With the power off,hold down the "0"&"8" keys while you turn the power on.Then enter the code 400 and change the number showing to a "0". That will reset the error code.

Posted on Dec 04, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Toshiba e studio 225 c41 error comes


C41 is fuser error, enter 08-400 to clear the error, if still persist, check the fuser unit especially thermistor, heater lamp...

Jul 15, 2015 | Toshiba Printers & Copiers

1 Answer

C41 problem for toshiba


It depends on the model but many times the C41 error code is Fusing unit warm-up error, defective thermistor, fusing lamp or thermofuse problems.

Jan 14, 2015 | Toshiba Printers & Copiers

2 Answers

How to fix error c41 toshiba e-sdtudio 18


I am unfamiliar with the e-studio 18 but on other Toshiba e-studio models C41 is a fuser (hot roller) error and it will clear itself when the problem is corrected, there is no reset procedure. I would go back and be sure that the replacement was done correctly.

May 17, 2014 | Toshiba Printers & Copiers

1 Answer

E studio 520 code c447


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0." also 447

Jan 17, 2014 | Toshiba Printers & Copiers

1 Answer

Error code c43


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."

Jan 14, 2014 | Toshiba Printers & Copiers

1 Answer

Call for service C 430


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."

Dec 31, 2013 | Toshiba estudio 255 Copier

1 Answer

C 41 code mean


I suppose the error code is C410.
To clear the error message, perform 08-400 => 0.
If happen again, u need to check the themistor.

Oct 03, 2013 | Toshiba Printers & Copiers

2 Answers

It shows C41 CODE. What s


(C41) Thermistor or heater is abnormal at power ON

You can try going into (08) mode by holding 0 and 8 while turning on the copier. Once the copier starts up key in 400 and press start, input "0" and press interrupt. Try rebooting the copier, if this doesn't clear that call for service then you are going to need to get work done on your fuser.

Sep 27, 2010 | Toshiba e-Studio 35 Copier

3 Answers

Toshiba E Studio 35 error code C41


Hi,

 C41 refers to Poor contact of the fuser drawer connector.
 Fix it!!!!

Apr 16, 2009 | Printers & Copiers

1 Answer

Hello estudio 16 c41


C41 indicates abnormality of the thermistor or heater disconnection when the power is turned on.

U need to check the thermistor and heater lamp.

Jan 18, 2009 | Toshiba e-STUDIO 16 Printer

Not finding what you are looking for?
Toshiba e-Studio163 Copier Logo

Related Topics:

290 people viewed this question

Ask a Question

Usually answered in minutes!

Top Toshiba Printers & Copiers Experts

pkwc

Level 2 Expert

254 Answers

Anthony Chiang
Anthony Chiang

Level 3 Expert

524 Answers

Michel Smith

Level 3 Expert

1218 Answers

Are you a Toshiba Printer and Copier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...