Ptac unit not heating, but fan,thermostat switch and ac is working. Please advise the solution to the problem. Thank you.

Posted by on

  • garyl322 Nov 16, 2008

    To hvacman1969, my amana ptac unit is model# pth153b35ae. Thank you for your support.

×

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Contributor
  • 31 Answers

Sounds like your control board could be bad,I'm a master a/c tech I work on these from time to time and I have more problems with the control boards,what brand is it

Posted on Nov 16, 2008

  • jim Nov 18, 2008

    is this ptac unit have a digital readout

×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Problem with GE PTAC-Model# AZ28E09DABM2 - Why won't condenser kick on when switching to AC from Fan. AC was working fine until today...Fan is still working...Pulled the unit out and could feel the h


Hummm. A bit difficult to solve this problem. Seems like the condenser outside is not working, I mean the fan of the condenser. Looks like you have a wall A/C and a wall A/C always have condensers outside the house and near the A/C. Have you checked if the fan is spinning? I don't think the compressor is at fault but check it anyway. You should be able to hear the compressor running either in the wall unit or in the outside condenser housing. The only heat you should feel is from the condenser itself. If you blows warm air, that means the fan is working, if not that means the fan is not working. But don't be confused with the fan not working because in winter time sometimes the fan is not working and some times it does. As I said, it's a difficult problem to solve but at least start with checking the situation with the fan in the condenser.

Jun 16, 2014 | GE Zoneline Deluxe Series Cooling &...

1 Answer

No fan when ac kicks on Ihave a eb15b funace with a coleman ac


The heat will normally use a low speed on the fan, & the AC along with the fan switch on the thermostat will use the high speed. The thermostat turns that high speed on when there is a call for cooling & is the same switch if you were to manually turn the fan from auto to on. Try turning the fan on @ the thermostat. If it works, then replace your thermostat. If it doesn't, it could be a bad fan speed, a bad fan relay on a control board or external relay, or a loose or broken green thermostat wire.

Apr 14, 2014 | Coleman Home Electric Furnace Eb15b/Eb15d

1 Answer

We have the white and rodgers thermostat model 1F81-261. The problem is that the ac unit will not work. We have reset and changed the batteries and set the point 4 degrees less than the actual room...


Set System Switch to Cool and lower setpoint below room temperature.
Verify thermostat and system wires are securely attached.
Diagonistic: Set System Switch to Cool and lower the setpoint below the room temperature. Within a few seconds the thermostat should make a soft click sound. This sound usually indicates the thermostat is operating properly. If the thermostat does not click, try the reset operation ( . If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the furnace manufacturer or a service person to verify the heating system is operating correctly.

Reset the thermostat by pressing , UP,DOWN and TIME at the same time.

Jun 28, 2010 | White Rodgers White-Rodgers 1F85RF-275...

2 Answers

I'm not getting heat from my unit..


the compressor is controled seperately from the fan, this is done with the thermostat, try turning the thermostat on then of or untill you hear the "click" sound from the thermostat. If the compressor is still not turning on this may be more than you can fix if your not familiar with electrical hvac troubleshoting... more than lilkely the thermostat may be bad, or your compressors starting components are failing...if the compressor is comming on when the unit is turned on you could have a freon leak causing no heat. hope this may help some there is just too much to write on the causes this will give you a start though!!

Jan 17, 2010 | Amana PTC153B50AM Split System Air...

2 Answers

Will not switch to cool mode. heat and fan work fine


hi,
regarding on switch mode theres a common line between heating and cooling although fan is always connect on them.,also with the thermostat,the sequence on this when you switch to cooling and your connection is on heater,the contactor will shift to compressor source,so if there is no cooling, the contactor supplying the compressor is not functioning when you switch on cool mode.try to tighten screw on compressor relay maybe only loose.on control panel,or check continuity of compressor if the compressor still good,check also the freon charge using clamp ammeter,this should be done by ac technician.have a nice day
rate me up,thank's

Apr 26, 2009 | Heating & Cooling

1 Answer

LG PTAC acting strange in heat mode


I believe the problem in lies in the dual stage heat mode setup on the thermostat, but the unit going into defrost does make the unit act kinda strange. Even more so than other types of equipment. I would suggest hiring a licensed HVAC service technician if the problem cannot be resolved by yourself.

Dec 15, 2008 | LG LP120HED Wall/Window Air Conditioner

3 Answers

2 problems.. AC Comp cuts out. And Fan will not stop.


Unit#2 -Sounds like the contacts on the master switch are welded closed or the switch is broken, Replacing the switch should fix this unit.
#1 is a little more difficult to diagnose. The compressor is being taken off line by a circuit that protects the compressor from damage either; 1- liquid refrigerant getting back to the compressor which can be caused by something as simple as a clogged return air filter or evaporator coil on a heat pump or 2- overload situation caused by a bad condenser motor or a clogged condenser coil. The first thing you need to do is clean both coils and replace the filter,. Then check to be sure your getting good airflow across both coils. I think it's most likely an airflow issue I hope this resolves the problem GL!

Jun 11, 2008 | Amana PTH123B25AJ Heat Pump Air...

3 Answers

Ptac fan keeps blowing


Try setting the fan control to "AUTO" this will cause it to cut out with the compressor.

May 02, 2007 | Amana PTH123B25AJ Heat Pump Air...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

315 people viewed this question

Ask a Question

Usually answered in minutes!

Top Amana Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Donni Steen

Level 3 Expert

659 Answers

Bill Long

Level 3 Expert

587 Answers

Are you an Amana Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...