Question about Quintum Tenor A800 (501-0026-00)

1 Answer

Hello, I have a quintum A800. Recently i upgraded its software version from 20 to 40 exactly in the manner it has been described in the quintu website. We after upgrading it ran 20 mins properly and then suddenly it restarted. since then it is continiously restarting. i have tried all type of options with serial cable but nothing is happening. now i cant even get inside the unit. Its only restarting. first it loads the flash, then asks wehther i want to change anything. when i finish setting up, immediately it restarts. Can you give me a solution to this problem ?

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Expert
  • 71 Answers

The software you put is corrupted.. try to delete the flash memory nd install a new one.. but be sure you have a license file befire you do a recovery..


Posted on Aug 25, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Fuji FinePixViewer booting error.


Your operating system is probably outdated for the firmware of the device you are trying to connect. Upgrade.

Dec 21, 2012 | Fujifilm Finepix A900, A825, A820, A610...

1 Answer

I want to confugre Tenor A800 to make SIP


Hi

For making/reciving SIP calls with A800 u need its SIP firmware.
u can add me on MSN for more help.

MSN : hezare3@hotmail.com

Apr 22, 2011 | Quintum Tenor A800 (501-0026-00)

1 Answer

I forget the ip or quintum a800.kindly resolve my issue how do i access the machine.


U can use Console access.
What u need is Hyperterminal + rs232 cable to access A800 via Console.


Hyperterminal can found on all Win OS : Programs > Accessories > Communications

for more help add me on MSN as :MSN:hezare@hotmail.com

Sep 09, 2010 | Quintum Tenor A800 (501-0026-00)

1 Answer

Several problems, please help


try to debug test the line .. maybe one of the line are loose..

Mar 01, 2009 | Quintum Tenor A800 (501-0026-00)

1 Answer

I need quintum CLI configuration manual


pls cq

http://www.quintum.com/support/mgmt/index.shtml

u find GUI configuration software & also CLI Configuration manual

Dec 01, 2008 | Quintum Tenor DX2048 (501012100) 2x10/100...

1 Answer

Can You setup Quntum A800


there is a solution on your problem that already post on this forum.. try to search it..

Nov 26, 2008 | Quintum Tenor A800 (501-0026-00)

1 Answer

I nees to setup Quintum A800 for termination can anyone help me


Command line for termination A800 (Quantum)



Config unit 1# online 1

Config sys# mindn 10

Config sys# maxdn 20

Config pstntg 1# pass 0

Config pstntg 1# cassig 6

Config pstntg 1# super 3

Config pstntg 1# lamp 1 country code (91)

Config pstntg 1# Answerdel 120

Config pstntg 1# lamp 1 9101 01

Config pstntg 1# dis 1 a (ALL - ports)

Config pstntg 1# ena 1 a (ALL – ports)

Config gkadmin allow 1# ip xxx.xxx.xxx.xxx (GW ip + switch-ip)

Config dsp# voice 81 (for g723) voice 68 for (G729)

Config# submit




Local information

Name of this zone Hello
Country selection Canada
Local country code country code (91)
International prefix country code (91)

Hop-off PBX Numbers

91 public

9101 01 public

This configuration for termenation

Nov 20, 2008 | Quintum Tenor A800 (501-0026-00)

1 Answer

Unable to send calls out after a change in the IP address


I hope that you have solved this by now, but the only way to be certain about what exactly happened is by reading event log trace. Your Quintum Reseller should have this knowledge.

Aug 29, 2006 | Quintum TENOR 960 VoIP Terminal Server

Not finding what you are looking for?
Quintum Tenor A800 (501-0026-00) Logo

Related Topics:

291 people viewed this question

Ask a Question

Usually answered in minutes!

Top Quintum Computers & Internet Experts

Les Dickinson
Les Dickinson

Level 3 Expert

18425 Answers

Alun Cox

Level 3 Expert

2678 Answers

David Payne
David Payne

Level 3 Expert

14162 Answers

Are you a Quintum Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...