On display I get "SC556 turn off and on. If error recurs call service."When I do this the message is still there. Any idea what this error code means (apart from get a new printer!)ThanksMartin
SC 556 Pressure roller fusing lamp temperature fluctuation
The pressure roller
temperature changes by
±20°C or more in one second.
This occurs three times in one
minute or two consecutive
times.
• Loose connection of
the pressure roller
thermistor 1. Check if the fusing unit is properly set
and connected to the main frame.
• Loose connection 2. Check if the pressure roller thermistor
connector is firmly connected.
between the fusing
unit and main frame
3. Replace the fusing unit.
800 views
Usually answered in minutes!
×