Question about RCA P52960 52" Rear Projection Television

1 Answer

Tv does not come on

My tv ge 52 inch 2004 power does not come on, green light comes for 2 seconds then goes off, comes on again, this happens three times, then it won't come on again for 90 secs, and the process repeats itself again, but the tv does not come on, it used to hours now it's days turn in, what is going on and is there a recall on this model d52gw12?
serial # e436c3093.. if not it should be. thanks.

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Genius:

    An expert who has answered 1,000 questions.

  • Contributor
  • 1,199 Answers

IT SOUNDS LIKE A FLYBACK NEEDS REPLACED (PART COST AROUND $70.00

Posted on Dec 06, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

I have a GE 52 inch projection screen TV. I have replaced three CP's: 150, 114, 120. I also replaced the flyback. The TV worked only a couple of times. I turned it on, then off, and right back on. I only...


You can start with resolder deflection board around Hori output, coils and Big diodes also make sure 2 ribbon connectors are pushed in correctly and in good CK Both Ribbons .

Mar 24, 2010 | GE D52GW12 52" Rear Projection HDTV-Ready...

1 Answer

Tv's green light comes on then off three times


Check capacitors cp150 ,114, 120 ,if cp150 is puffed up on top it is bad.2200uf 16v and the other 2 are 220uf 35v.

Feb 11, 2009 | RCA D52W20 52" Rear Projection HDTV-Ready...

2 Answers

GE 52" will not power up - green light flashes 3 times


Replace CP150 and CP114 and CP120/ You can get the caps with instructions at the following link. They do have a minimum order amount of 10.00 so you may need to order an extra capacitor to total 10.00 but shipping is free. The parts are listed under the RCA parts category,
http://servicemanuals.vstore.ca/

Feb 07, 2009 | GE D52GW12 52" Rear Projection HDTV-Ready...

1 Answer

I have a 52" GE-HDTV/Monitor. After the unit is turned off, it will not come back on-at all now. When I try to turn it on, the green light on the front of the TV comes on briefly, then goes off. I can...


replace CP150 CP114 and CP120 all three capacitors are available at the following link with free instructions they are listed under the RCA parts category which are the same ones for your GE TV.
http://servicemanuals.vstore.ca/

Jan 17, 2009 | GE D52GW12 52" Rear Projection HDTV-Ready...

1 Answer

Power will not stay on


You probably have capacitor CP150 bad on the power/deflection board. The capacitor is a 2200 microfarad at 16 volt cap. This component should be changed by a qualified tech

Dec 02, 2008 | GE D52GW12 52" Rear Projection HDTV-Ready...

2 Answers

Won't come on


hy i got a toshiba 42" LCD tv ,when i press the power boton
iget the red light,& it stay that way ontil i pressthe power back off
thanks for any help

Jun 26, 2008 | Toshiba 62HM95 62" HDTV

Not finding what you are looking for?
RCA P52960 52" Rear Projection Television Logo

65 people viewed this question

Ask a Question

Usually answered in minutes!

Top RCA Projection Televisions Experts

The Wyzzyrd

Level 2 Expert

83 Answers

D. E. Hev

Level 3 Expert

1059 Answers

Ron Dufek
Ron Dufek

Level 3 Expert

398 Answers

Are you a RCA Projection Television Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...