Question about Paragon 8145-20 Defrost Timer

1 Answer

Paragon timer parts

Where can I purchase Paragon clock motors and points replacement kits?

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Contributor
  • 52 Answers

Electricalexpeditors.com

Posted on Oct 05, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Can you show me paragon timer 4003-0 the wiring


1) Copy following links:
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000
http://waterheatertimer.org/images/Paragon-4000-series-wiring.jpg

2) 4003-0 is 120Volt timer so clock voltage is 120V
Timer can control 120V or 240V loads
Use diagram 3

3) Paragon is no longer making this timer or parts for timer.
If you purchased timer from ebay, then assume motor is bad or X2772 trippers are worn out.
Always buy new timers. Buy Intermatic and parts are easily available.

4) Replacement timer is Intermatic T101

Feb 16, 2013 | Paragon Timers

1 Answer

The clock on my paragon 4004-71m is not working


1) Clock motor has gone bad, but replacement clock motors are no longer made.
Copy following link for Paragon resources:
http://waterheatertimer.org/Paragon-timers-and-manuals.html

2) Paragon is not making parts or replacement motors.
4007-41 is 240Volt timer, replace timer with Intermatic T104
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html

3) Crossover wiring from Paragon 4004-71 to Intermatic T104:
Paragon 1 to Intermatic 1
Paragon 2 to Intermatic 2
Paragon 3 to Intermatic 4
Paragon 4 to Intermatic 3
Intermatic terminal A is generally not used for 240Volt

4) Add a comment if needed

Jan 17, 2013 | Paragon Timers

1 Answer

The relay on my Paragon 1015-00RS timer has gone bad,, where can a purchase another one


You won't be able to find parts for that timer unless e-bay is selling used timer.
Patriot supply sells new timer, Aug 2011:
http://www.patriot-supply.com/products/manufacturer_detail.cfm?manu_id=191

Paragon is no longer making timers and parts except defrost timers.
http://waterheatertimer.org/Paragon-timers-and-manuals.html

Intermatic crossover timer is 120Volt T1975, which sells for less and has replaceable 156T1978A trippers and WG733 clock motor. Relay is not replaceable part.
http://www.intermatic.com/products/ec%204%20layer/mechanical%20time%20switches/24%20hour/t1900%20t1970%20series.aspx

Aug 15, 2011 | Paragon 1015-00RS Indoor Multi Operation...

1 Answer

Timer does not work properly timer motor not count proper time


If the clock motor is not keeping correct time, then it has gotten weak and needs to be replaced.
Paragon is still making defrost/HVAC timers and parts.
Clock motors have numbers.

Mar 28, 2011 | Paragon Electric A-706-00 Hvac Timer...

1 Answer

I need to purchase 6 (six) more sets, 1 on and 1 off, trippers for the churches' 7 day timer. Do you need to know voltage of motor? The voltage it is switching is 240 volt.


1) You posted under paragon 7008-00 timer.
It is not necessary to know voltage of motor to order tripper

2) Model number of timer is usually located on inside door panel

3) Paragon is no longer making timers or parts.
Open following link to identify timer for sure:
http://waterheatertimer.org/Paragon-timers-and-manuals.html#7000
http://waterheatertimer.org/Boxtype.html

4) Following link from Paragon gives links for folks who might still sell parts:
Expect some suppliers to overcharge for parts.
I've seen paragon trippers selling for $60.
http://portalgb.knowledgebase.net/display/1/index.aspx?c=15121&cpc=XobrEdQ5Lsnv624T2PBS4Exx6S5VyiL7gw3am4YYt6&cid=13013&cat=&catURL=&r=0.485034763813019

5) It might be easier to buy another time clock.
Refer to Intermatic Competitive cross reference chart.
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx
For example replacement for 7008-20 is Intermatic T7802B which is a 7-day, 40 amp 240V timer.
http://www.intermatic.com/products/timers/mechanical%20time%20switches/7%20day%2040%20amp.aspx

6) You are working for your church, probably as a volunteer.
I also volunteer several places in my community.
I have extensive files on timers and can help you choose and install a new timer if I know the model number.
Just add a comment to this post and I will answer if needed.

Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, expert speaks with you over phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Feb 07, 2011 | Paragon Amf 7008-00 Timer 7 Day 120 Volt...

1 Answer

Not keeping correct time


You posted under Paragon 4001-00 120Volt SPST timer

1) If timer is not keeping correct time, generally you need to buy new clock motor.
However Paragon is no longer making timers and parts, except for defrost timers.
4001-00 is not defrost timer.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#Paragon4000

2) You probably need to replace timer
Intermatic cross reference shows T101 timer is correct replacement.
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx

3) Amazon sells T101 for $43.
This price is a lot lower than trying to find somebody who has specific Paragon clock motor
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN

4) Grainger and many other places sell T100 series replacement trippers and motors.
No worry about defunct product

5) Wiring for T101 appears below:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Cross-over wiring is as follows:
Paragon terminal 1 goes to T101 terminal 1
Paragon terminal 2 goes to T101 terminal 2
Paragon terminal 3 goes to T101 terminal A

Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, expert speaks with you over phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Jan 27, 2011 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

Hello I need to replace a paragon model 4003-0 can you tell me what is compatable to this model? thanks maury


As you probably know, Paragon is no longer making timers and parts except defrost timers.
4003-00 is not a defrost timer
4003-00 is DPST 120Volt timer 24-hour mechanical timer
Paragon timers and manuals
http://waterheatertimer.org/Paragon-timers-and-manuals.html

Intermatic cross reference shows that T-103 is replacement for 4003-00
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx

http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T103
T-103 has 120Volt clock motor and can control 1 or 2 - 120V loads or 1 - 240Volt load

Dec 29, 2010 | Paragon GENERIC REPLACMENT MECHANISM 110V...

1 Answer

Where do I get a replacement motor for the 7008-00?


Intermatic clock motors are everywhere, but Paragon and Tork clock motors are a mystery.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#7000
Shows manuals and resources

According to Paragon accessory chart:
http://www.paragontimecontrols.com/parts_accessories.htm
7000 series 240V clock motor M3193-71
7000 series 120V clock motor M3099-00

7008-00 is listed as 120V clock motor
http://waterheatertimer.org/pdf/Paragon-7000-series-manual.pdf

I cannot find M3099 120V clock motor on internet
Now Paragon has contact-us page for customer service:
http://www.paragontimecontrols.com/contact/default.aspx

I will also contact Paragon, and post results here if Paragon responds.

Nov 17, 2010 | Paragon Amf 7008-00 Timer 7 Day 120 Volt...

1 Answer

AMF Model No. 7008-00 How do I know if it is working or not. Where can I get more Pins to stop the bld everyday at 5pm.


Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;}

Paragon 7008-00 timer parts:
http://www.paragontimecontrols.com/parts_accessories.htm
http://www10.shopping.com/-paragon+timer+trippers

Paragon mechanical 7008-00 has 120V clock motor
-8 poles control 1-4 separate 120V loads, with 2 NO Normally Open and 2 NC Normally Closed circuits with max 690 Watts per pole.

Test 120V clock motor:
-Clock motor connects to two far right terminals. Black hot to pole M, White neutral to pole T.
-You should be able to hear clock motor running by putting ear against outside case.
-Clock motor will rotate wheel, if wheel is not rotating, then motor is not running.

Sep 21, 2010 | Paragon Amf 7008-00 Timer 7 Day 120 Volt...

Not finding what you are looking for?
Paragon 8145-20 Defrost Timer Logo

Related Topics:

1,603 people viewed this question

Ask a Question

Usually answered in minutes!

Top Paragon Timers Experts

Steve

Level 3 Expert

3287 Answers

Andrew Taylor
Andrew Taylor

Level 3 Expert

10628 Answers

Gene Haynes

Level 3 Expert

5080 Answers

Are you a Paragon Timer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...