Booting problem After memory test done. it hangs there. it does not go to next screen. Not even able to login to BIOS setup

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Guru:

    An expert who has written 7 tips or uploaded 3 video tips

  • Master
  • 829 Answers

Did you replace the RAM and try if still persists then there could be problem with the RAM.

Posted on Dec 17, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

What is 3-3-2 beep tone meaning


System doeIf there is one DIMM in the system the memory row/bank may be disabled when there is a memory failure. The system will not boot because it has no memory to use. If the DIMM is replaced with one of the exact same type and size, then the system will continue not to boot. BIOS cannot tell when a DIMM has been replaced with one of the exact type and size, therefore BIOS believes it is still the bad DIMM and will not use it.

Here are two possible workarounds:

1. After replacing the defective DIMM, continue to reboot the system until you hear the "no memory" post beep sequence (3-3-3) during POST (no video display). After three (3) incomplete boots, a "062 three consecutive boot failure. Using default CMOS configuration caches are off" error will occur. At this point BIOS will go back to the default settings and begin to use the new DIMM. However, if you have disabled the 3 boot fail count (this setting may not be available in all servers) in Setup, then BIOS will not turn the DIMM row/bank back on.
-=OR=

2. Remove the DIMM. Power on the system until the "no memory" post beep sequence (3-3-3) is heard. The memory row/bank will now be marked as being empty. Power off the system and put a good DIMM back into the system. The memory DIMM row/bank is re-enabled and the system boots normally.

NOTE: If more than one DIMM (or more than one DIMM set) is installed in the server and one memory (or one memory set) row/bank is disabled due to a memory failure then, the user must go into setup and re-enable the row/bank after replacing the bad DIMM.
Additional information
s not boot after replacing memory DIMM Servers

Jun 11, 2014 | IBM Netfinity 5600 8664 Server

1 Answer

Poweredge 1950 won't start


this is common, if your place was cold its possible that something has died when turning on again, you could try and pull out ram in an order to see if one has failed, get the memtest download and make a boot disk to test the ram has not become faulty, test each stick alone, Hiren boot disk has all the good stuff for testing, its a free tecky tool for engineers.

Feb 13, 2013 | Dell POWEREDGE 1950 Server

1 Answer

How to change bios settings, i.e model/type serial number, enable.disable memory banks


Boot the system
Press F1 to enter the Configuration/Setup Utility
to change bios settings, i.e model/type serial number, enable.disable memory banks

Oct 06, 2009 | IBM xSeries 366 Server

2 Answers

Dell Poweredge 4300 will not boot up after cmos battery replaceme


Configure your System bios and reboot. Your Hard disk drive was not configured. Pl configure. it will work properly

Aug 22, 2009 | Computer Servers

1 Answer

I just got this machine and it hangs on the POST (with video) about 1/4 of the way. This is before the F2 or F10 message comes up. Two days ago, I took the CMOS battery out and put it back in and it did...


POST errors can be difficult to diagnose.

If you have a speaker attached, listen for a sequence of short and long beeps, and pauses between. Record the sequence, this is a code that tells what the POST diagnostic is.

Other start up BIOS keys are F2, F6, F8, F10 and F12; when I don't know which one it is, I just hit all of them.
Whether it's stated or not, you can usually hit these keys during the memory count, (The second Self Test after video)

If the Memory Count dosn't finish and the BIOS open, then perhaps a dammaged memory chip is the cause. Try Rearranging the chips, or removing all but one of them and try the boot sequence.

This may not be a solution but further info can be gained by trying these.

Jun 18, 2009 | Dell PowerEdge 4400 Server

2 Answers

Server error


The System Event Log may become full of erroneous IPMI Events reported by the System BIOS. When this occurs, the following message may appear during Power-On Self-Test (POST) and POST cannot continue without user input:
02a2: BMC System Error Log (SEL) Full
Press F1 to Continue, Press F2 to Setup
If the above message appears during POST, perform the following steps to run BIOS setup and delete the System Event Log:
  1. Boot the server and press the F10 key when prompted to run BIOS Setup.
  2. Select the "Advanced" menu.
  3. Scroll down to "IPMI" and press the ENTER key
  4. Scroll down to the System Event Log and press the ENTER key.
  5. At the "Clear System Event Log" selection, press the ENTER key to toggle between "Enable" and "Disable."
  6. Select "Enable."
  7. Press the F10 key to Save the changes and exit the BIOS Setup.

Mar 02, 2009 | HP Compaq ProLiant ML110 G4 Server

1 Answer

No video at all


try first with one cpu and only one stick of memory in socket zero

if the video does not come on... try next to reset the bios .. clear the settings... it may be setup to search for a pci or pci-e video card in the bios

next try to test the wattage being pulled into the system at boot... should be over 200watts.. may indicate a power issure

are there any beep codes ... post codes or ... is there a single beep tone during power on to verify the motherboard is functional and checks out fine at self start...

mark@omces.com

Aug 22, 2008 | Tyan Transport TA26 Server

1 Answer

Hp proliant ml370 g4 rebooting problem


Try to boot from smart start and do offlinr diagnostics.have you purchased second cpu seperately? Check the CPU compatibilities.

Jul 16, 2008 | HP ProLiant ML370 G4 Server

2 Answers

Can not access bois


It hangs there probably becuase one or more of the drives are dead or are almost there. Check and see the lights on the drives are falshing funny or too long or are yellow. If you find one of them that are that way, pull it out and then reboot.

See if that helps.

Nov 07, 2007 | Dell PowerEdge 1600SC Server

Not finding what you are looking for?
Tyan Transport GT24 (B2891G24S4LC) Server Logo

Related Topics:

178 people viewed this question

Ask a Question

Usually answered in minutes!

Top Tyan Computer Servers Experts

joecoolvette
joecoolvette

Level 3 Expert

5660 Answers

Les Dickinson
Les Dickinson

Level 3 Expert

18304 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17129 Answers

Are you a Tyan Computer Server Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...