Question about Coleman Powermate 7,000 Watt 13 Hp Portable Generator #PM0497000

1 Answer

No electrical output or no electricity

I purchased this unit at Sam's club one year ago. Started it and realized it had no voltage output. After reading the manual, I believed my problem was that the generator needed to be re-excited. Today, one year later, I called them to ask for proper procedure and they told me that my unit was different that the one shown in the manual and mine doesn't ever need to be excited. Anyone have the same problem and if so, what part needed to be replaced. I ask this because the company went bankrupt in March. Just my luck.

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 3 Answers

Demand sams take it back, or give you a working one. They sold it, they need to handle their end of the deal. If they don't back there product, put it in the news.

Posted on Dec 19, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I need a rectifier or avr for generac 3500 xl genarator


Ebay and various places including the maker..

  • VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR-GENERATORS ... www.ebay.com/sch/sis.html?_nkw=VOLTAGE-REGULATOR-3000-3500-WATT... VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR ... New listing 3500 Watt Generator AVR Automatic ... 3500W Generator AVR Automatic Voltage Rectifier ...
  • 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator ... https://sites.google.com/site/kltthtyz0i04cd/3500-w-3500-watt... Generac Guardian 22kW Standby Generator NG ... Previously Pay for Shop 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator Rectifier 3.5KW Generator AVR ...
  • How to test your Electricity Generator's AVR, Brushes and ... www.youtube.com/watch?v=tC_LrrZcx38
    • BY GENERATOR GURU
    • 9 MIN
    • 454K VIEWS
    2011-10-21 · Video embedded · When your electricity Generator stops producing power, ... How to test your Electricity Generator's AVR, ... Generac iQ: The Quietest Generator ...
  • Generac Power Systems - Home www.generac.com Generac manufactures the widest range of power products in the marketplace including portable, RV, residential, commercial and industrial generators.
  • Generac Guardian Generator Voltage Regulator Rectifier ... www.ebay.com/sch/sis.html?_nkw=Generac+Guardian+Generator+Voltage... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator ...
  • Automatic Voltage Regulator (AVR) for Generators portable.generatorguide.net/avr.html How automatic voltage regulator (AVR) works in portable generators: ... here you can see a reverse engineered Generac regulator that uses SCRs and UJT.
  • Diagnosing A Generator That Has No Power Output. - YouTube Youtube
    • BY THEDIYGUYDOTNET
    • 3 MIN
    • 150K VIEWS
    2012-11-12 · Video embedded · Diagnosing A Generator That Has No Power Output. ... How to test your Electricity Generator's AVR, ... Generac Portable Generator ...
  • GENERATOR Diagram & Parts List for Model 3500xl Generac ... www.searspartsdirect.com > ... > 3500XL GENERAC Generator-Parts GENERATOR Diagram and Parts List for GENERAC Generator-Parts model # 3500XL ... Generator rectifier Part #: ... Generator voltage regulator Part #: ...


  • Jun 28, 2016 | Generac Electrical Supplies

    1 Answer

    Where can I get an owners manual ?


    PDF]10000W Generator

    scene7.samsclub.com/is/content/.../GG10020-Eng%20manual-cpdf
    Gentron/UPC will repair or replace, at Gentron/UPC's sole option, products or components ... Expendable parts or accessories supplied with the product which are..... FILLED WITH OIL OF A HIGH QUALITY SAE 10W-30 GRADE ENGINE OIL.

    Gentron - 10000 Watt Gas Generator with Electric Start

    www.samsclub.com > Sam's Club > Emergency Supplies

    Sam's Club
    Rating: 4.4 - ‎330 reviews
    Gentron 8,000W / 10,000W Portable Gas Powered Generator with Electric Start ...... 1 year parts and labor limited manufacturer's warranty; For issues not ...

    Gentron Pro2 10000w Gas Generator (GG10020)

    https://generatornow.com/gentron-gg10020-pro2-10000w-gas-powered-...
    Gentron GG10020 Pro2 10000w Gas Powered Portable Generator with Electric ... It's a one year/1000 hr parts and labor warranty for our residential customers.

