Question about Sharp XE-A404 PC Desktop

7 Answers

Sharp XE-A203 Cash register Error message 3.2

How does one remedy this error and continue work?

Posted by on

  • 2 more comments 
  • sudheer546 Jan 13, 2009

    i gone through the manual but i am unable to solve this ...
    can you please elaborate briefly ho to solve this

  • almazkassa1 Apr 08, 2009

    My Sharp XE-A203 has an error how can i solve it?
    The Error is error message 3.2.


  • dandkmasonry Apr 09, 2009

    error message 3.2 Need help business cash register

  • Anonymous Mar 22, 2014

    cannot press any keys with E2 error

×

7 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 737 Answers

You have logged yourself out of the machine. Press CL then 1 then CLK# or CASH#

Posted on Jun 06, 2010

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 3 Answers

Press clear key type one then the clerk key

Posted on Sep 20, 2009

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

Sharp cash reigster with an error message 3.2

Posted on Apr 09, 2009

  • nimalarmy Mar 16, 2012

    I can't punch price. ER 3.2

×

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 360 Answers

Press cl key and 1

Posted on Jul 06, 2010

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

I went to the manufacturer's website and downloaded the information and manual in pdf format. All information needed was there, and the problem was resolved in a matter of minutes.

Posted on Dec 15, 2008

  • nimalarmy Mar 16, 2012

    No work

  • nimalarmy Mar 16, 2012

    How to remo ER32

×

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 3 Answers

Cash register error

Posted on Jan 17, 2009

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 9 Answers

Why struglle with this, call cash register helpline for United Kingdom, call charged at £1 per minute :- 0905 105 0159

Posted on Feb 13, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Why is it showing error code 90?


Sounds like a all the bells and whistles thermostat, why did you chose that one?
090 Data interface is continuously busy.
A log of error codes can be viewed at the end of the installer setup after the system tests. Active errors will be shown first. The Error Log will log the last ten errors (active and inactive).
Pressing the reset button will clear all inactive errors from the
error log; active errors can not be cleared until the condition has been remedially busy

Dec 27, 2015 | Honeywell TH9421C1004 VisionPRO IAQ Total...

1 Answer

Error code f51 flashing. What's wrong?


David: Try downloading this free user manual: http://laundry.manualsonline.com/manuals/mfg/miele/pw_6065.htmlk According to ApplianceHelponline.: " Heater pressure switch The program is interrupted and the drain pump is operated. The display shows Technical fault F51. Call Service Department. The buzzer is activated for 2 minutes.

Background information:

Start position: One second after the program start, heater relay K1/1 is activated. This enables a check as to whether the contacts on heater pressure switch B1/13 have closed on switching steps 21/22 or 11/12.

Cause:
Heater relay defective; contact open.

Remedy:
Replace the heater relay.

Cause:
Heater relay solenoid defective.

Remedy:
Replace the heater relay.

Cause:
Connection from heater relay to electronic module open-circuited.

Remedy:

1. Check plug connections.

2. Check the connection wires for continuity.

Cause:
Heater pressure switch open- or short-circuited.

Remedy:
Replace the heater pressure switch.

Cause:
Connection from heater pressure switch to electronic open-circuited.

Remedy:

1. Check plug connections.

2. Check the connection wires for continuity.

Cause:
Foreign objects in heater pressure switch.

Remedy:
Replace the heater pressure switch."

May 14, 2015 | Miele Washing Machines

1 Answer

What is Technical Fault 51? It appeared a few moments ago on our machine, but when I switched it off and reset the machine it worked as normal again.


F51 Heater pressure switch The program is interrupted and the drain pump is operated. The display shows Technical fault F51. Call Service Department. The buzzer is activated for 2 minutes.

Background information:

Start position: One second after the program start, heater relay K1/1 is activated. This enables a check as to whether the contacts on heater pressure switch B1/13 have closed on switching steps 21/22 or 11/12.

Cause:
Heater relay defective; contact open.

Remedy:
Replace the heater relay.

Cause:
Heater relay solenoid defective.

Remedy:
Replace the heater relay.

Cause:
Connection from heater relay to electronic module open-circuited.

Remedy:

1. Check plug connections.

2. Check the connection wires for continuity.

Cause:
Heater pressure switch open- or short-circuited.

Remedy:
Replace the heater pressure switch.

Cause:
Connection from heater pressure switch to electronic open-circuited.

Remedy:

1. Check plug connections.

2. Check the connection wires for continuity.

Cause:
Foreign objects in heater pressure switch.

Remedy:
Replace the heater pressure switch.

