Question about Heaters

1 Answer

The pilot won't stay lit .

When the pilot button is released the pilot goes out, instead of staying on so I can turn the first plaque on on the infra-red heater.

Posted by on

  • Anonymous Nov 30, 2008

    when i try to push the pilot button and release it the flame goes out right away replace the thermo couple and still the same thing took all the tubes of and check for any blockage and still the same thing flame goes out.

×

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

The thermocouple connection had to be tightened securely. i found out that it is an electrical connnection.

Posted on Nov 23, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Furnace Pilot Light Won't Stay Lit


Here is something similar that happened to me. I went through the same steps you went through and upon closer inspection, I found a spider had made a web inside the supply line only letting a small trickle of gas through. Have you verified there is nothing blocking the line?

Oct 02, 2012 | Heaters

1 Answer

When I press down and turn the know the pilot lights but as soon as you let up on the knob to turn it there is a click and the pilot light goes out.. This is on my Mr. Heater Big Buddy


When the pilot lights continue holding the button down for a full minute and then release. It should stay lit then to allow you to turn it to the on position. If the pilot will not stay lit after holding it for the full minute, then the thermocouple will need to be replaced.
Hope this helps.

Sep 16, 2011 | Mr. Heater Big Buddy Heater

1 Answer

Pilot don't stay lit after the gas control knob is release.


Hi,
The thermocouple is bad and you will have to replace it...
The thermocouple is the thing that sticks up in the flame to sense that the flame is on... if it goes bad the pilot flame will not stay lit when you release the button...

heatman101

Dec 05, 2010 | Williams 3501922 (NG) Gas Compact Heater

1 Answer

How do i light pilot light?


Remove front cover,or just lower section if you can. they usually just need to be lifted up about an inch or so and pulled out. However some have covers that snap in place. After you remove cover locate gas valve. It should have a control knob on top with markings for on, off, and pilot. Set control to pilot. Follow lines from gas valve to burner compartment, one goes to main burner one ,small copper colored line is the thermocouple, other line is the pilot. Turn thermostat down as far as it will go. Make sure gas supply valve in line to heater is on and then depress pilot control , when you have pilot control depressed have a match or other small flame source close to pilot assembly. If it lights then hold down on pilot control for a couple of mins. Slowly release pilot control and if it stays lit turn gas control to on. Turn thermostat up to call for heat and burner should light. If pilot doesn't stay lit when you release pilot control then try again holding pilot down longer. If it still won't stay lit then thermocouple will need replace. Good luck. Thanks

Nov 22, 2010 | Williams 6508732 Gas Heater

1 Answer

My intertherm mgha is having pilot issues. The


The problem will be in what senses the pilot is lit. Either a thermocouple or maybe it uses an electrode and flame rectification. If it is an electrode you can try cleaning it. If it is a thermocouple you will have to replace it.

May 02, 2010 | Heaters

1 Answer

Pilot will not stay lit and heater will not light


thermocouple probablly bad, is the flame covering the thermocouple.
the flame has to hit top portion of thermocouple to work correctlly.

Feb 14, 2010 | Endless Summer (GA200209) Stainless Steel...

1 Answer

Pilot wont light


If the pilot light goes out when you release the primer,then the thermocouple is bad.You can try to adjust the thermocouple,if it can be.It needs to be in the pilot flame.If the thermocouple is not in the flame,it will not stay lit.If you can not get the pilot to light at all,with the primer pushed down,then replace the regulator.To light the pilot light,you need to turn the dial to pilot.Then press the primer button down and hold it.The primer is either built into the turn knob,or it is a res button.Hold the primer down,and light the pilot,continue holding the primer down for at least 40 seconds.Then release the primer slowly,and if the pilot light starts to get weak,and try to go out,then push back down,and hold 30 seconds more.After the pilot stays lit,turn the knob to furnace or low,or whatever the directions say.

Oct 19, 2009 | Heaters

1 Answer

I HAVE A DESA LP VENTLESS FIREPLACE AND THE PILOT WILL NOT STAY LIT


the heater makes use of a millivolt generator which generates a small dc voltage (500-750mv) that is applied to the pilot valve of your main gas valve. when you light your pilot, the flame bathes the generator with a flame. after a delay you release the pilot button. if the generator is working, the pilot valve will stay lit. if the generator is not working the flame will go out as soon as you release the pilot button. change the generator.

Oct 13, 2009 | Desa International Heaters

Not finding what you are looking for?
Heaters Logo

Related Topics:

123 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heaters Experts

paulcarew

Level 3 Expert

1898 Answers

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Mack Baxter

Level 3 Expert

379 Answers

Are you a Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...