    Jan 21, 2016 | Electrical Supplies

    1 Answer

    My Yamaha Ef2400iS inverter shuts off when I use my 3/8th electric drill. This problem started last fall. I could use the drill and portable saw, not at the same time, since the inverter was new three...


    yes, the problem is that electronic/electrical components age with use. especially voltage regulators and switching transistors. as they age they can no longer sustain the current you are demandiing from the unit. the units are designed to run in the middle zone, not at full maximum load all the time, if you do that you will weat it out quicker. Always buy a power supply that is double your intended wattage and it will last many years. Hope this answers your question

    Mar 21, 2011 | RTO New Yamaha Inverter Ef2400is / Yamaha...

    1 Answer

    I have a situation where it worked perfect (output) , went to use it other day....only puts out half output. when i go to plug a drill, it revs up, but wont turn the drill or anything else ...


    first need to check and see how much electricity it is making or its out put it should be 120 volts,,,sounds like it is not making enough electricity check all electrical connections,,,something is loose

    Feb 18, 2011 | NEC Mitsubishi MGE 4000 Generator ROU...

    1 Answer

    I purchased a Coleman Powermate 5000 6 years ago: Ser: 94411583. Never really used it for any length of time. Kept for emergency. An electrician checked it for voltage output a short time ago. 240V...


    Voltage is adjusted by raising or lowering the engine speed (governor adjustment), however one must also pay attention to the rpm because your generator was designed to produce 120 volts at 60 cycles while turning 3600 rpm. Your electrician should have tested for htz while testing for voltage. I would recommend re-testing under load and adjust governor to turn 60 cycles to see resulting voltage.

    Sep 30, 2010 | Coleman Powermate Powermate 5000W...

    1 Answer

    I have an ACDELCO 6500 Watt Electric Start Generator. i bought it brand new about 1 year ago and it started up with no problems. Unfortunately I did not drain the gas after using it and it sat idle with...


    Fuel will go stale if left for a long time. Drain and clean fuel tank and also drop float bowl on carburettor to remove any old fuel. If there is any sediment in the float bowl a carby clean could also be necessary.

    Aug 24, 2010 | BUFFALO ACDelco 6500 Watt Generator...

    1 Answer

    I have a mc5500 generator that worked fine about a year ago. I started the engine yesterday and ran fine, but no power. I feel that the thing needs to be field flashed. I have searched the web and found...


    My guess is that the board or rectifier is your problem. To Flash it you would have to unhook the board and flash it through the wires coming directly from the stator.

    Nov 27, 2009 | Electrical Supplies

    2 Answers

    My Coleman Powermate 6250 generator has no power output. After the carburator was cleaned, I flashed it. A voltage meter shows there is power being generated, but none so to light a light bulb. What to do...


    Take the cover off and flash the rotor again with a 12 volt battery. Positive lead goes to the top or right side brush. Negative to the other brush. Just touch it on, then remove it, and check for power at plugs.
    If that doesn't do it, change the AVR (voltage regulator)

    Aug 05, 2009 | Coleman Powermate Premium Plus 6250W...

    1 Answer

    No output from my generator


    There is no such thing as "remagnatized" thats horrible and stupid advice. Your engine once started turns an alternator, which that produces electricity. Check all wiring connections first, if everything looks okay, you may need to replace the alternator.

    Jul 28, 2009 | Coleman Powermate 5000W Home Backup...

    1 Answer

    No electrical output


    It is possible that your voltage regulator is shot but before purchasing the volt regulator try flashing the fields first and make sure the brushes and rings are clean.

    Feb 13, 2009 | Generac Guardian 065795 - battery charger...

    Not finding what you are looking for?
    Coleman Powermate 7,000 Watt 13 Hp Portable Generator #PM0497000 Logo

    311 people viewed this question

    Ask a Question

    Usually answered in minutes!

    Top Coleman Electrical Supplies Experts

    John Trevino

    Level 3 Expert

    1378 Answers

    Shawn DuRee

    Level 3 Expert

    355 Answers

    Phil Rivera

    Level 2 Expert

    83 Answers

    Are you a Coleman Electrical Supply Expert? Answer questions, earn points and help others

    Answer questions

    Manuals & User Guides

    Loading...