Question about Compaq UPS Battery Backup Systems

1 Answer

Continuously beeping compaq 1000va ups beeps as if it is on battery even when there is utility power

Posted by on

  • Gav Shaw May 11, 2010

    How long do the Beeps last? and are do they have the same length pause in between them or does it differ?\

    IE - Beep Pause Beep Pause Beep Pause
    or 
    Beep Pause Beep Beep Pause Beep.

×

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Governor:

    An expert whose answer got voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 189 Answers

Hi,
Was the ups charge? If it was not charge, have charge for a couple of hours means that with no computer attached or computer off.
If still continues have a new battery.
Thanks

Posted on Dec 06, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I installed a new battery and then system starts beeping continuously


Hi Anthony,

Is the UPS plugged in? Are there any lit LEDs on the front of the UPS? Did you replace the batteries in while the UPS was plugged in? Make sure that the battery you placed into the UPS is a good battery.

Hope this helps. If you would like more assistance please give me a call: 407.380.9200.

Oct 25, 2013 | APC Smart-UPS 1000VA UPS System

1 Answer

My prostar m ups countinusly beeping and not blink a green signal


Avinash,

More than likely it's a low battery indication. Replace your battery - if you would like pricing reply here or email me using the below information.

Daniel • daniel@psihq.com • Power & Systems Innovations • 800.260.2259 • www.psihq.com

Aug 05, 2013 | APC Smart-UPS 1000VA UPS System

2 Answers

Error light in my apc smart ups sc 1500va ups


1. Four beeps every 30seconds (On Battery LED will be illuminated)
This alarm indicates that the Battery PowerSupplied outlets are now supplying battery power as opposed to power from theutility. If the UPS determines that the input utility power is unsafe for yourcomputer equipment, the UPS will switch to battery power.
Note: Ifthe power disturbance is brief, you may only hear one or two beeps.

2. Continuous Beeping (On Battery LED will beilluminated)
This alarm indicates that a Low Batterycondition has been reached and that the UPS will soon shutdown. Once the UPStransfers to On Battery operation, it can only stay on battery for a limitedamount of time. The UPS will sound this alarm about two minutes before thebatteries are totally exhausted. Once exhausted, the UPS will shutdown and turnoff its output power to your equipment. If you hear this tone you shouldimmediately shutdown your computer to prevent data loss or corruption.

3. Continuous Beeps for 30 seconds (BackUPS OFFICE 250 and 280 ONLY)
This alarm indicates the unit has detected anOverload condition after it has performed a self-test during start-up.

4. Continuous Two-Tone Beep
This alarm indicates a severe Overload wasdetected while the unit was on-battery operation. This tone will continue tosound until the unit shuts down.

5. Continuous Tone (On Battery LED will beflashing)
This alarm indicates that the battery-poweredoutlets are overloaded.

6. Continuous Tone (On Line and On BatteryLEDs flashing) Back UPS OFFICE 350,400, and 500 ONLY
This alarm indicates that an internal UPS faulthas occurred.

Dec 08, 2011 | APC Smart-UPS SC 1500VA UPS System

1 Answer

Red light on front is lit up- beeping- assume it has lost its battery power


You are assuming right. With the UPS on push and hold the on button for 3 seconds. This will start a self test. If the UPS dies then replace batteries

Aug 15, 2011 | APC Smart-UPS 1000VA UPS System

1 Answer

SO bad, and a bad response... I have 2 UPCs one started beeping for no reason, and will not stop...even when plugged into the wall with the battery disconnected... The other one is still silent. SO the...


These beep error codes may help you.
1. Four beeps every 30 seconds (On Battery LEDwill be illuminated)
This alarm indicates that the Battery Power Suppliedoutlets are now supplying battery power as opposed to power from the utility.If the UPS determines that the input utility power is unsafe for your computerequipment, the UPS will switch to battery power.
Note: Ifthe power disturbance is brief, you may only hear one or two beeps.

2. Continuous Beeping (On Battery LED will beilluminated)
This alarm indicates that a Low Battery condition hasbeen reached and that the UPS will soon shutdown. Once the UPS transfers to OnBattery operation, it can only stay on battery for a limited amount of time.The UPS will sound this alarm about two minutes before the batteries aretotally exhausted. Once exhausted, the UPS will shutdown and turn off itsoutput power to your equipment. If you hear this tone you should immediatelyshutdown your computer to prevent data loss or corruption.

3. Continuous Beeps for 30 seconds (Back UPSOFFICE 250 and 280 ONLY)
This alarm indicates the unit has detected an Overloadcondition after it has performed a self-test during start-up.

4. Continuous Two-Tone Beep
This alarm indicates a severe Overload was detectedwhile the unit was on-battery operation. This tone will continue to sound untilthe unit shuts down.

5. Continuous Tone (On Battery LED will beflashing)
This alarm indicates that the battery-powered outletsare overloaded.

6. Continuous Tone (On Line and On Battery LEDsflashing) Back UPS OFFICE 350, 400, and 500 ONLY
This alarm indicates that an internal UPS fault hasoccurred.

Feb 28, 2011 | APC Back-UPS Pro 650 UPS System

1 Answer

The unit beeps


I am getting these directly from the user manual (available here: http://www.apcmedia.com/salestools/ASTE-6Z7VAQ_R3_EN.pdf)

Issue: On Battery - UPS is supplying battery power to the load connected to the Battery outlets.

Visual Indication: Power On LED - ON (off during beep)

Audible Indication: Beeping 4 times every 30 seconds

Stops When: UPS transfers back to Power On operation, or when UPS is turned off.

- OR -

Issue: Sleep Mode - During On Battery operation the battery power has been completely exhausted and the UPS is waiting for utility
power to return to normal.

Visual Indication: None

Audible Indication: Beeping once every 4 seconds

Stops When: Utility power is restored, or if utility power is not
restored within 32 seconds, or the UPS is turned off.


All other issues are CONSTANT tones, which you did not specify, or there are no audible tones associated with it.

Apr 07, 2010 | APC Back-UPS ES 350 - UPS ( external ) -...

1 Answer

When the computer is off or sleep it start the beeps!! Ultra 1000va ups


Do you have a battery backup?Sounds like that's what's beeping.

Mar 03, 2010 | Ultra (ULT31502) UPS System

1 Answer

Strange noise comes out from the ups after a power cut


The Back-UPS Office unit has five different tones or alarms:

1. Four beeps every 30 seconds (On Battery LED will be illuminated)
This alarm indicates that the Battery Power Supplied outlets are now supplying battery power as opposed to power from the utility. If the UPS determines that the input utility power is unsafe for your computer equipment, the UPS will switch to battery power.
Note: If the power disturbance is brief, you may only hear one or two beeps.

2. Continuous Beeping (On Battery LED will be illuminated)
This alarm indicates that a Low Battery condition has been reached and that the UPS will soon shutdown. Once the UPS transfers to On Battery operation, it can only stay on battery for a limited amount of time. The UPS will sound this alarm about two minutes before the batteries are totally exhausted. Once exhausted, the UPS will shutdown and turn off its output power to your equipment. If you hear this tone you should immediately shutdown your computer to prevent data loss or corruption.

3. Continuous Beeps for 30 seconds (Back UPS OFFICE 250 and 280 ONLY)
This alarm indicates the unit has detected an Overload condition after it has performed a self-test during start-up.

4. Continuous Two-Tone Beep
This alarm indicates a severe Overload was detected while the unit was on-battery operation. This tone will continue to sound until the unit shuts down.

5. Continuous Tone (On Battery LED will be flashing)
This alarm indicates that the battery-powered outlets are overloaded.

6. Continuous Tone (On Line and On Battery LEDs flashing) Back UPS OFFICE 350, 400, and 500 ONLY
This alarm indicates that an internal UPS fault has occurred.

Jan 06, 2010 | APC Back-UPS ES 700 - UPS ( external ) -...

3 Answers

Getting red light and continuously beep sound to my UPS(Frontech)


hi

If it is showing the red light and continuous beep it shows that the battery is completely gone.

You can buy a battery and replace it by yourself.

Or get it to a professional to change the battery.

you need not replace the whole UPS its just a battery problem.

Thank you

Aug 10, 2009 | Compaq R1500 ( 295459-001 ) UPS...

Not finding what you are looking for?
UPS Battery Backup Systems Logo

Related Topics:

836 people viewed this question

Ask a Question

Usually answered in minutes!

Top Compaq UPS Battery Backup Systems Experts

all-is-info

Level 1 Expert

7 Answers

Mark Grummell

Level 1 Expert

9 Answers

Jax Planet
Jax Planet

Level 2 Expert

921 Answers

Are you a Compaq UPS Battery Backup System Expert? Answer questions, earn points and help others