Apr 14, 2015 | Miele Washing Machines

1 Answer

My sharp al2021 showing f5-02 and e7-11 what can do to work


The service manual was not available for the AL-2021 but the error codes are the same for the AR-5316
F5-02 error cause and remedy
Sharp AR 5316 Service Manual Page 27
E7-11 error cause and remedy
Sharp AR 5316 Service Manual Page 26

Jan 07, 2015 | Office Equipment & Supplies

1 Answer

How to fix anti flood error on F60860


Error "i30" means that water remains in base because leakage or overflow. In this case, in order to prevent flooding, drain pump running continuously.
When we talk about AEG dishwasher, drain pump works even the power is turned off (must be connected to the wall outlet, otherwise anti-flooding system will not work).
Remedy: you should first remove the water from the bottom of the dishwasher and determine leakage.

If you work around the dishwasher, you always take care that appliance must be disconnected from the power supply.

Dado

Sep 28, 2014 | AEG 24 in. Favorit 60870M Free-standing...

1 Answer

My washin machine is just stopping thru cycles and beeping continuously until I switch off - reading E3. My father thinks it might be the heater, is that right. I'm having a lot of trouble getting...


Hi, the E3 error is comes up when the water heater element does not work properly or the filter mesh is blocked. Remedy: Clean the filter mesh and if the problem continues, the main board needs to be replaced.

Jun 24, 2011 | Maytag 24 in. MDB6600A Jetclean II...

1 Answer

Maytag jetclean Model number MJD 3000 AAW Problem : E3 error towards end of cycle


Hi,

Cause: The water heater element does not work properly or the filter mesh is blocked.
Remedy: Clean the filter mesh and if the problem continues, the main board needs to be replaced.

The Filter mesh in the bottom of the appliance.

Let me know,if needed further assistance.

Hope i helped you.

Thanks for using ' Fixya ' and have a nice day!!

Jun 14, 2011 | Dishwashers

1 Answer

MY COPIER (KYOCERA 1635) DISPLAS ERROR C6050. HOW


C6050 Abnormally low fuser unit thermistor temperature The fuser temperature remains below 90°C/194°F for 1 s. Poor contact in the thermistor connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Broken fuser thermistor wire. Measure the resistance. If it is ∞ ω, replace the fuser thermistor. Fuser thermistor installed incorrectly. Check and reinstall if necessary. Fuser thermostat triggered. Check for continuity. If none, replace the fuser thermostat. Fuser heater M or S installed incorrectly. Check and reinstall if necessary. Broken fuser heater M or S wire. Check for continuity. If none, replace the fuser heater M or S. Code Contents Remarks Causes Check procedures/corrective measures

Apr 09, 2010 | Copystar CS-1620 Copier

1 Answer

I have a Maytag MAH-24 that is giving me an E3 error.


E3

Cause: The water heater element does not work properly or the filter mesh is blocked.
Remedy: Clean the filter mesh and if the problem continues please contact service

Mar 14, 2010 | Washing Machines

1 Answer

Codigo C7760 de una Kyocera kilometros 1635


C7410 C7800 C7810 C8010 C8030 Drum unit connector insertion problem • Absence of the drum unit is detected continuously for 1500 ms while there is no error on the copier. Broken external temperature thermistor wire • The input voltage is above 4.5 V. Short-circuited external temperature thermistor • The input voltage is below 0.5 V. Finisher* paper conveying motor problem • The paper conveying motor lockup signal is detected for 0.5 s or longer. Finisher* paper conveying belt problem • An on-to-off or off-to-on state change of the paper conveying belt home position sensor is not detected within 2 s of the paper conveying belt clutch turning on. Drum unit connector inserted incorrectly. Defective drum unit connector. Poor contact in the humidity sensor PCB connector terminals. Defective external temperature thermistor. Poor contact in the humidity sensor PCB connector terminals. Defective external temperature thermistor. Poor contact in the paper conveying motor connector terminals. The paper conveying motor malfunctions. Defective finisher main PCB. The paper conveying belt is out of phase. The paper conveying belt clutch malfunctions. The paper conveying belt home position sensor malfunctions. The paper conveying belt home position sensor connector makes poor contact. The internal tray is incorrectly inserted. Reinsert the drum unit connector if necessary. Replace the drum unit. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the humidity sensor PCB. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the humidity sensor PCB. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the paper conveying motor and check for correct operation. Replace the finisher main PCB and check for correct operation. Adjust the paper conveying belt so that it is in phase and check for correct operation. Replace the paper conveying belt clutch and check for correct operation. Replace the paper conveying belt home position sensor and check for correct operation. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Check whether

Jan 19, 2010 | Office Equipment & Supplies

Not finding what you are looking for?
Sharp XE-A404 PC Desktop Logo

Related Topics:

5,825 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sharp Retail Supplies Experts

k24674

Level 3 Expert

7993 Answers

kakima

Level 3 Expert

100322 Answers

Electroboy
Electroboy

Level 3 Expert

1548 Answers

Are you a Sharp Retail Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides