Question about Power Generators

2 Answers

No power Carl, This generator came to me after I found the owner an AVR board. They still couldn't get it to produce power after installing it. I advised them to "Flash the field". Still nothing. Brought it to me. AVR board has an obvious burn on it, but I want to know what caused it before I get another board. I work on Generac and any Briggs Power Product. I have no info on these Colemans. Need a wiring schematic so I can test the stator and rotor for problems. Generator has less than 10 hours on it.Even with bad AVR board, still produces 190 volts ac on one set of power wires. Nothing on the other set. I can't tell which wire is which. Jerry Hoffman 303-910-9411 chiralysis@evcohs.com

Posted by on

2 Answers

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

Check out this video. It will show you how to test the AVR and alternator.
http://generatorguru.com/help-me-fix-my-generator-repair-advice/
From there it will be much simpler to fix as it will point you to the part that is failing. Also you can call us if you need further advice. We are always happy to help.
Generator Guru

Posted on Sep 14, 2013

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 169 Answers

Hi Jerry,
The power wires are usually numbered 11 & 22 (one winding) and 33 & 44 (the other winding) Because it makes 190VAC on one side only I'd suspect that the AVR output got burned trying to force the rotor to make voltage it couldn't sense. If I remember correctly the AVR will have wires 11 & 22 connected to it as the sense input, so if that side of the stator is open or shorted, or if the sense wires got broken the AVR will be mased out trying to get the right voltage.

You don't specify which model this is but some of the manuals are available here.

Regards,
Carl

Posted on Jan 07, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I need a rectifier or avr for generac 3500 xl genarator


Ebay and various places including the maker..

  • VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR-GENERATORS ... www.ebay.com/sch/sis.html?_nkw=VOLTAGE-REGULATOR-3000-3500-WATT... VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR ... New listing 3500 Watt Generator AVR Automatic ... 3500W Generator AVR Automatic Voltage Rectifier ...
  • 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator ... https://sites.google.com/site/kltthtyz0i04cd/3500-w-3500-watt... Generac Guardian 22kW Standby Generator NG ... Previously Pay for Shop 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator Rectifier 3.5KW Generator AVR ...
  • How to test your Electricity Generator's AVR, Brushes and ... www.youtube.com/watch?v=tC_LrrZcx38
    • BY GENERATOR GURU
    • 9 MIN
    • 454K VIEWS
    2011-10-21 · Video embedded · When your electricity Generator stops producing power, ... How to test your Electricity Generator's AVR, ... Generac iQ: The Quietest Generator ...
  • Generac Power Systems - Home www.generac.com Generac manufactures the widest range of power products in the marketplace including portable, RV, residential, commercial and industrial generators.
  • Generac Guardian Generator Voltage Regulator Rectifier ... www.ebay.com/sch/sis.html?_nkw=Generac+Guardian+Generator+Voltage... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator ...
  • Automatic Voltage Regulator (AVR) for Generators portable.generatorguide.net/avr.html How automatic voltage regulator (AVR) works in portable generators: ... here you can see a reverse engineered Generac regulator that uses SCRs and UJT.
  • Diagnosing A Generator That Has No Power Output. - YouTube Youtube
    • BY THEDIYGUYDOTNET
    • 3 MIN
    • 150K VIEWS
    2012-11-12 · Video embedded · Diagnosing A Generator That Has No Power Output. ... How to test your Electricity Generator's AVR, ... Generac Portable Generator ...
  • GENERATOR Diagram & Parts List for Model 3500xl Generac ... www.searspartsdirect.com > ... > 3500XL GENERAC Generator-Parts GENERATOR Diagram and Parts List for GENERAC Generator-Parts model # 3500XL ... Generator rectifier Part #: ... Generator voltage regulator Part #: ...


  • Jun 28, 2016 | Generac Power Generators

    1 Answer

    My coleman 5000 generator with a briggs & stratton engine started just fine after years of colecting dust in the shop. After we let the generator warm up we applied a load and found out there is no...


