Question about Coleman Powermate Subaru 5000W Portable Generator

1 Answer

How do i disconnect the low oil sensor

With the Sandy bearing down on the east coast i need to get my Coleman PM0435001 generator running. It wont start. How can i disconnect the low oil sensor? By the way there is plenty of oil - many thanks! Mark

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Prodigy:

    An expert who has answered 500 questions.

  • Coleman Expert
  • 573 Answers

Some oil sensors will stop the generator from running if unplugged, IE they close the circuit on oil pressure, some close the circuit on oil pressure. I wouldn't recommend but with it running just take the single wire off the sensor, if it stops immediately then it requires the signal grounded to run. Some ground on low oil.

Posted on Nov 15, 2013

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017

Ad

SOURCE: oil type and capacity

Use 10/30 weight oil fill till : " if it has a "dipstick" fill to middle of hash marks" if not, There in the hole for the oil filler cap their is a knotch cut out of the theads for that cap. fill to just below the top of that knotch . drain plug on bottom of crankcase

Posted on Sep 01, 2008

SOURCE: coleman 5500 (MZ300)

If the oil is dirty, it will not pump properly. I recently had this problem, once I changed the oil it was good to go.

Posted on Sep 02, 2008

CarlGehrke
  • 169 Answers

SOURCE: What type of oil for a Coleman 5000 Generator?

You need a quart of regular old SAE 5W30 motor oil with detergent.
The engines on these generators are more or less the same as a lawn mower.
Don't forget to service/change the air cleaner when you change the oil, that should keep your generator producing full power.

Regards,
Carl

Posted on Dec 15, 2008

  • 1 Answer

SOURCE: I have a UST GG5500 Generator practically new will not start

I had the same problem with this generator. I tried all of the usual suspects: fuel level; fuel valve; oil level; air clearner, spark pluge etc. The problem is a "tilt" saftey shutoff --I was using the generator on a pea gravel patio and it settled about 2" out of level... The tilt switch is not mentioned in the manual and it apparently does not reset itself once the generator is leveled.

To reset the switch, ensure that the generator is on level and stable ground, the find yellow wire that goes from a switch on the front side of the engine crankcase to the bundled wiring harness behind the panel. Disconnect the yellow wire at the in-line quick-connect coupler, which can be found by following the yellow wire from the switch on the crankcase toward the wiring harness. Once disconnected, start the generator as normal. The engine should start right up. Let the engine run for a minute, then kill the engine and reconnect the yellow tilt-switch wire and try to restart. I had to go through the disconnect-start-reconnect process twice before it reset, so if it wont restart after you reconnect the wire, disconnect it agian and let the engine run a few more minutes.

I hope this sovles your problem.

Posted on Mar 05, 2009

protek480
  • 1723 Answers

SOURCE: My coleman powermate generator will start but will not generate.

The voltage regulator controls the output. You will need to check that first.

Posted on Aug 01, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Coleman PM0435001


When you cleaned the carb did you clean the fuel jet that is in the carb. Quite often it is the screw that holds the fuel cup on the carb. If that little hole has any dirt in it the engine will not start or run.

Mar 08, 2018 | Coleman Garden

1 Answer

Coleman PM0435001, won't start


You checked there is a spark I presume.

Mar 08, 2018 | Coleman Garden

1 Answer

My 3500 watt Coleman genset with a Briggs and S engine starts fine but shuts down after 10 mins to 1 hr of running. then starts again on the first pull??


Most likely oil sending unit or fuel vacuum lock. Easy to check. Run with gas cap loose to allow air into tank. if it still shuts down, temporarily disconnect oil sensor. If the oil sensor is giving false reading and shutting down the engine, just leave disconnected, however, be diligent about checking oil level. Good luck.

Feb 02, 2016 | Coleman Electrical Supplies

1 Answer

Power mate 6250. Starts and runs fine until I take the choke off, then why does it die?


Coleman engine starts runs short time quits Power ... - Fixya

www.fixya.com > ... > Power Generators
Coleman Powermate 6250 only runs with choke closed/air restricted ...starts and runswith full choke, but dies with choke off. ... some gas in the cilinder through the plug hole)and start the engine until it runs constantly. bestregards ... Ad ... I use a fuel stabilizer ... ...engine runs fine but produces no power at all to the breaker.

Coleman car starts but will not stay running Power ... - Fixya

www.fixya.com > ... > Power Generators
Question about Powermate Premium Plus 6250W Portable Generator ... squirt a little gas in the carb it will run until gas is gone doesnt seem to get gas from . ... ...starts and runs fine for about a minute, then dies as though starved for fuel. ... load up on fullchoke and stay running around 3/4 choke HI, Turn off the gas and take ...

Generator runs then shuts off - YouTube

? 8:17
https://www.youtube.com/watch?v=6esHkPyygWw
Sep 6, 2011 - Uploaded by mainblind
How to make Generac generator run bypassing the low oil sensor and ... Remove all; Disconnect .... My ...

Jan 13, 2016 | Coleman Electrical Supplies

1 Answer

I have a Coleman Powermate pm0545007 generator with a B&S OHV model 200000 engine. It has always run fine, but after running it for about 3 hours last week, I can't start it. It has no spark. I...


there should not be pinched wires...

if you mean "how do I bypass the low oil SENSOR" then the answer is to just disconnect it and tape up the end or snip it off in a location where it won't ground out...the way these engines kill the spark is by grounding the cdi coil wire...so fix that pinched wire and youre probably good to go...dont disconnect the low oil sensor unless its causing trouble....having low oil protection is good and might save you from blowing an engine

Jul 02, 2010 | Coleman Powermate Premium Plus 6250W...

1 Answer

Motor runs but have no power coming out of outlets of mygenerator


1 - Check the circuit breakers on the front of the panel where the outlets are located.
2 - Make sure the black molex plug on the back of the panel where the outlets are located is plugged in securely.
3 - Carefully take the plastic endbell off the generator ( you'll need a 7/16 inch wrench and socket) and look for broken or missing brushes, broken wires, etc.
4 - If you're not up for #3 take it to a good repair shop. :-)

Nov 13, 2008 | Coleman Powermate Premium Plus 6250W...

Not finding what you are looking for?
Coleman Powermate Subaru 5000W Portable Generator Logo

825 people viewed this question

Ask a Question

Usually answered in minutes!

Top Coleman Electrical Supplies Experts

John Trevino

Level 3 Expert

1388 Answers

Craig Butler
Craig Butler

Level 3 Expert

1723 Answers

Phil Walker
Phil Walker

Level 3 Expert

608 Answers

Are you a Coleman Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...