Question about Pride Jazzy 1113 ATS Indoor Power Wheelchair

1 Answer

Controller Fault Error 1113 Programmable Controller

The controller fault indicator is flashing on my 1113 programmable controller. I guess 'll need a new one. My question is will a standard VS-1 Jazzy controller work. If so do I need to make any changes to the base electronics. Thanks in advance for any help.

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Contributor
  • 32 Answers

Yes

Posted on Apr 03, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

When turning on my jazzy 1113 ats the first four lights in the battery strength blink rapidly, chair wont go


4 flashing lights fault code tells you that the right motor has a bad connection. Check and make sure that the right motor is engaged and that it is plugged in properly. The code says that the wiring to the right motor or the right motor itself is bad. The fault codes aren't always right and it could be a problem in the joystick controller itself.

Nov 24, 2014 | Pride Wheelchairs

1 Answer

Code 3101 Bridge voltage fault what is the fix?


The VSI controller (the unit that contains the joystick) may have gotten wet. If you can take it apart and dry it out it may fix it. That has worked for me. Most times, I wound up replacing the controller. Rebuilds seemed to work fine and were much less expensive.

Sep 02, 2014 | Pride Jazzy 1113 Power Chair

1 Answer

Controller arm has loose wires


That controller is expensive and needs to be reprogrammed after repairs. I'd let a service and repair center do the work. You just can't jump in and fix it yourself without that programmer.

Feb 03, 2014 | Pride Jazzy 1113 Power Chair

1 Answer

Have a jazzy chair purshased from scotter store. error code flashes 8 times. cant get anyone to come look at it what do i do?


If you have a GC Controller 8 flashes indicate a control system fault. Check all connections - especially connections to power module and joystick.

Apr 19, 2013 | Jet 3 Ultra Power Chair

1 Answer

My Drive Cirrus Plus power wheelchair doesnt move, it flashes the first two LEDs in red and when moving the joystick it won't move or make the sound. What could be wrong? The battery is at full charge


The Drive Cirrus Plus power wheelchair is a folding frame chair with a VSI controller. The VSI controller (joystick) will indicate a fault code when it detects a problem with your power chair. It is manufactured by a company called Penny Giles Drive Technology. An LED flash code of 2 on the battery display indicates that the left motor is disconnected. There may be a brake fault also.

The left motor can be disconnected at the plug where the VSI harness plugs into the motor plug. The pins for the motor or VSI output may be pushed back in the connector or not making contact due to corrosion or dirt. Unplug this connector and inspect the pins and make sure they are making good contact and are clean. Spray contact cleaner on the contacts to clean or re-orient the pins to make better contact. The folding frame of the chair may have dislodged the connector. The wiring harness from the motor may be pinched or cut. The brake wires and pins may have become disconnected also. The brake lever may be in the disengaged freewheel position causing a fault, so put the brake lever in the correct position. Strictly speaking, this fault code is for the motor only, but always check the motor/ brake assembly since the wiring runs from the same plug.

A certified technician will have a hand held programmer to read the computer (VSI) fault log and determine the number of error codes for the various components.

Using a digital voltmeter you can check the motor at the plug. The two large wires on this 4 pin plug go to the motor; the two small wires go to the brake. On the resistance scale the motor should read between 0 and 1.6 ohms. The brake should read between 30 to 60 ohms.

There is a chance that the output of the VSI controller is bad. To test this swap the left and right motor output connectors from the VSI. If the error code now indicates right motor disconnected (flash code 4) you have a good VSI and bad left motor. Swap the leads back after you are done with this test.

Try blocking up the chair and see if the motor runs with no load on it or after spinning the drive wheel by hand. You can also inspect the motor brushes for burning and wear. If you pull the brushes, do this carefully and blow out the dust from the motor armature. This may allow the motor to work again for a short time.

You will probably need to hire a technician if, after checking for bad connections and the brake lever in the wrong position, you still have problems. I like to replace the brake/ motor/ gearbox as a complete assembly to avoid future problems. Labor for the diagnosis and reading the fault code log with a hand held programmer should be under 1 hour. A return visit to replace the motor brake gearbox is under 1 hour. Hope this helps.

Dec 25, 2010 | Drive Medical Cirrus Plus Folding Power...

1 Answer

I have invacare pronto m51 with surestep the spjis flashing 9 times what is the problem


The 9 flash error code indicates a communications fault. The communication fault relates to the communication between the joystick and the control module. The joystick on the arm mount is connected to the control module in the base. When there is a break in the wiring of this wiring harness, also called a bus cable, a fault occurs. This trips the computer and the computer sends out a flash code to the joystick. Simply stated there is a broken or pinched wire between the joystick and controller. Look physically at the wire and check for cuts, breaks or pinches. The best short term repair is to repair the broken wire with solder and heat shrink or tape. You can also use **** splice connectors and tape. The best long term repair is to replace the harness with a part available from Invacare. The most definitive way to diagnose this problem is to read the fault log of the controller using a hand held programmer available to dealers and certified technicians. The number and type of fault codes logged in the controller is another indicator of which
component(s) has failed. Hope this helps.

Nov 19, 2010 | Invacare Pronto M51 Power Wheelchair

2 Answers

All lights are flashing, and chair won't move when I try to use


The flash codes for the VSI controller used on this chair are located here:
http://www.pgdt.com/scenter/diagnostics/diagvsi.html
These will tell you what the fault is; repost with more information.

May 23, 2010 | Pride Jazzy 1113 ATS Indoor Power...

1 Answer

Jazzy 1113 ATS Indoor Power Wheelchair: the battery is fully charged but it wont move does...


Hi. Your machine probably has a fault, but I very much doubt that it needs reprogramming.
Are the free-wheel levers in the correct place? Is the machine displaying any fault codes, e.g. flashing LED's and what is the pattern or number of flashes between pauses?
Good luck. Neil.

May 16, 2010 | Pride Jazzy 1113 ATS Indoor Power...

1 Answer

Go to turn the power on the controller of a Jazzy 1143. The lights on the controller flash and no power goees to the chair. Have checked all connections and still nothing works.


Flashing lights indicates a fault. Here' the users manual which contains the fault codes for the flashing lights. Repost with more info re: the fault codes. Good Luck.
http://www.pridemobility.com/pdf/Owners_Manuals/US_Jazzy/US_Jazzy_1143_om.pdf

Also, make sure the charger is not plugged into the chair.

Jun 06, 2009 | Pride Jazzy 1113 Power Chair

Not finding what you are looking for?
Pride Jazzy 1113 ATS Indoor Power Wheelchair Logo

Related Topics:

373 people viewed this question

Ask a Question

Usually answered in minutes!

Top Pride Wheelchairs Experts

Colin Taylor

Level 2 Expert

340 Answers

wcdoc1953
wcdoc1953

Level 2 Expert

269 Answers

yadayada
yadayada

Level 3 Expert

61249 Answers

Are you a Pride Wheelchair Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...