    Without knowing the exact model generator you have, it may not even have an automatic voltage regulator (AVR). Colemans were known for losing what is known as "residual magnetism", especially when sitting for long periods of time without use. This residual magnetism is necessary for exciting the field to produce electricity. Here is what you can try: Plug a 110v drill into one of the 110 outlets. While the engine/generator is running, with an open hand (not fingers wrapped around it) spin the chuck while holding the drill trigger in the run position. Many times this small amount of current that will be produced by spinning the drill motor will restore the residual magnetism and excite the field. Keep in mind that if this works, the drill motor will begin to spin immediately since it is plugged into the outlet. Hope this helps.

    Feb 24, 2011 | Coleman Powermate Powermate 5000W...

    1 Answer

    Runs good circuit breakers good,no power


    I had the same problem with the same generator. It has served me well for 10 years but recently broke. Apparently it the AVR circuit board. A common problem with older generators. The bad news is it's expensive. After much searching I found it Mitsubishi part # KYC031002210. Price, $350.00! Good luck.

    Dec 11, 2009 | NEC Mitsubishi MGE 2900 Generator- Voltage...

    1 Answer

    AVR board is burnt out


    AVR burn out is the most popular problem with electricity supplyment....
    replace the AVR...if it burnt out shortly after words..then u have a problem with the rpm of the engine...if not..then its just a AVR burnout..
    don't hesitate to write to me for further information:
    sal_kh_sab@yahoo.com

    Sep 27, 2009 | Coleman Powermate Powermate 5000W...

    1 Answer

    Coleman 6250 ,no power generated


    check your AVR card...if the brushes are fine...

    Aug 16, 2009 | Coleman Powermate Premium Plus 6250W...

    1 Answer

    Gererator stops producing power


    This sounds like a "flying open" in the rotor. Over time a small part of the wire that winds around the rotor has gotten cracked just enough to open up when it's warm and being pulled on by the force of the rotor spinning. To test this further, take the wires off the brushes and connect an ohm meter across them then run the generator, if you see the ohm meter indicate an open circuit you've found the problem. This can be repaired but it means removing the rotor and finding the weak spot in the winding. You could replace the rotor for a couple of hundred dollars or get a new generator.

    Regards,
    Carl

    Feb 23, 2009 | Coleman Powermate Premium Plus 6250W...

    1 Answer

    I have a coleman 5000 that runs fine but it stops producing power after it runs for a couple of minutes.


    Same answer as the last time you asked, likely a flying open. If the rotor test proves that your rotor isn't opening up, test the capacitor on brushless models or the voltage regulator board on brush generators.
    Regards,
    Carl

    Feb 23, 2009 | Coleman Powermate Premium Plus 6250W...

    2 Answers

    20KW Guardian Generac does not produce 12 volts to run engine


    The problem is that the printed circuit board inside the generator draws a little current from the battery even when the generator is not running. Over the course of a few days this can make the battery weak enough to be unable to get recharged by the built in running charger which results in not enough power to run the electronic governor on the generator. Usually the spark plugs will work even with a fairly low battery.

    Most of the Generac generators come with a built in trickle charger that runs off of the transfer switch load terminals. If your built in charger isn't doing the job it's either broken or you have the wrong sort of battery installed in the generator.

    Regards,
    Carl

    Jan 11, 2009 | Power Generators

    Not finding what you are looking for?
    Power Generators Logo

    Related Topics:

    381 people viewed this question

    Ask a Question

    Usually answered in minutes!

    Top Power Generators Experts

    John Trevino

    Level 3 Expert

    1378 Answers

    EugenesDIYDen
    EugenesDIYDen

    Level 3 Expert

    479 Answers

    Donald DCruz
    Donald DCruz

    Level 3 Expert

    17129 Answers

    Are you a Power Generator Expert? Answer questions, earn points and help others

    Answer questions

    Manuals & User Guides