Question about Fisher and Paykel DEGX1 Electric Dryer

1 Answer

What is demonstation mode and how do I get it off

Demonstation mode is on and I can not turn on to dry

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Fisher and P... Master
  • 2,651 Answers

Demostration mode is for sales man to operate on the showroom for customers, with out actually turning on "heater assy". check your manual in oreder to reset if not contact the toll free cust service number of F&P they are VERY HELPFUL

Posted on Nov 29, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My kenmore elite #110.73012181 electric dryer with autonsense feature no longer sensing, keeps on drying for hours after clothes dry when on less dry mode or normal dry mode


The drying circuit has to have a sensor to control heat and the timer controls time (on timed drying). Often sensors fail "open" and dryers stop drying. This sensor or the circuit seems to have failed closed (runs all the time). I suspect the sensor has failed in the drying control.

Jan 02, 2014 | Kenmore Dryers

1 Answer

How do i reset code e63


your coils in the heating unit are touching the can you will need to clear them probably have to replace a broken porcelin insulator once you do this then you can reset the machine.
factory reset, press and hold the temperature and dry level buttons simultaneously for 6 seconds for models with temperature and dry level and dry time buttons press and hold the drylevel and dry time buttons simultaneously for 6 seconds.
diagnostic mode press the cancel button to enter standby mode and enable diagnostic entry.within 10 seconds after pressing cancel press and button but cancel to wake up the control. within 5 seconds of wake up turnthe selector knob to the far left cycle and press and hold the cancel and the center button under the display simultaneously for 3 seconds to enter the diagnostic mode. upon entering diagnostic mode all lights should flash on and off turn the selector knob clock wise on setting, you will need a book inside the dryer to read the codes pop off the top of the dryer it should be folded down in the front of the machine...

Jul 29, 2012 | Electrolux EIED55H Dryer

2 Answers

I have a Whirlpool Gas Dryer LGR6646BI-12 the clothes feel warm but not hot and they are still damp


The Dryness Level allows adjustment of how damp or dry the clothes are at the end of the cycle.
  1. Make sure the correct Cycle has been selected for the type of fabric being dried.
  2. If the correct cycle is selected and the clothes are still coming out too damp, use the Auto Dry Level button (Kenmore) or Dryness Level button to increase the Dryness level.

  1. If the highest Dryness Level setting was selected and the clothes are still damp, the Customer Focused Drying Mode settings that are built into the machine can be adjusted.
Dryers come from the factory set to Drying Mode 1 (default). Drying Modes 2 and 3, include additional drying time.
Note: This change will affect ALL Auto Dry cycles.
  1. Machine MUST be in Standby mode before beginning. (Standby mode = Plugged in, Power off)

  1. To select drying modes, momentarily press the Auto Dry Level button (Kenmore) or Dryness Level button (Whirlpool) again. The dryer will beep, and the display will flash and show the next drying mode number.
  1. With the door open and the display flashing the desired drying mode number, press the Start button to save the drying mode and exit diagnostics.
  1. Press the Pause/Cancel key at any time to cancel changes and exit from this mode.
Hope this works............

May 01, 2010 | Dryers

1 Answer

Need trouble shooting proceedure to enter self diagnostics for maytag neptune


From the service manual there is more to it but that was all I could put here.
Accessing Service/Diagnostic Mode:
Pressing down the damp dry and time (-) keys
for 5 seconds places the machine in the
diagnostic mode.
SPECIAL TESTS
The following table lists the various tests
available while in the Service Mode, which
can be accessed by pressing the following
keys:
Press Keys Special Test/ Function
wrinkle
release Diagnostic Codes
dryer
temp(^ )
Sequences up the
help/diagnostic code list
dryer temp(v) Sequences down the
help/diagnostic code list
time (-) Displays Software Revision
Number
very dry(< ) View current cycle
temperature (Co)
start/pause
Start or pause cycle running
but remain in Diagnostic
mode
Accessing Diagnostic Codes
After the machine is in the diagnostic mode,
a ‘d’ will display and let the technician know
they are in the diagnostic mode. Pressing the
wrinkle release key will access the diagnostic
codes.The diagnostic codes can be viewed by
using the temperature (^) & (v) keys.
The down arrow key will sequence down the
list one each time it is pushed with no wrap.
The first time the down arrow key is pushed
the display will sequence to the next code
logged. The last code being displayed being
the oldest code. The up arrow will sequence
up the list one code each time it is pushed
until it reaches the top code. If there are no
diagnostic codes available, ‘00‘ will be
displayed for the diagnostic code.
There will be no multiple occurrences of
either a diagnostic code or help code generated
in the same cycle reported on the list.
But if the same code occurs in repeated
cycles, it will be registered.
To clear the diagnostic code list press
wrinkle prevent and very dry (>) for 5
seconds while viewing the list.
System Check Mode
While in diagnostic mode, pressing the damp
dry
and signal (+) keys for 2 seconds, will
put the dryer into the system check mode.
"SC" will display.
This mode will allow the various inputs and
outputs to be controlled and viewed by the
technician by pressing individual keys. If no
activity is seen for 5 minutes after a key is
depressed, the control will reset back to the
normal mode. If no further activity is seen
after an additional 5 minutes the washer will
turn off. The following table lists the various
functions based upon on keys being depressed.
Membrane Pad Check
While in system check mode, pressing the
damp dry and sensor dry keys for 5 seconds,
will start a membrane pad switch test.
The membrane check involves turning all the
embedded LED on the membrane pad on.
All the LED’s can be toggled off by pressing
the key associated with the LED. To exit the
test at any point, press the damp dry (>) &
sensor dry keys again for 5 seconds or press
the off key to exit diagnostic mode.
Key Pressed: Function Performed
sensor dry
Enable sensor dry circuit.
(sense dry LED) When short
circuit is detected across the
sensor bars the normal dry
LED will turn on.
start/ pause
Cycles the motor relay
on/off. When the motor is
running the start/pause LED
is on.
dry temp(^ )
If motor is running, cycles
the heater/gas valve on/off.
When the heater is regular
temp LED is on.
very dry(< ) View current cycle
temperature (Co)
www.appliancehelponline.com

