Question about Dyna-Glo D-E37 Wall Mounted Panel Heater

1 Answer

Keeping Dyna-glo D-E37 lit

I light my Dyna-Glo Pilot, it stays lit, then I open the valve and the furnace ignites for about 5 seconds and then goes completely out (pilot and all). Can you advise? I'm not sure of the theram couple getting hot enough.

Posted by on

  • Anonymous Nov 29, 2008

    flame lights and burns for a while then the whole thing just shuts off. i can relight the pilot but then again it all shuts off. can't find parts.



1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points


    An expert that got 20 achievements.


    An expert that got 10 achievements.


    An expert that got 5 achievements.

  • Dyna-Glo Master
  • 3,183 Answers

Sound s like the pilot is blocked and the flame is too small or thermocouple needs replacing

Posted on Dec 16, 2008


1 Suggested Answer

  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017


Add Your Answer

Uploading: 0%


Complete. Click "Add" to insert your video. Add



Related Questions:

1 Answer

Why doesn't pilot light stay lit?

either the pilot flame is small or the thermocouple is defective

Jan 15, 2016 | Dyna-Glo D-E37 Wall Mounted Panel Heater

1 Answer

ODS will not stay lit

The pilot generator (aka thermocouple) has gone out. This is the little peg that is mounted close to the front of the burner. The flame heats the thermocouple and it puts out a millivolt current that holds the gas valve open after you release the button. The TC is no longer putting out enough current to hold the valve open.
I beleive the part # is TT15c-11, (about $15)

Dec 14, 2013 | Dyna Glo 18,000 - 30,000-BTU Liquid...

1 Answer

Janitrol GUPS075-3 Furnace burners will not stay lit

The first thing I would do is make sure the flame sensor is clean, this is a metal rod immersed in the burner flame on the opposite side of the igniter. If too much oxidation builds up on it, it will not allow the burner to stay lit. To clean, just turn off furnace and remove flame sensor and clean with steel wool and then reinstall. If this does not solve the problem there may be a problem with the gas valve.

Nov 08, 2012 | Heating & Cooling

1 Answer

The pilot light will not stay lit.

the thermal coupler is bad. That is the piece by the pilot that has a copper line that goes to the gas valve. replace that and it should be fine. hope this helps. have a good day.

Jan 12, 2011 | Dyna Glo "" Natural Gas Heater Mn200tba

1 Answer

I have a Model CGN250TE.The pilot light stays lit but when you turn control valve on it stays lit for 5 seconds and then shuts right down,even the pilot light goes out.I have tried venting the room and...

I would first check the gas pressure to your furnace. Then make sure that burners are clean and watch flames when burner first ignites. I have seen burners that were dirty cause delayed ignition that would create a suction when they came on and extingush pilot and burners.
The next thing I would do is change gas valve. Thank you

Dec 19, 2010 | Williams 2509612 Ceramic Mid-Size Heater

1 Answer

Dyna-Glo model RMC-8000PGH will not stay lit

Your pilot safety is full of dust. Flush it out with shop air or rust buster. Retry


Dec 17, 2009 | Dyna-Glo RMC-8001SS Heater

1 Answer

Dyna Glow pilot light will not stay lit.

there is a screw on the gas valve to adjust the pilot flame . It will be under a cap

Dec 09, 2009 | Dyna-Glo RMC-8001SS Heater

1 Answer

Pilot light on Dyna Glo gas heater won't stay lit

Cleaned pilot light area with an air compressor. Problem solved!

Mar 02, 2009 | Dyna Glo "" Natural Gas Heater Mn200tba

1 Answer

Dyna-glo parts

thermocouples you can buy from any heating spares oulet or national energy a hone well is most common for useing as a replacement

Feb 03, 2009 | Dyna-Glo D-E36 Infra-Red Wall Mounted...

Not finding what you are looking for?
Dyna-Glo D-E37 Wall Mounted Panel Heater Logo

461 people viewed this question

Ask a Question

Usually answered in minutes!

Top Dyna-Glo Heating & Cooling Experts