - Recalls & alerts - Healthy Canadians Website

www.healthycanadians.gc.ca/recall-alert-rappel-avis/hc-sc/2012/15058a-eng.php
  1. Cached
  2. Similar
Nov 9, 2012 - Natural gas and propane-fired direct vent free-standing fireplaces ... Insta-flame or Northern Flame (Models FSDV22, FSDV30 and FSDV32, ...

TSSA Safety Order Ban of Majestic FSDV22, FSDV30 and FSDV32

www.fireplacegroup.ca/tssa-safety-order-ban-of-majestic-fsdv22-fsdv30-and-fsdv32/
  1. Cached
  2. Similar
Dec 21, 2012 - TSSA Safety Order Ban of Majestic FSDV22, FSDV30 and FSDV32 ... CFM Inc. (Majestic Fireplace) and bear the trade names Insta-Flame or Northern Flame ... (a) Natural Gas Fired Direct Vent Free Standing Fireplace - Model FSDV22, FSDV30 ... -Stove shipped as natural gas; LP Conversion Kit included

http://www.healthycanadians.gc.ca/recall-alert-rappel-avis/hc-sc/2012/15058a-eng.php

Dec 11, 2016 | Kitchen Ranges

1 Answer

How do I know if my Caloric Heritage gas range is propane or natural gas? It is a used stove that was given to us


Stoves are usually sent from the factory set for natural gas. they have to be converted to Propane. If it is set for propane the flame will be very low on natural gas. If set for natural gas on propane the flame will be very large. The orifices for natural gas are much larger than propane orifices. and the regulator is converted acordingly.

Nov 10, 2014 | Kitchen Ranges

1 Answer

Why won't the broiler flame on my kenmore gas stove adjust?


you may have to replace the orifice with a smaller one. Follow the gas tube from the broiler to see if it runs thru the same regulator. Some units use a pressure regulated gas valve.

Aug 22, 2014 | Kitchen Ranges

1 Answer

Gas pressure is very low and quickly subsides then flame goes out.


Try the following:

Reinstall propane with fresh full propane canister. If problem persists then check tubing in stove for blockages. Make sure you open valve all the way for lighting.

If this doesn't work you may have a defective unit and need to replace it or send it for repair.

Thomas

Nov 03, 2013 | Coleman 2 Burner Propane Stove 5430E700

1 Answer

My gas furnace fires but then cuts out. There is a similar post on here about this but my problem is a little diiferent. The unit kicks on, fires then shuts right down. The blower comes on and stays on....


HAD A similiar problem last week with a customer who had just installed a pool and running off of propane tank for gouse as well... he let tank go empty and started having problems ..what we ended up finding is that not only was his regulator on tank bad he needed a additional regulator to regulate the different psi pressure to the appliances... get them to check your regulator out

Jan 24, 2011 | Goodman Heating & Cooling

1 Answer

Flame going low on range cook-top


Check your gas supply is not running too low and then check for leaks, Let me know if this helps.

Jan 02, 2010 | Tappan TGF320 Gas Kitchen Range

1 Answer

Flame is too high even when on low


The pressure regulator and the orifice for the burners has got to be changed to run LP

Aug 14, 2009 | Whirlpool SF367 Gas Kitchen Range

2 Answers

Dometic/Duotherm propane furnace won't fire up


If this unit has a spark ignition you may just need to clean the flame sensor. It is a metal rod protruding in the path of the flame.

Feb 10, 2009 | Dometic Rooftop RV Air Conditioner

1 Answer

Won't stay running


is this kerosene or propane. if kerosene, two types of ignition is used.  a spark plug or a hot surface ignitor.  the kero unit uses a cad cell flame detector, the propane unit uses a millivolt generator.
the kero unit uses an air pump that comes off the backside of the fan motor - this airline goes to the nozzle and acts like a siphon for fuel.  there is no air pump for the propane heater. the fan just accelerates airflow through the combustion chamber.  the cad cell of the kero unit sees the flame and varies its resistance.  it is sensitive to the infrared generated by the flame and feeds this signal to the lockout relay. no flame after a few seconds, opens and locks out the unit.  the propane unit uses a millivolt generator.  it is a copper cappillary tube that has two spade connectors on it. the spade connectors are connected to a high limit mounted on the backside of the combustion chamber.  under normal conditions the hi limit is closed and completes the electrical circuit to the main valve. the millivolt generator is electrically connected to the pilot/main valve electromagnet inside. with a flame detect signal the electromagnet is energized and holds the main valve slug open allowing the propane to feed to its nozzle in the chamber. as long as there is a flame the valve stays open. no flame, no signal and the unit releases the valve pellet and closes.  you can test the hi limit by jumping out the two spade connectors and see if the unit starts and stays running.da8a32c.jpg

Apr 06, 2007 | Reddy Heater R70 Portable Forced Air Space...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

219 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

2597 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...