Question about Haier Air Conditioners

1 Answer

Pilot not turning on - Haier Air Conditioners

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Contributor
  • 31 Answers

DO YOU HAVE STANDING PILOT LIT ALL THE TIME OR A ELECTRONIC IGNITION SPARK BOX

Posted on Nov 16, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

When i unplug my rinnai heater does that turn off the pilot light?


If it's a Vent-free (Vent-less) heater, not it does not turn OFF the pilot light. If it is a Vented Heater, yes unplugging the heater will turn the pilot light OFF. If you want to turn the pilot off on either unit, the best way to do it is with the Gas Valve, Pilot Control Knob. Turn the knob from the ON position counterclockwise to the OFF position and the pilot flame will go out.

Hope this helped you.

Apr 09, 2011 | Air Conditioners

1 Answer

My screen is out on my chimney flute, a bird was trapped inside and worked it's way to the furnace and was killed there. The bird has been removed, now the furnace is not producing airflow throughout the...


The pilot is iside the burner compartment of the furnace. Remove the cover and follow the 1/8" tubing to an orifice. This is where you light the pilot. the gas valve must also be turned off for a couple of minutes before trying to light the pilot. After a few minutes, turn the valve to pilot and light the pilot. Hold it for 30 seconds and then turn the valve to "ON"

Jan 26, 2011 | Air Conditioners

1 Answer

Hi there i recently had another gas appliance installed and the gas was turned off while this work was done, so my hot water service pilot light went out. the guys who did this work didn't relight the...


First turn the dial on the hot water heater to the off position and wait for 5 minutes. Then turn the dial on the water heater to the pilot position. Press in the dial and use a gas grill lighter, long wooden match, or similar device to light the pilot. Once the pilot is lit, continue to hold in the dial for about 1 minute then release and turn the dial to the temperature setting that's comfortable for you.

Dec 11, 2010 | Air Conditioners

1 Answer

Im calling for heat from the thermastat and control panel, the boiler light and and the fan is running, but no matter how many times i keep re trying the pilot and burner will not commence, is there...


I would check to make sure control on gas valve is in on position and pilot is lit if you have a standing pilot. If you have a spark or hot surface ignitor make sure they are trying to lit pilot. If you have standing pilot model and pilot lit is not on. Turn control on gas valve to off,wait five mins. then turn to pilot. Depress botton and try to light pilot. If it lights hold down for a couple of mins. then release.. If pilot stays lit turn control to on. If thermostat is calling for heat this should bring main burner on. If pilot does not stay lit then replace thermocouple. Hope this helps. Thanks

Nov 16, 2010 | Air Conditioners

1 Answer

We have an older (22 years?) 'Insta-Flame (model HE30 TN) natural gas fireplace insert. The pilot light is out, as we painted to inside of the firebox. The instructions show to 1) turn the dial to 'off'',...


On some gas valves the pilot setting is on the same dial as pilot on and on .on others the pilot light has aseperate button on right side of control dial. If yours has this there will be a cut out on cotrol dial that must be aligned with button to allow it to be depressed to light pilot. If yours has this align control dial cutout with pilot button,depress button and light pilot,hold for about one min. and slowly release,if pilot light stays lit,turn down thermostat and rotate control dial normally to right . There should be arrows or marks on dial and gas valve to line up. If pilot light stays lit turn dial to next position and check to see that pilot is still lit. This should be on position, turn up thermostat and burner should light. If your dial has pilot light setting on it then rotate dial to each position,try to depress dial and when you have right one dial will depress allowing you to light pilot. Follow same procedure as above and you should be in business. Hope this helps.Thank you

Nov 11, 2010 | Air Conditioners

1 Answer

Why would the pilot light ignite then turn off?


If it is a true "pilot" light, it needs to be held down long enough to generate the milivolts needed to prove to the gas valve that he is ready to open, other wise the gas valve would open, not igniting, thus causing a "gas leak". Turn the t-stat OFF, turn gas valve to pilot, push down on pilot knob, light pilot and hold for 2 minutes. After 2 mins let go, and if pilot stays lit, turn gas valve to ON, and turn the stat to heat and turn it up to desired temp. If pilot does not stay lit after doing above, try sanding thermo couple( the thing the flame is sitting in) or just spend the $15 bucks and replace therm couple. azeddysac@yahoo.com

Nov 06, 2010 | Ruud UAPA024 Air Conditioner

1 Answer

I HAVE A 20+ BRYANT BOILER THE PILOT LIGHT IS OFF HOW DO I TURN IT BACK ON PLEASE HELP THANKING YOU IN ADVANCE MS I


Turn the gas valve to pilot. Push knob down & hold. While holding, light pilot & keep knob held down for one minute. Let go of knob & see if pilot stays lit. then turn knob to on position. Boiler should then turn on.

Oct 18, 2010 | Bryant Air Conditioners

1 Answer

Heating isn't working, can't find the red button to relight the pilot


Many times the knob to turn the gas on on the valve is also the pilot knob. Turn it to pilot and hold it down while you light the pilot. Hold it for up to a minute and release. If the pilot stays on then turn it to on. If not you need a new thermocouple.

Apr 26, 2009 | Air Conditioners

1 Answer

The heater in my central heating is not getting turn on but the fresh air and cooling is getting turn on


Check the pilot light.Older standing pilot systems use thermocouples to verify the pilot is burning before the gas valve opens.If the pilot wont stay lit replace the thermocouple.
Newer systems light the pilot.On a call for heat the igniter lights the pilot. When the heat is verified the gas valve opens . Some systems use an circuit board with flashing led lights to help troubleshooting.

Jan 11, 2009 | Air Conditioners

1 Answer

Need to know how light pilot


First step turn the thermostat off. It is very important.
Next find the knob on top of the gas valve you will see writing on it turn it to pilot it could be in the off position so move it to pilot depress the knob where it goes down about one inch. Take a long lighter long match or something like that and hold at the pilot it will be back in the furnace by the front of the burners. Once the pilot lights hold the button for another 30 seconds. Release the knob now the pilot should be on and the next step is why you turned off the thermostat rotate the knob to on position. Go to the t-stat and turn on the heat.

Nov 27, 2008 | Air Conditioners

Not finding what you are looking for?
Air Conditioners Logo

Related Topics:

30 people viewed this question

Ask a Question

Usually answered in minutes!

Top Haier Air Conditioners Experts

Cindy Wells

Level 3 Expert

4754 Answers

ask_not

Level 1 Expert

28 Answers

yadayada
yadayada

Level 3 Expert

60769 Answers

Are you a Haier Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...