Question about Omron Healthcare Health & Beauty

Open Question

Need manual for omron c21 nebulizer - Omron Healthcare Health & Beauty

Posted by Anonymous on

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

renx
  • 71 Answers

SOURCE: Omron nebulizer will not mist. All tubing is intact. What to do?

You'll read a lot about making sure that the filter is clean and that the medicine cup is cleaned and that hard water can effect the operation of the nebulizer. However, the problem is most likely in the pump. Even though the pump is running, it is not pushing enough air into the medicine cup. You may even feel air coming out of the tube. When unrestricted, the air will come out, but, once restricted by the medicine cup, the air may not be fast enough to nebulize the liquid. If you want to confirm this, take the tube and hold it to the end of a bike pump, if, while pumpung, you successfully see mist, then you know for sure.

Fixing the pump is not too difficult. Over time, the chamber where the air is compressed becomes dry and, just like a dry bike pump, the air escapes from the chamber due to poor seals. The pump is pretty simple. Make sure it is unplugged from power and remove the screws holding the housing together. Inside you will see the motor, a fan, a power switch and the intake and outtake tubes. Follow the outtake tube to the pump. The junction where the tubes meet the pump is the location of the air chamber. You may need to remove the screws that secure the tubes to the chamber. Once apart, take some grease and lightly coat all of the interior surfaces of the chamber. When finished, reassemble and you're good to go!

Posted on Apr 21, 2009

renx
  • 71 Answers

SOURCE: Vapour does not come out of Omron NEC28 nebulizer

You'll read a lot about making sure that the filter is clean and that the medicine cup is cleaned and that hard water can effect the operation of the nebulizer. However, the problem is most likely in the pump. Even though the pump is running, it is not pushing enough air into the medicine cup. You may even feel air coming out of the tube. When unrestricted, the air will come out, but, once restricted by the medicine cup, the air may not be fast enough to nebulize the liquid. If you want to confirm this, take the tube and hold it to the end of a bike pump, if, while pumpung, you successfully see mist, then you know for sure.

Fixing the pump is not too difficult. Over time, the chamber where the air is compressed becomes dry and, just like a dry bike pump, the air escapes from the chamber due to poor seals. The pump is pretty simple. Make sure it is unplugged from power and remove the screws holding the housing together. Inside you will see the motor, a fan, a power switch and the intake and outtake tubes. Follow the outtake tube to the pump. The junction where the tubes meet the pump is the location of the air chamber. You may need to remove the screws that secure the tubes to the chamber. Once apart, take some grease and lightly coat all of the interior surfaces of the chamber. When finished, reassemble and you're good to go!

Posted on Apr 21, 2009

  • 31 Answers

SOURCE: can pulmicort nebules be used in the Omron Comp

Yes. But not in an ultra sonic nebulizer.

Posted on Jun 26, 2010

  • 7 Answers

SOURCE: The baffle part of our

You can use pretty much any nebulizer kit (try the brand salter, item#8900), this is a universal kit and fits most nebs, I have not seen Omron offer the baffle piece seperate of a new kit (or new neb). Your local pharmacy (Walgreens in my area) sells the kits, or check with the provider that gave you the unit.

Posted on Jan 27, 2011

alpug
  • 1961 Answers

SOURCE: My Omron Ne U22V Microair Vibrating Mesh Nebulizer

this means that the replacement battery is underrated .the power is not enough to turn the unit.make sure to use replacement battery with the same current rating to the original battery take a look at the original battery the current rating is printed as Milli ampere and voltage.buy a replacement battery with the same rating with the original..

Posted on Jul 05, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Lost adapter for nebulizer, can you use any AC adapter that uses the same output neeeded?


Hi...I just looked on Ebay and there are some AC and DC chargers for your nebulizer on there.

Dec 13, 2012 | Omron Healthcare Inc Omron AC Adapter for...

2 Answers

Omron vibrating mesh nebulizer quit working


You must be having trouble with the battery. Also please keep the nebulizer properly cleaned as instructed on the pack. Check the connection properly or replace the batteries if needed. Also check out for more information about Omron Nebulizer on the web. It would help you a lot.

Aug 06, 2012 | Omron Health & Beauty

2 Answers

My ne u22v is not making mist


You should check if the battery is working fine. I don;t think Omron U2 nebulizer can have any other problem as it works really good for me. Also it is important to clean the Nebulizer properly and please check out the manual for more info. which you would have received while purchasing the Nebulizer.

Aug 06, 2012 | Omron Ne U22V Microair Vibrating Mesh...

1 Answer

Reconstruction of nebulizer


I don't think there's C-08, Here's a manual for C-28 Nebulizer. This might help you a bit. http://www.omronhealthcare.com/wp-content/uploads/ne-c28_im1.pdf

Jul 10, 2012 | Omron Compair Compressor Nebulizer System...

1 Answer

The baffle part of our Omron Nebulizer is broken could you please tell if we can get the same from somewhere in market or if the complete Nebulizer kit is available??


You can use pretty much any nebulizer kit (try the brand salter, item#8900), this is a universal kit and fits most nebs, I have not seen Omron offer the baffle piece seperate of a new kit (or new neb). Your local pharmacy (Walgreens in my area) sells the kits, or check with the provider that gave you the unit.

Jan 24, 2011 | Omron Health & Beauty

1 Answer

My comp air elite compressor nebulizer system NE-C21 works fine when plugged in.........I have had the battery charging since this morning and put on the unit and there is no sound...the babbery is NE-C21...


I think it is a factory defect. I have the same unit bought the battery from a reputable distributor (same one I bought the machine from ) machine worked fine using the home and car charger ( which is how I usually used it). I only used the battery for about 5 -7 hours total . By the time I realized the battery was of no use, it was pass the date of return. $125.00 wasted ( the cost of the battery )

Sep 09, 2010 | Omron Compair Elite Battery and Charging...

3 Answers

Omron nebulizer will not mist. All tubing is intact. What to do?


You'll read a lot about making sure that the filter is clean and that the medicine cup is cleaned and that hard water can effect the operation of the nebulizer. However, the problem is most likely in the pump. Even though the pump is running, it is not pushing enough air into the medicine cup. You may even feel air coming out of the tube. When unrestricted, the air will come out, but, once restricted by the medicine cup, the air may not be fast enough to nebulize the liquid. If you want to confirm this, take the tube and hold it to the end of a bike pump, if, while pumpung, you successfully see mist, then you know for sure.

Fixing the pump is not too difficult. Over time, the chamber where the air is compressed becomes dry and, just like a dry bike pump, the air escapes from the chamber due to poor seals. The pump is pretty simple. Make sure it is unplugged from power and remove the screws holding the housing together. Inside you will see the motor, a fan, a power switch and the intake and outtake tubes. Follow the outtake tube to the pump. The junction where the tubes meet the pump is the location of the air chamber. You may need to remove the screws that secure the tubes to the chamber. Once apart, take some grease and lightly coat all of the interior surfaces of the chamber. When finished, reassemble and you're good to go!

Mar 23, 2009 | Omron Healthcare Omron NE-C25 COMP-Air...

Not finding what you are looking for?
Health & Beauty Logo

Related Topics:

34 people viewed this question

Ask a Question

Usually answered in minutes!

Top Omron Healthcare Health & Beauty Experts

Robin Hill
Robin Hill

Level 3 Expert

1263 Answers

wcdoc1953
wcdoc1953

Level 2 Expert

278 Answers

yadayada
yadayada

Level 3 Expert

75822 Answers

Are you an Omron Healthcare Health and Beauty Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...