Mar 26, 2010 | Maytag Neptune MDG5500AW Gas Dryer

1 Answer

Fisher & Paykel Dryer model ED56 constant beep


Diagnostic Mode
Entering the Diagnostic Mode
(a) Turn the power supply to the dryer on.
(b) Press and hold the Auto Dry down button, then press the Power
button.
The dryer is now in level 0 of the diagnostic mode. After initial entry into the
diagnostic mode, the Start/Pause button operates the dryer as normal. Press
the Auto Dry up or down buttons to scroll through the fault levels.
There are several levels of diagnostics, most of which are used in
development and production. These levels may bring on various LEDs, but
the level of use for the service technician is that of the last fault.
Last Fault
To enter the last fault diagnostics, enter the diagnostic mode as described
above, then press the Auto Dry up button three times. The last fault will be
displayed on the drying progress LEDs.
The manual is here

Sep 08, 2009 | Dryers

1 Answer

My Fisher paykel dryer does not heat


Thermostat Cutout – Manual Reset (Electrical)
Type SPST 30 Amps/240 Volts AC
Trip Temperature 212°F (100°C)
Diagnostic Mode
Entering the Diagnostic Mode
(a) Turn the power supply to the dryer on.
(b) Press and hold the Auto Dry down button, then press the Power
button.
The dryer is now in level 0 of the diagnostic mode. After initial entry into the
diagnostic mode, the Start/Pause button operates the dryer as normal. Press
the Auto Dry up or down buttons to scroll through the fault levels.
There are several levels of diagnostics, most of which are used in
development and production. These levels may bring on various LEDs, but
the level of use for the service technician is that of the last fault.
Last Fault
To enter the last fault diagnostics, enter the diagnostic mode as described
above, then press the Auto Dry up button three times. The last fault will be
displayed on the drying progress LEDs
Conductivity Contact Impedance Check
To enter the conductivity contact impedance check, enter the diagnostic mode
as described above, then press the Auto Dry up button five times. In this
mode, touching damp clothes or fingers across the conductivity contacts will
cause the LED display to change. If the contacts, or the harness to them,
have gone open circuit, no change will occur in the LED display. This is a
useful method of checking the integrity of the sensor circuits.
To exit the diagnostic mode, press any cycle button.
Entering the Data Download Mode
(a) Turn the power supply to the dryer on.
(b) Press and hold the Auto Dry down button, then press the Power
button. This enters the diagnostic mode.
(c) Press the Regular button.
Encoded data is transmitted serially out the red Auto LED, and is be captured
by an optical download pen attached to a PC where “Smart Tool” software
interprets the data to aid servicing.
To exit, press the Regular button.
Entering the Showroom Mode
(a) Turn the power supply to the dryer on.
(b) Press and hold the Air Dry button, then press the Power button.
The LEDs will flash in a random sequence.
To exit, turn off the power supply to the dryer at the wall.
Tell me what sort of faults codes you can come up with and I will tell you what it means but in the meantime reset the limit and clean out the lint problem, open the stopped up vent. That dryer has to breath or that safety will kick out again. I have the manual

Sep 05, 2009 | Fisher and Paykel DEGX1 Electric Dryer

1 Answer

Dryer will not turn off in Automatic mode


look to a faulty/clogged/blocked vent befoer switching partsno your machine. nost common fault for too long to dry on auto-- or wont advance on auto dry is innadequate venting

Jan 27, 2009 | Dryers

1 Answer

My Whirlpool Dry Model GGQ9858JQ1 turns off in heat mode after a few minutes


HI. thanks for the question. the motor seems to be at fault here. did you clean the venting from the dryer to the outside. , did you clean the lint inside the dryer. if not do that, thanks.

Oct 07, 2008 | Dryers

Not finding what you are looking for?
Fisher and Paykel DEGX1 Electric Dryer Logo

Related Topics:

131 people viewed this question

Ask a Question

Usually answered in minutes!

Top Fisher and Paykel Dryers Experts

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Tim Whalen

Level 3 Expert

3056 Answers

Richard Roth
Richard Roth

Level 3 Expert

9472 Answers

Are you a Fisher and Paykel Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...