Question about Air Conditioners

1 Answer

I have a UVB Lamp for my bearded dragon. I thought the lamp needed replacing which I have done. The lamp still does not work so I though maybe the philips S10 ecoclick starter maybe at fault. Do these have a life expectancy? Thanks

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 706 Answers

Hello ja-stead,
EVERYTHING has a life expectancy but that starter may or may not be your problem. If possible, can you take your light fixture to a local pet store to see if they will allow you to try the lamp with the old bulb and new bulb in order to determine if the starter is the problem? You may have some other issue like the switch or wiring to it that is causing the bulb to not illuminate. If you want to 'shotgun' the repair by swapping out components such as the starter, that will eventually lead you to the solution but you may be throwing good money after bad. I am sure that most pet stores will allow you to test it since if it turns out to be the fixture, they will get a sale out of it.. Give it a shot..
Regards,
Rick

Posted on Nov 23, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Daylight running lights work but not headlight on left side


Most likely need new head light lamp as usually there is two or three separate filament in side each head lights lamp and depend on make and model of any vehicles
The most common are head lights lamp with three filament .
One for day light ,one for low beam and last one for high beam

Dec 08, 2013 | Kia 2008 Rondo LX V6

1 Answer

Inverter manuals


Model No Required below Model No AH-X18MEV Self diagnosis mode given

1. Indoor unit
(AH-X18MEV, AH-X18MEV-1, AH-X24MEV, AH-X24MEV-1)
To display the self-diagnosis, hold down the AUX button for over 5 seconds on the indoor unit when the indoor unit is not operating.
• The operation lamp (red), timer lamp (orange) and Super jet lamp lighter) flash to indicate the information of malfunction.
(Display of self-diagnosis result)
The operation lamp (red) and the Super jet lamp (green) flash in synchronization with the timer lamp (orange).
(AH-XP18MV, AH-XP18MV-1, AH-XP24MV, AH-XP24MV-1)
To display the self-diagnosis, hold down the AUX button for over 5 seconds on the indoor unit when the indoor unit is not operating.
• The POWER CONSUMPTION indicator indicates the information of malfunction by showing the main category error (number) and the sub-category
error (-number) alternately in 1-second intervals.
Example: Compressor high-temperature error
Remark
• If the power cord is unplugged or the circuit breaker is turned off, the self-diagnosis memory is lost.
AUX
Operation lamp(red)
Timer lamp(orange)
Super jet lamp(green)

Oct 12, 2013 | Sharp Air Conditioners

1 Answer

Fujitsu ASY12RSE-W. Unit not working at all. Timer lamp blinking & operation lamp flashing twice


It's showing an error code for the outdoor unit no communication from the outdoor circuit board.

Jul 30, 2013 | Fujitsu 24C1 Air Conditioner

1 Answer

It shuts off and blinks 11


AHX18MEV
4 - 12
[8] SELF-DIAGNOSIS FUNCTION
1. Indoor unit
(AH-X18MEV, AH-X18MEV-1, AH-X24MEV, AH-X24MEV-1)
To display the self-diagnosis, hold down the AUX button for over 5 seconds on the indoor unit when the indoor unit is not operating.
• The operation lamp (red), timer lamp (orange) and Super jet lamp lighter) flash to indicate the information of malfunction.
(Display of self-diagnosis result)
The operation lamp (red) and the Super jet lamp (green) flash in synchronization with the timer lamp (orange).
(AH-XP18MV, AH-XP18MV-1, AH-XP24MV, AH-XP24MV-1)
To display the self-diagnosis, hold down the AUX button for over 5 seconds on the indoor unit when the indoor unit is not operating.
• The POWER CONSUMPTION indicator indicates the information of malfunction by showing the main category error (number) and the sub-category
error (-number) alternately in 1-second intervals.
Example: Compressor high-temperature error
Remark

3. CHART
<INDOOR UNIT> ?:1-second ON / 1-second OFF
Problem
symptom
Outdoor
unit indication
(LED1)
Indoor unit Malfunction
No.
Content of diagnosis Check point Action
Lamp Main Sub Main Sub
Normal
condition
Normal
blinking
? ? ? ? ? Timer (Orange) 0 0 Normal
Operation (Red)
Super Jet (Green)
Indoor and
outdoor
units do not
operate.
1-time ? ? ? ? ? Timer (Orange) 1 0 Outdoor unit
thermistor
short-circuit
Heat exchanger
thermistor short
circuit error
(1) Measure the resistance
of the outdoor
unit
thermistors.
(1) Replace the outdoor
unit thermistor
assembly.
? Operation (Red)
Super Jet (Green)
? ? ? ? ? Timer (Orange) 1 Outdoor temperature
thermistor
short circuit error
(2) Check the lead wire
of the outdoor unit
thermistor for torn
sheath and shortcircuit.
(2) Replace the outdoor
unit thermistor
assembly.
? Operation (Red)
? Super Jet (Green)
? ? ? ? ? Timer (Orange) 2 Suction thermistor
short circuit
error
(3) No abnormality
found in above
inspections (1) and
(2).
(3) Replace the outdoor
unit control
PWB assembly.
? Operation (Red)
? Super Jet (Green)
? ? ? ? ? Timer (Orange) 3 2-way valve
thermistor short
circuit error
? Operation (Red)
? ? Super Jet (Green)
LED1
AU-X24MV, AU-X24MEV
AU-X18MV, AU-X18MEV
LED1

May 27, 2012 | Sharp Air Conditioners

1 Answer

OPERATION LAMP AND TIMER LAMP FLASHES . DOESN'T START


Indoor fan motor mechanism locked.Check for power to F.M. if not, replace PCB. If bearing in F.M. replace it. Thanks.

Feb 12, 2011 | Fujitsu 12C1 Air Conditioner

1 Answer

Lucky reptile user manual tc-2uk


Hi I have a tc-2uk therostat for my bearded dragon and wasn't given a manual do you know how to use it?

Oct 12, 2010 | Air Conditioners

Not finding what you are looking for?
Air Conditioners Logo

Related Topics:

75 people viewed this question

Ask a Question

Usually answered in minutes!

Top Air Conditioners Experts

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Bill Long

Level 3 Expert

577 Answers

Tim Whalen

Level 3 Expert

3056 Answers

Are you an Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...