JVM1870SK03 ge microwave fan turn on whenevr we close the door

The plate does not rotate

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • GE Master
  • 9,047 Answers

We see (and repair) this a lot. The problem is a shorted main relay on the control circuit board, which we regularly repair with our $39.95 service.

At our Web site, you can get details of our service, plus we have a video available showing how to remove a typical over the range control panel assembly in under 5 minutes.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
JVM1870SK03 ge microwave fan turn on whenevr we cl - 10_26_2012_5_00_00_pm.jpg

Posted on Oct 26, 2012

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

MicrowaveSvc
  • 9047 Answers

SOURCE: GE Profile Spacemaker 2.0 Microwave

If it goes dead or blows the breaker or GFI when you plug it in or open or close the door, then there's a problem with a door switch or door switch mount.

Even though a door switch clicks, it may still be bad inside. Its continuity must be checked.

Door switch or mount trouble can be caused by slamming the door or by opening the door while it's cooking without hitting the Stop pad first.

There are plastic mounts inside the microwave which hold the door switches and onto which the door latches lock when you close the door.

The screws on these mounts may be loose. If they get too loose, the switches will not be activated properly.

Sometimes it's a broken tab on the switch holder, allowing the switch to rotate just out of position. Other times, it's a broken tab on the switch holder, allowing the switch to rotate just out of position. This tab can be hard to see, since it is under the bottom edge of the switch.

If you or someone you know decide to look into it, we have critical information on safety, disassembly and door switches at our site, and our link is at our listing here on FixYa:.

You can find helpful exploded view diagrams and order parts by entering your full model number here.

There may also be a "mini-manual" hidden inside the unit behind the control panel or hidden on the left side behind the grille, which is very helpful when troubleshooting & testing.

We're happy to help you and we'd appreciate your thoughtful rating of our answer.

Posted on Jul 19, 2008

MicrowaveSvc
  • 9047 Answers

SOURCE: GE microwave Turnable turns on opening the door

Thanks for the photo of the label!

It shows the FCC ID number, which I used to find schematics at the FCC Web site.

The problem is a shorted primary interlock switch.

This is the door switch which has two black wires connected to one terminal and a black and a blue wire connected to the other
terminal.

See these files for help:

http://www.microwavedisplay.com/safety.txt
http://www.microwavedisplay.com/disassembly.txt
http://www.microwavedisplay.com/doorsw.txt

You can usually find helpful exploded view diagrams and order parts by entering your full model number here.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Posted on Jan 23, 2009

MicrowaveSvc
  • 9047 Answers

SOURCE: GE Advantium 120 Microwave fan stays on, off only when door open

Looking at the schematic in the service manual here, I would say relay RY6 on the small sub PCB (relay board) has shorted contacts.

That's the relay that runs both the fan and turntable.

It's possible that it may be a bad connection or driving component on that board, but in my experience, it's virtually always a stuck relay.

The part number on the relay as shown in the photo is hard to read, but it looks like "OJ-SH-112LM".

I should have one of these or I can point you to one if you want to contact me with the exact number.

Feel free to contact me directly (and please remind me of your full model number) for more information & help.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

William E. Miller
prototech@usa.net
http://www.microwavedisplay.com

7e1615b.jpg

Posted on Jan 31, 2009

ginko
  • 19396 Answers

SOURCE: light bulb not working on my ge microwave model JVM1870SK03

Replace the light bulb, if that is not enough , check contact to lamp holder.

If microwave is not working at all, check also door switch , fuse, and control panel.

All locations, and description of this parts can be located using the diagram here: Counter top.

Parts must be tested to find out what is wrong.

Remember that microwaves are potentially dangerous devices if not repaired properly, the job must be done by a competent person.
A microwave energy leakage test must always be performed when the oven is serviced for any reason.

Regarding parts, contact the seller here to purchase parts. (here in UK).

Posted on Apr 27, 2009

  • 1 Answer

SOURCE: Active vent keeps opening and closing though fan is off.

When the unit begins the never ending opening and closing cycle, turn the vent fan on for a few seconds and then turn the fan off. This seems to stop the active vent from opening and closing. If this is GE quality, this is the last thing that I am going to purchase. GE refrigerators are garbage and now I am having problems with a new microwave oven.

Posted on Mar 27, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Fan runs when door is closed and no time set.


Some GE units were starting on their own. I would definitely unplug this oven and call GE to make sure yours wasn't one of the ones being re-called.

Feb 14, 2013 | GE Advantium 120 Convection/Microwave Oven

1 Answer

I have a GE microwave. Beginning last night, the inside light stays on with the door open and when you close the door, the cooling fan starts up and the light stays on. The turntable doesn't rotate an


You have a major electrical issue within the microwave......potential electrical fire hazard. Unplug it and get a new one. Circuit boards are usually the same as the replacement price.

Nov 08, 2012 | Microwave Ovens

1 Answer

Siemens HF26066GB plate is moving when door closed and not moving when open


Have a shop look at this---there usually is a recessed safety switch inside the jam that will prevent the unit from working with door open--sounds like the problem may be with it.

Nov 03, 2012 | Siemens HF26066GB 1000 Watts Microwave...

1 Answer

GE Spacesaver Microwave not heating, inside fan not working


I suggest you have the microwave oven replaced, the prices have dropped considerably for the last several years and you have got your money worth out of the unit.

Mar 02, 2012 | GE JVM1640 Microwave Oven

1 Answer

GE Advantium Microwave section doesn't work.


The primary interlock switch on my Advantium has failed twice. The replacement part is available at: appliancepartspros.com part no. for my Advantium was AP2622452 and it cost $11.74 + $6.95 shipping.

For what it's worth, my nylon connector and wire covering were also scorched a bit but the last primary interlock switch lasted me for over a year.

Please note that I am not an expert at repairing appliances and that I assume no responsibility or liability for any attempt you may make to repair your own appliance.

May 30, 2009 | GE Advantium SCA2000B Microwave Oven

1 Answer

Light bulb not working on my ge microwave model JVM1870SK03


Replace the light bulb, if that is not enough , check contact to lamp holder.

If microwave is not working at all, check also door switch , fuse, and control panel.

All locations, and description of this parts can be located using the diagram here: Counter top.

Parts must be tested to find out what is wrong.

Remember that microwaves are potentially dangerous devices if not repaired properly, the job must be done by a competent person.
A microwave energy leakage test must always be performed when the oven is serviced for any reason.

Regarding parts, contact the seller here to purchase parts. (here in UK).

Apr 25, 2009 | GE Spacemaker JVM1640SJ Microwave Oven

1 Answer

GE microwave won't turn off


Just checked the GE website. Had the same problem with my 5 year old microwave. GE website says to close and open the door quickly three times. First time I did this it didn't work. Second time I closed the door with some significant force and reopened it more quickly. Worked. Unplugged the microwave, plugged it back in, still fine.

Mar 21, 2009 | Microwave Ovens

Not finding what you are looking for?
Microwave Ovens Logo

Related Topics:

104 people viewed this question

Ask a Question

Usually answered in minutes!

Top GE Microwave Ovens Experts

D. E. Hev

Level 3 Expert

1167 Answers

 Larry
Larry

Level 2 Expert

115 Answers

Shekar Avadhani

Level 2 Expert

61 Answers

Are you a GE Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...